Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

×
High Resolution Image

Mean Well HLG-480H-42A Power Supply 480W 42V - Adjustable

premium quality, 7 years warranty, aluminium casing, high efficiency

|

Description

Features

Constant Voltage + Constant Current mode output
Metal housing with Class I design
Built-in active PFC function
Environment-adaptive driving capability
IP67 / IP65 design for indoor or outdoor installations
Function options: output adjustable via potentiometer; 3 in-1 dimmings (dim-to-off and Isolated Design); Smart timer dimming; Low-temperature light-on; Junction box
Typical lifetime >62000 hours
7 years warranty(Note.9)

General Specification 

AC input voltage range 90~305VAC | 127~431VDC
AC inrush current (max.) COLD START 35A(twidth=1800 s measured at 50% Ipeak) at 230VAC; Per NEMA 410
Short Circuit Protection Constant current limiting recovers automatically after the fault condition is removed
Over-voltage protection Up to 129% | Shut down output voltage, re-power on to recovery
Over temp. protection Shut down output voltage, re-power on to recovery
Setup, rise, hold up time 500ms, 80ms 115VAC/230VAC
Withstand voltage I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
Working temperature -40~+90ºC (refer to output derating curve)
Safety standards UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384; GB19510.14,GB19510.1;IP65 or IP67, EAC TP TC 004,AS/NZS IEC 61347.2.13:2013,AS/NZS 61347.1:2016;KC61347-1, KC61347-2-13(except for AB,Dx,D2-type), J61347-1(H29), J61347-2-13(H29)(for Blank/A-type) approved
EMC standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
Dimension (LxWxH) (mm) 262 x 125 x 43.8mm
Packing 2.8Kg;4pcs/12.2Kg/0.55CUFT

Specifications

  • Brand
    Mean Well
  • Series
    HLG Series
  • Power Rating
    480 Watt
  • Output Voltage
    42 Volt
  • Rated Current
    11.4 Ampere
  • Input Voltage
    90V~305V
  • Standards Met
    CB,CCC,CE,EAC,PSE,RCM,TUV,UL
  • Operation Mode
    Constant Current,Constant Voltage
  • Operating Temperature
    -40°C~90°C
  • Warranty
    7 Year
  • Length
    26.2 cm
  • Width
    12.5 cm
  • Height
    4.38 cm
  • Weight
    2.8 kg

File Downloads

::specification::

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8423728677163, "variants" :[{ "context":"default", "variant_id": 45635545760043, "sku":"HLG-480H-42A", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_identity\/redirect?locale=en\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HLG-480H-42A Power Supply 480W 42V - Adjustable
Mean Well

Mean Well HLG-480H-42A Power Supply 480W 42V - Adjustable

Features

Constant Voltage + Constant Current mode output
Metal housing with Class I design
Built-in active PFC function
Environment-adaptive driving capability
IP67 / IP65 design for indoor or outdoor installations
Function options: output adjustable via potentiometer; 3 in-1 dimmings (dim-to-off and Isolated Design); Smart timer dimming; Low-temperature light-on; Junction box
Typical lifetime >62000 hours
7 years warranty(Note.9)

General Specification 

AC input voltage range 90~305VAC | 127~431VDC
AC inrush current (max.) COLD START 35A(twidth=1800 s measured at 50% Ipeak) at 230VAC; Per NEMA 410
Short Circuit Protection Constant current limiting recovers automatically after the fault condition is removed
Over-voltage protection Up to 129% | Shut down output voltage, re-power on to recovery
Over temp. protection Shut down output voltage, re-power on to recovery
Setup, rise, hold up time 500ms, 80ms 115VAC/230VAC
Withstand voltage I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
Working temperature -40~+90ºC (refer to output derating curve)
Safety standards UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384; GB19510.14,GB19510.1;IP65 or IP67, EAC TP TC 004,AS/NZS IEC 61347.2.13:2013,AS/NZS 61347.1:2016;KC61347-1, KC61347-2-13(except for AB,Dx,D2-type), J61347-1(H29), J61347-2-13(H29)(for Blank/A-type) approved
EMC standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
Dimension (LxWxH) (mm) 262 x 125 x 43.8mm
Packing 2.8Kg;4pcs/12.2Kg/0.55CUFT