Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PM-20-12 is the 12V output model of this series: rated current 1.8A, rated power 21.6W, typical efficiency 81%.
Features
- Universal AC input / Full range
- Low leakage current <300μA
- Protections: Short circuit / Overload / Over voltage
- Ultra-miniature size, light weight
- Cooling by free air convection
- Medical safety approved (2 x MOPP between primary to secondary)
- No load power consumption<0.75W
- 100% full load burn-in test
- Fixed switching frequency at 90KHz
- High reliability
- Suitable for BF application with appropriate system consideration
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 1.8A
- CURRENT RANGE
- 0 ~ 1.8A
- RATED POWER
- 21.6W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 500ms, 20ms/230VAC 500ms, 20ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 15ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 440Hz
- EFFICIENCY (Typ.)
- 81%
- AC CURRENT (Typ.)
- 0.6A/115VAC 0.4A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 30A/115VAC 65A/230VAC
- LEAKAGE CURRENTNote.6
- Earth leakage current < 300 μA/264VAC , Touch current < 100μ A/264VAC
PROTECTION
- OVERLOAD
- Above 105% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 13.8 ~ 16.2V Protection type : Shut off o/p voltage, clamping by zener diode
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +60℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1, EAC TP TC 004 approved
- ISOLATION LEVEL
- Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP
- WITHSTAND VOLTAGE
- I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to EN55011(CISPR11),EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to EN61000-4-2,3,4,5,6,8,11, EN55035, EN60601-1-2, EN61204-3, medical level, EAC TP TC 020
OTHERS
- MTBF
- 487.8Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 94*56*22.7mm (L*W*H)
- PACKING
- 0.18Kg; 90pcs/17.2Kg/0.94CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
- 5. Touch current was measured from primary input to DC output.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the PM-20-12 for a 12V PLC accessory or control circuit?
Yes, it is a constant-voltage 12V supply rated for 1.8A and 21.6W. It fits small 12V control and automation loads as long as the total requirement stays within 1.8A and 21.6W.
Is the PM-20-12 suitable for 12V sensors, relays, or monitoring hardware in industrial equipment?
It can be used with 12V sensors, relays, and monitoring electronics that require regulated 12V DC. The available output is 1.8A, with a maximum of 21.6W.
Can this model power a small 12V embedded or automation subsystem?
It is intended for constant-voltage 12V applications, so it can support small embedded or automation subsystems designed for 12V input. The connected load must remain within the 21.6W and 1.8A output limits.
Is the PM-20-12 intended for indoor or outdoor environments?
The operating temperature range is -20°C to +60°C, which defines its temperature envelope. No IP rating is listed in the specs, so the product data does not indicate protection for outdoor exposure or wet locations.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other PM-20 Models
3 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well PM-20-5 Power Supply 20W 5V 4.4A | 22W | 5V | 4.4A | View |
| Mean Well PM-20-3.3 Power Supply 20W 3.3V 4.5A | 14.85W | 3.3V | 4.5A | View |
| Mean Well PM-20-24 Power Supply 20W 24V 920mA | 22.08W | 24V | 0.92A | View |