Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well SD-1000L-48 DC-DC Converter - 1000W - 19~72V in 48V out 21A
Overview
SD-1000L-48 is the 48V output model of this series: rated current 21A, rated power 1008W, typical efficiency 90%.
Features
- 1U low profile 41mm
- High power density 10.7w/inch³
- 2000VAC I/O Isolation
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Output OK signal
- Built-in remote ON-OFF control
- Built-in remote sense function
- Forced air cooling by built-in DC fan with fan speed control
- 12V, 0.25A auxiliary output
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 21A
- CURRENT RANGE
- 0 ~ 21A
- RATED POWER
- 1008W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 46 ~ 60V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 500ms, 50ms at full load
INPUT
- VOLTAGE RANGENote.5
- 19 ~ 72VDC
- EFFICIENCY (Typ.)
- 90%
- DC CURRENT (Typ.)
- 23.5A/48VDC
- INRUSH CURRENT (Typ.)
- -----
PROTECTION
- OVERLOAD
- 105 ~ 125% rated output power Protection type : Constant current limiting, unit will shut down o/p voltage after about 5sec. Re-power on to recover
- OVER VOLTAGE
- 62 ~ 68V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- REMOTE ON/OFF CONTROL
- Please refer to function manual
- OUTPUT OK SIGNAL
- Open collector signal low when PSU turns on, maximum, sink current :10mA
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +60℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.02%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- IEC62368-1 CB approved by TUV, TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32), EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,6,8, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 898.2K hrs min. Telcordia SR-332 (Bellcore) ; 106.7K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 295*127*41mm (L*W*H)
- PACKING
- 1.94Kg; 6pcs/12.6Kg/1.15CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 48, 96VDC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the SD-1000L-48 for 48V telecom or network equipment fed from a wide DC input range?
Yes, it provides a constant 48V output and accepts a listed 19-72V input range. With 1008W output power and 21A output current, it is sized for higher-power 48V DC equipment.
Is the SD-1000L-48 a fit for 48V industrial automation systems?
It can be used where the load requires regulated 48V DC at up to 21A. The 1008W rating makes it more appropriate for larger 48V automation loads than for low-power control devices.
Can this model support 48V embedded or communications hardware from vehicle or battery-based DC systems?
It is intended for DC conversion applications that need 48V output from a source within the listed 19-72V range. The converter operates in constant voltage mode and is rated for up to 1008W.
Is the SD-1000L-48 suitable for outdoor enclosures or harsh temperature swings?
The specified operating temperature range is -20°C to +60°C, so use should stay within that range. No IP rating is listed in the product data, so the specs do not identify it as an outdoor-rated converter.
How does the SD-1000L-48 compare with the other SD-1000L versions?
Within the SD-1000L series, the SD-1000L-12 is 720W at 12V and 60A, the SD-1000L-24 is 960W at 24V and 40A, and the SD-1000L-48 is 1008W at 48V and 21A. The choice between them is based on the required output voltage, current, and total power.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.