💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well DDR-480B-24 DC-DC Converter - 480W - 16.8~33.6V in 24V out 20A

2:1 or 4:1 wide input rangefanless design4KVdc I/O isolationultra slim dimensions
SKU DDR-480B-24
Log in to see price Trade pricing & online ordering for account holders
Model

Select model — 16 in this family

DDR-480B-24
Available to order
|

Overview

DDR-480B-24 is the 24V output model of this series: rated current 20A, rated power 480W, typical efficiency 91%.

DDR-480 series is a 480W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, ultra slim width (85.5mm), 2:1 wide input voltage, fanless design, -40~+80℃ wide operating temperature, 4KVdc I/O isolation, 150% peak load, current sharing, DC OK, adjustable output voltage and full protective functions. This series of models has various input options: 16.8~33.6V / 33.6~67.2V / 67.2~154V and multiple output options: 12V / 24V / 48V and can be used for industrial & railway control, security control, communication system and other fields. Suitable applications include to DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable...etc.

Features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • Width only 85.5mm
  • 2:1 wide input range
  • -40~+80℃ wide operating temperature
  • 150% peak load capability
  • Current sharing up to 1920W(3+1)
  • DC output adjustable
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Protections: Short circuit / Overload / Over voltage / Over temperature / Input reverse polarity/ Input under voltage protection
  • 4KVdc I/O isolation(Reinforced isolation)
  • DC OK relay contact
  • Remote ON-OFF control
  • Operating attitude up to 5000 meters(Note.6)
  • Conformal coating
  • 3 years warranty

Specifications

DDR-480B-24Specifications from the official datasheet (2026-09-10 edition)

OUTPUT

DC VOLTAGE
24V
RATED CURRENT
20A
CURRENT RANGE
0 ~ 20A
RATED POWER
480W
PEAK CURRENT 5sec.Note.5
30A
PEAK POWER 5sec.Note.5
12Vo: 601.2W, 24Vo / 48Vo : 720W
RIPPLE & NOISE (max.)Note.2
120mVp-p
VOLTAGE ADJ. RANGE
24 ~ 28V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±1.0%
SETUP, RISE TIME
500ms, 60ms
HOLD UP TIME (Typ.)
Please refer to page 6 hold up time (Load de-rating curve )

INPUT

VOLTAGE RANGE CONTINUOUSNote.4
16.8 ~ 33.6Vdc
VOLTAGE RANGE 100msNote.4
14.4 ~ 16.8Vdc
EFFICIENCY (Typ.)
91%
DC CURRENT (Typ.)
23A @24Vdc
INRUSH CURRENT (Typ.)
30A
INTERRUPTION OF VOLTAGE SUPPLY
EN50155: 2021-B/C/D type comply with S2 level (10ms)@ full load

PROTECTION

OVERLOADNote.5
Normally works within 150% rated output power for more than 5 seconds and then constant current protection 105~135% rated output power with auto-recovery
OVER VOLTAGE
28.8 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
REVERSE POLARITY
By internal, MOSFET, no damage, recovers automatically after fault condition is removed
UNDER VOLTAGE LOCKOUT
24Vin (B - type) :Power ON≥16.8V , OFF≤16.5V

FUNCTION

DC OK REALY CONTACT RATINGS (max.)
30Vdc/1A resistive load
CURRENT SHARING
Up to 1920W (3+1 units). Please refer to the Function Manual
REMOTE ON-OFF CONTROL
Please refer to the Function Manual

ENVIRONMENT

WORKING TEMP.
-40 ~ +80℃ (Refer to "Derating Curve")
WORKING HUMIDITY
5 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85, 5 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 55℃)
VIBRATION
Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373
OPERATING ALTITUDENote.6
5000 meters / OVCⅡ

SAFETY & EMC

SAFETY STANDARDS
UL 62368-1, IEC 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:4KVdc I/P-FG:2.5KVdc O/P-FG:0.71KVdc
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500Vdc / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55032 (CISRP32)Class A
RadiatedBS EN/EN55032 (CISRP32)Class B
Voltage FlickerBS EN/EN61000-3-3-----
Harmonic Current----------
EMC IMMUNITY

BS EN/EN55035

ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, 8KV air; Level 3, 6KV contact; criteria A
RadiatedBS EN/EN61000-4-3Level 3, 10V/m; criteria A
EFT / BurstBS EN/EN61000-4-4Level 3, 2KV; criteria A
SurgeBS EN/EN61000-4-5Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-FG ;criteria A
ConductedBS EN/EN61000-4-6Level 3, 10V; criteria A
Magnetic FieldBS EN/EN61000-4-8Level 4, 30A/m; criteria A
RAILWAY STANDARD
Compliance to BS EN/EN45545-2 for fire protection ; Meet BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC

OTHERS

MTBF
750.3K hrs min. Telcordia SR-332 (Bellcore) ; 101.7K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
85.5*125.2*129.2mm (W*H*D)
PACKING
1.375Kg;8pcs/12Kg/0.95CUFT
Test conditions and notes7
  1. 1. All parameters NOT specially mentioned are measured at normal input (B:24Vdc , C:48Vdc , D:110Vdc ) , rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Derating may be needed under low input voltage. Please check the derating curve for more details.
  5. 5. 150% 5 seconds, please refer to peak loading curves.
  6. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than2000m(6500ft).
  7. 7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

Technical drawings

DDR-480B-24 Block Diagram
Block Diagram
DDR-480B-24 Derating Curve
Derating Curve
DDR-480B-24 Peak Loading
Peak Loading
DDR-480B-24 Function Manual
Function Manual
DDR-480B-24 Input Under-Voltage Protection
Input Under-Voltage Protection
DDR-480B-24 Inrush Current
Inrush Current
DDR-480B-24 Hold-up Time
Hold-up Time
DDR-480B-24 Efficiency vs Load & Vin Curve
Efficiency vs Load & Vin Curve
DDR-480B-24 D D R - 4 8 0 series
D D R - 4 8 0 series
DDR-480B-24 Mechanical Specification
Mechanical Specification
DDR-480B-24 Installation Instruction
Installation Instruction

Typical applications

  • Bus,tram,metro or railway system
  • Industrial control system
  • Semiconductor fabrication equipment
  • Factory automation
  • Electro-mechanical
  • Wireless network
  • Telecom or datacom system

Downloads

FAQ

Can I use the DDR-480B-24 to power 24V industrial automation equipment from a 24V battery bus?

Yes. The DDR-480B-24 accepts 16.8-33.6V DC input and outputs isolated 24V at up to 20A (480W). This makes it ideal for converting an unregulated 24V battery bus into a clean, isolated 24V rail for PLCs, VFDs, HMI panels, and other automation devices that need stable voltage with noise isolation.

Is the DDR-480B-24 suitable for high-current 24V LED lighting systems powered from a 24V DC distribution bus?

Yes. At 480W and 20A, it can drive large arrays of 24V LED panels, strip lighting, or signage. The 4KVdc I/O isolation separates the lighting load from the main bus, and the DIN rail mount fits standard electrical panels. Ensure the total connected LED load does not exceed 480W.

Can the DDR-480B-24 provide isolated 24V power for marine or vehicle electrical systems running on a nominal 24V bus?

Yes. Marine and heavy-vehicle 24V battery systems typically range from about 20V to 30V, which falls within the 16.8-33.6V input window. The 4KVdc input-to-output isolation separates downstream equipment from the vehicle bus. The -40°C to +80°C rating (with load derating at high ambient temperatures) suits engine rooms when the unit is mounted inside a protective enclosure.

Does the DDR-480B-24 require active cooling or ventilation in an enclosed panel?

The datasheet specifies an operating range of -40°C to +80°C, with the allowable load reduced at higher ambient temperatures according to the derating curve. At 480W it generates meaningful heat, so in sealed enclosures verify that the ambient around the unit stays within the derating curve for your load and provide adequate spacing for airflow. Its dimensions are 85.5 x 125.2 x 129.2 mm (W x H x D), so plan enclosure sizing accordingly.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8441778110763, "variants" :[{ "context":"default", "variant_id": 45707213472043, "sku":"DDR-480B-24", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well DDR-480B-24 DC-DC Converter - 480W - 16.8~33.6V in 24V out 20A
Mean Well

Mean Well DDR-480B-24 DC-DC Converter - 480W - 16.8~33.6V in 24V out 20A

DDR-480B-24 is the 24V output model of this series: rated current 20A, rated power 480W, typical efficiency 91%.

DDR-480 series is a 480W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, ultra slim width (85.5mm), 2:1 wide input voltage, fanless design, -40~+80℃ wide operating temperature, 4KVdc I/O isolation, 150% peak load, current sharing, DC OK, adjustable output voltage and full protective functions. This series of models has various input options: 16.8~33.6V / 33.6~67.2V / 67.2~154V and multiple output options: 12V / 24V / 48V and can be used for industrial & railway control, security control, communication system and other fields. Suitable applications include to DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable...etc.

Features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • Width only 85.5mm
  • 2:1 wide input range
  • -40~+80℃ wide operating temperature
  • 150% peak load capability
  • Current sharing up to 1920W(3+1)
  • DC output adjustable
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Protections: Short circuit / Overload / Over voltage / Over temperature / Input reverse polarity/ Input under voltage protection
  • 4KVdc I/O isolation(Reinforced isolation)
  • DC OK relay contact
  • Remote ON-OFF control
  • Operating attitude up to 5000 meters(Note.6)
  • Conformal coating
  • 3 years warranty

Typical applications

  • Bus,tram,metro or railway system
  • Industrial control system
  • Semiconductor fabrication equipment
  • Factory automation
  • Electro-mechanical
  • Wireless network
  • Telecom or datacom system

Model

  • 100W - 24V out - 9~18V in
  • 120W - 24V out - 16.8~33.6V in
  • 120W - 24V out - 33.6~67.2V in
  • 120W - 24V out - 67.2~154V in
  • 15W - 24V out - 9~36V in
  • 15W - 24V out - 18~75V in
  • 240W - 24V out - 16.8~33.6V in
  • 240W - 24V out - 33.6~67.2V in
  • 240W - 24V out - 67.2~154V in
  • 30W - 24V out - 9~36V in
  • 30W - 24V out - 18~75V in
  • 480W - 24V out - 16.8~33.6V in
  • 480W - 24V out - 33.6~67.2V in
  • 480W - 24V out - 67.2~154V in
  • 60W - 24V out - 9~36V in
  • 60W - 24V out - 18~75V in
View product