Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SI06W8-09 is the 9V output model of this series: rated power 6W, typical efficiency 82.5%.
SI06W8 and DI06W8 series are 6W isolated and regulated module type DC-DC converter with DIP 1"x1" package. It features international standard pins, a high efficiency up to 86%, wide working temperature range -40~+90℃, 3KVDC I/P-O/P isolation voltage, compliance to BS EN/EN55032 radiated Class A without additional components, continuous-mode short circuit, overload, Input under voltage protection etc. The models account input voltage 9~75V 8:1 ultra-wide input range, and various output voltage, 3.3V/5V/9V/12V/15V/24V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for all kinds of systems, such as industrial control, telecommunication field, distributed power architecture, and so on.
Features
- DIP 1"x1" package with industry standard pinout
- 8:1 ultra-wide input range
- Operating temperature range -40 ~ +90℃
- No minimum load required
- Comply to BS EN/EN55032 radiated Class A without additional components
- High efficiency up to 86%
- Protections: Short circuit (Continuous) / Overload / Over voltage / Input under voltage
- 3KVDC I/O isolation
- Remote ON/OFF control (optional)
- 3 years warranty
Specifications
INPUT
- VOLTAGE RANGE
- 9 ~ 75Vdc
- INPUT VOLTAGE (RANGE)
- Normal 12V,24V,36V,48V,72V (9 ~ 75V)
- INPUT CURRENT NO LOAD
- 7mA
- INPUT CURRENT FULL LOAD
- 301mA
- SURGE VOLTAGE (100ms max.)
- 100Vdc
- FILTER
- Capacitor network
- PROTECTION
- Fuse recommended. 2A Slow-Blow Type
OUTPUT
- OUTPUT VOLTAGE
- 9V
- OUTPUT CURRENT
- 0~667mA
- VOLTAGE ACCURACY
- ±2%
- RATED POWER
- 6W
- RIPPLE & NOISENote.2
- 100mVp-p
- LINE REGULATIONNote.3
- ±0.2% (±0.5% for 3.3Vo)
- LOAD REGULATIONNote.4
- ±0.5%
- SWITCHING FREQUENCY (Typ.)
- 300KHz (PWM)
- EFFICIENCY (TYP.)
- 82.5%
- CAPACITOR LOAD (MAX.)* For each output
- 680μF
PROTECTION
- SHORT CIRCUIT
- Protection type : Continuous, automatic recovery
- OVERLOAD
- 110 ~ 230% rated output power Protection type : Recovers automatically after fault condition is removed
- OVER VOLTAGE
- Protection type : Clamp by TVS diode
- UNDER VOLTAGE LOCKOUT Start-up voltage
- 8.8V
- UNDER VOLTAGE LOCKOUT Shutdown voltage
- 8.5V
FUNCTION
- REMOTE CONTROL (OPTIONAL)
- Power ON: RC ~ -Vin > 2.5Vdc ~ 6Vdc or open circuit Power OFF: RC ~ -Vin <1Vdc or short
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +90℃ (Refer to "Derating Curve")
- CASE TEMPERATURE
- +105℃ max.
- WORKING HUMIDITY
- 5% ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +125℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.05% / ℃ (0 ~ 71℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 1 ~ 3sec./260℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note.5)
- SAFETY STANDARDS
- EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVDC
- ISOLATION RESISTANCE
- I/P-O/P:1000M Ohms / 500VDC / 25℃/ 70% RH
- ISOLATION CAPACITANCE (Typ.)
- 1000pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032(CISPR32) N/A Radiated BS EN/EN55032(CISPR32) Class A without external components Class B with external components - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 contact ±4KV Radiated Susceptibility BS EN/EN61000-4-3 3V/m EFT/Burest BS EN/EN61000-4-4 ±0.5KV Surge BS EN/EN61000-4-5 Line-Line±0.5KV Conducted BS EN/EN61000-4-6 3Vrms Magnetic field immunity BS EN/EN61000-4-8 1A/m
OTHERS
- MTBF
- >400Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 25.4*25.4*10.2mm (1*1*0.401 inch)
- CASE MATERIAL
- Black coated copper with non-conductive base
- PACKING
- 20g; 10pcs/per tube, 600pcs/60 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input(24Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 0% to 100% rated load.
- 5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Telecom/datacom system
- Wireless network
- Industrial control facility
- Instrument
- Analyzer
- Detector
- Data switch
Downloads
Datasheet1
FAQ
What is the Mean Well SI06W8-03 designed for?
The Mean Well SI06W8-03 is a regulated DC-DC converter for applications that need a stable 3.3V DC output from a very wide DC input range. Its 6W rating and compact 1 inch by 1 inch DIP package make it suited to space-constrained industrial and embedded power designs.
What makes the SI06W8-03 different from standard DC-DC converters?
A key differentiator is its 8:1 ultra-wide input range, which gives it more flexibility than converters built for narrower input windows. This model also combines 3KVDC input-to-output isolation, no minimum load requirement, and protection coverage for overload, over temperature, over voltage, short circuit, and input under voltage.
Is the SI06W8-03 suitable for harsh temperature environments?
Yes. Mean Well specifies an operating temperature range of -40 to +90 degrees C, which supports use in demanding industrial environments. Buyers still need to confirm that the rest of the system is rated for the same conditions, but this converter itself is designed for wide-temperature operation.
Does this converter require a minimum load to regulate properly?
No. The SI06W8-03 is specified with no minimum load required, which can simplify product selection in low-load or variable-load designs. That makes it useful where the output demand may fluctuate or remain very light during parts of operation.
What are the main specifications of the Mean Well SI06W8-03?
This model is a single-output regulated DC-DC converter rated for 6W with a 3.3V output. It includes up to 86% efficiency, 3KVDC input/output isolation, an industry-standard DIP 1 inch by 1 inch package, optional remote ON/OFF control, and a 3-year warranty.
Does the SI06W8-03 include built-in compliance and protection features?
Yes. Mean Well states that it complies with BS EN/EN55032 radiated Class A without additional components, and it includes continuous short-circuit, overload, over-temperature, over-voltage, and input under-voltage protection. Those features help make it a stronger fit for reliability-focused industrial equipment.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other SI06W8 Series Models
5 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well SI06W8-24 8:1 Ultra-Wide Input DC-DC Regulated Converter, Single Output 6W 24V 250mA | 6W | 24V | 0.25A | IP20 | View |
| Mean Well SI06W8-15 8:1 Ultra-Wide Input DC-DC Regulated Converter, Single Output 6W 15V 400mA | 6W | 15V | 0.4A | IP20 | View |
| Mean Well SI06W8-12 8:1 Ultra-Wide Input DC-DC Regulated Converter, Single Output 6W 12V 500mA | 6W | 12V | 0.5A | IP20 | View |
| Mean Well SI06W8-05 8:1 Ultra-Wide Input DC-DC Regulated Converter, Single Output 6W 5V 1.2A | 6W | 5V | 1.2A | IP20 | View |
| Mean Well SI06W8-03 8:1 Ultra-Wide Input DC-DC Regulated Converter, Single Output 6W 3.3V 1.82A | 6W | 3.3V | 1.8182A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.