Overview
SI06W8-12 is the 12V output model of this series: rated power 6W, typical efficiency 85%.
SI06W8 and DI06W8 series are 6W isolated and regulated module type DC-DC converter with DIP 1"x1" package. It features international standard pins, a high efficiency up to 86%, wide working temperature range -40~+90℃, 3KVDC I/P-O/P isolation voltage, compliance to BS EN/EN55032 radiated Class A without additional components, continuous-mode short circuit, overload, Input under voltage protection etc. The models account input voltage 9~75V 8:1 ultra-wide input range, and various output voltage, 3.3V/5V/9V/12V/15V/24V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for all kinds of systems, such as industrial control, telecommunication field, distributed power architecture, and so on.
Features
- DIP 1"x1" package with industry standard pinout
- 8:1 ultra-wide input range
- Operating temperature range -40 ~ +90℃
- No minimum load required
- Comply to BS EN/EN55032 radiated Class A without additional components
- High efficiency up to 86%
- Protections: Short circuit (Continuous) / Overload / Over voltage / Input under voltage
- 3KVDC I/O isolation
- Remote ON/OFF control (optional)
- 3 years warranty
Specifications
INPUT
- VOLTAGE RANGE
- 9 ~ 75Vdc
- INPUT VOLTAGE (RANGE)
- Normal 12V,24V,36V,48V,72V (9 ~ 75V)
- INPUT CURRENT NO LOAD
- 7mA
- INPUT CURRENT FULL LOAD
- 300mA
- SURGE VOLTAGE (100ms max.)
- 100Vdc
- FILTER
- Capacitor network
- PROTECTION
- Fuse recommended. 2A Slow-Blow Type
OUTPUT
- OUTPUT VOLTAGE
- 12V
- OUTPUT CURRENT
- 0~500mA
- VOLTAGE ACCURACY
- ±2%
- RATED POWER
- 6W
- RIPPLE & NOISENote.2
- 100mVp-p
- LINE REGULATIONNote.3
- ±0.2% (±0.5% for 3.3Vo)
- LOAD REGULATIONNote.4
- ±0.5%
- SWITCHING FREQUENCY (Typ.)
- 300KHz (PWM)
- EFFICIENCY (TYP.)
- 85%
- CAPACITOR LOAD (MAX.)* For each output
- 470μF
PROTECTION
- SHORT CIRCUIT
- Protection type : Continuous, automatic recovery
- OVERLOAD
- 110 ~ 230% rated output power Protection type : Recovers automatically after fault condition is removed
- OVER VOLTAGE
- Protection type : Clamp by TVS diode
- UNDER VOLTAGE LOCKOUT Start-up voltage
- 8.8V
- UNDER VOLTAGE LOCKOUT Shutdown voltage
- 8.5V
FUNCTION
- REMOTE CONTROL (OPTIONAL)
- Power ON: RC ~ -Vin > 2.5Vdc ~ 6Vdc or open circuit Power OFF: RC ~ -Vin <1Vdc or short
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +90℃ (Refer to "Derating Curve")
- CASE TEMPERATURE
- +105℃ max.
- WORKING HUMIDITY
- 5% ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +125℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.05% / ℃ (0 ~ 71℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 1 ~ 3sec./260℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note.5)
- SAFETY STANDARDS
- EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVDC
- ISOLATION RESISTANCE
- I/P-O/P:1000M Ohms / 500VDC / 25℃/ 70% RH
- ISOLATION CAPACITANCE (Typ.)
- 1000pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032(CISPR32) N/A Radiated BS EN/EN55032(CISPR32) Class A without external components Class B with external components - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 contact ±4KV Radiated Susceptibility BS EN/EN61000-4-3 3V/m EFT/Burest BS EN/EN61000-4-4 ±0.5KV Surge BS EN/EN61000-4-5 Line-Line±0.5KV Conducted BS EN/EN61000-4-6 3Vrms Magnetic field immunity BS EN/EN61000-4-8 1A/m
OTHERS
- MTBF
- >400Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 25.4*25.4*10.2mm (1*1*0.401 inch)
- CASE MATERIAL
- Black coated copper with non-conductive base
- PACKING
- 20g; 10pcs/per tube, 600pcs/60 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input(24Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 0% to 100% rated load.
- 5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Telecom/datacom system
- Wireless network
- Industrial control facility
- Instrument
- Analyzer
- Detector
- Data switch
Downloads
Datasheet1
FAQ
What is the main use case for the Mean Well SI06W8-03 DC-DC converter?
This model is intended for regulated DC-DC power conversion in compact industrial and embedded equipment. Its 6W power rating, single 3.3V output, and 8:1 ultra-wide input range make it a practical choice where input voltage can vary significantly across systems.
What output does the SI06W8-03 provide?
The SI06W8-03 is a single-output regulated converter rated for 3.3V output and 6W power. It is designed for applications that need a stable low-voltage DC rail from a much wider DC input range.
How does the 8:1 ultra-wide input range benefit this model?
An 8:1 input range gives this converter more flexibility in systems where the source voltage may fluctuate or differ across deployments. That makes the SI06W8-03 easier to standardize across multiple industrial or mobile power environments than a narrower-input converter.
Is the SI06W8-03 suitable for harsh temperature environments?
Yes. This model is specified for operation from -40°C to +90°C, which supports use in demanding industrial environments with wide ambient temperature variation. That range is useful for equipment exposed to cold starts or elevated internal enclosure temperatures.
Does this converter require a minimum load to operate properly?
No. The SI06W8-03 is specified with no minimum load requirement, which can simplify use in systems with variable or intermittent power draw. That can be helpful in control, sensing, or standby applications where the load is not always constant.
What protection and isolation features are included in the SI06W8-03?
This model includes protection for short circuit, overload, over temperature, over voltage, and input under voltage. It also provides 3KVDC input-to-output isolation, which is valuable in designs that need added electrical separation between power domains.
What compliance and reliability features does this model offer?
The SI06W8-03 is stated to comply with BS EN/EN55032 radiated Class A without additional components. It also offers efficiency up to 86% and is backed by a 3-year warranty, supporting use in long-life industrial applications.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other SI06W8 Series Models
5 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well SI06W8-24 8:1 Ultra-Wide Input DC-DC Regulated Converter, Single Output 6W 24V 250mA | 6W | 24V | 0.25A | IP20 | View |
| Mean Well SI06W8-15 8:1 Ultra-Wide Input DC-DC Regulated Converter, Single Output 6W 15V 400mA | 6W | 15V | 0.4A | IP20 | View |
| Mean Well SI06W8-09 8:1 Ultra-Wide Input DC-DC Regulated Converter, Single Output 6W 9V 667mA | 6W | 9V | 0.6667A | IP20 | View |
| Mean Well SI06W8-05 8:1 Ultra-Wide Input DC-DC Regulated Converter, Single Output 6W 5V 1.2A | 6W | 5V | 1.2A | IP20 | View |
| Mean Well SI06W8-03 8:1 Ultra-Wide Input DC-DC Regulated Converter, Single Output 6W 3.3V 1.82A | 6W | 3.3V | 1.8182A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.