Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SKA20W8-03 is the 3.3V output model of this series: rated power 20W, typical efficiency 85%.
SKA20W8 and DKA20W8 series are 20W isolated and regulated module type DC-DC converter with DIP 2"x1" package. It features international standard pins, a high efficiency up to 89%, wide working temperature range -40~+90℃, 3KVdc I/P-O/P isolation voltage, compliance to BS EN/EN55032 radiated Class A without additional components, continuous-mode short circuit, overload, over voltage, input under voltage protection etc. The models account for 9~75Vdc 8:1 ultra-wide input range, and various output voltage, 3.3V/5V/12V/15V/24V for single output and ±12V/±15V for dual outputs, which are suitable for all kinds of systems, such as industrial control, telecommunication field, distributed power architecture, and so on.
Features
- DIP 2"x1" package with industry standard pinout
- 8:1(9~75Vdc) ultra-wide input range
- Operating temperature range -40 ~ +90℃
- No minimum load required
- Comply to BS EN/EN55032 radiated Class A without additional components
- High efficiency up to 89%
- Protections: Short circuit (Continuous) / Overload / Over voltage / UVLO
- 3KVdc I/O isolation
- Remote ON/OFF control
- 3 years warranty
Specifications
INPUT
- VOLTAGE RANGE
- 9~75Vdc
- INPUT VOLTAGE (RANGE)
- Nominal 12V, 24V,36V,48V,72V (9 ~ 75V)
- INPUT CURRENT NO LOAD
- 10mA
- INPUT CURRENT FULL LOAD
- 809mA
- SURGE VOLTAGE (100ms max.)
- 100Vdc
- FILTER
- Pi network
- PROTECTION
- Fuse recommended 6A Slow-Blow
OUTPUT
- OUTPUT VOLTAGE
- 3.3V
- OUTPUT CURRENT
- 0~5000mA
- EFFICIENCY (TYP.)
- 85%
- CAPACITOR LOAD (MAX.)* For each output
- 1000μF
- VOLTAGE ACCURACY
- ±2%
- RATED POWER
- 20W
- RIPPLE & NOISENote.2
- 150mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- ±1% for 3.3Vdc output, ±0.5% for other output
- CROSS REGULATION
- ±5% @ 25% ~ 100% load only dual output
- SWITCHING FREQUENCY (Typ.)
- 200KHz (PWM)
PROTECTION
- SHORT CIRCUIT
- Protection type : Continuous, automatic recovery
- OVERLOAD
- 110 ~ 230% Protection type : Recovers automatically after fault condition is removed
- OVER VOLTAGE
- Clamp by TVS diodes
- UNDER VOLTAGE LOCKOUT (Typ.)
- Start-up voltage: 8.8Vdc Shutdown voltage: 7.5Vdc
FUNCTION
- REMOTE CONTROL (By request)
- Power ON: R.C. ~ -Vin >2.5~30Vdc or open circuit ; Power OFF: R.C. ~ -Vin <1Vdc or short
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +90℃ (Refer to "Derating Curve")
- CASE TEMPERATURE
- +110℃ max.
- WORKING HUMIDITY
- 5% ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +125℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 80℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 3 ~ 5 sec./265℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note.5)
- SAFETY STANDARDS
- EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVdc
- ISOLATION RESISTANCE
- I/P-O/P:1000M Ohms / 500Vdc / 25℃/ 70% RH
- ISOLATION CAPACITANCE (Typ.)
- 1000pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032(CISPR32) N/A Radiated BS EN/EN55032(CISPR32) Class A without additional components Class B with additional components - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, ±8KV air, Level 2, ±4KV contact Radiated Susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EFT/Bursts BS EN/EN61000-4-4 Level 1, 0.5KV Surge BS EN/EN61000-4-5 Level 2, Line-Line±0.5KV Conducted BS EN/EN61000-4-6 Level 2, 3V(e.m.f.) Magnetic Field BS EN/EN61000-4-8 Level 1, 1A/m
OTHERS
- MTBF
- >600Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 50.8*25.4*11.2mm (2*1*0.44 inch)
- CASE MATERIAL
- Six-side shielded case
- PACKING
- 31g ; 10pcs/per tube, 400pcs/40 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input (24Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 0% to 100% rated load.
- 5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies."(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Telecom/datacom system
- Wireless network
- Industrial control facility
- Instrument
- Analyzer
- Detector
- Data switch
Downloads
::specification::
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.