💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well ERDN40-48 Redundancy Module Power Supply 40A

redundancy modulesupport 1+1 and 1+N redundancyrelay contacts for monitoring power status
SKU ERDN40-48
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

ERDN40-48 is the model of this series: rated current 0~40A per input Continuous, typical efficiency 98%.

The E RDN 4 0 series is a 4 0A redundancy module that can be used with a power supply to improve overall system operation reliability. Product key features include: 12V/24 V/48V input voltage for selection, support N+1 and 1+1 redundancy systems,built-in two rails DC input contacts and single output. The MOSFET technology implemented can reduce heat loss and reduce the voltage difference between the input and output voltages, built-in 2 channels DC OK relay contacts for monitoring output status, ultra-wide operating temperature of -40 to +80°C.

Features

  • Support 1+1 and N+1 redundancy system
  • 2 channels input and 1 output
  • Suitable for redundancy operation of 12V/24V/48V system
  • Output current up to 40A
  • Cooling by free air convection
  • -40~+80°C ultra-wide operating temperature ( >+60°C derating)
  • Built-in 2 channels DC OK signal and alarm relay contact
  • 3 years warranty

Specifications

ERDN40-48Specifications from the official datasheet (2026-03-06 edition)

INPUT

NUMBER OF INPUT
2 Channels
DC NORMAL VOLTAGE
48Vdc
DC VOLTAGE RANGE
36~60Vdc
RATED CURRENT
0~40A per input Continuous
VOLTAGE DROP (Vin-Vout) (max.)
0.2V
PEAK CURRENT
0~60A per input 5Sec.
EFFICIENCY (Typ.)
98%
INPUT REVERSE CURRENT (max.)
1mA
INPUT REVERSE VOLTAGE (max.)
65Vdc

OUTPUT

RATED CURRENT
0~40A, Continuous
PEAK CURRENT (max.)
60A, 5Sec.
CAPACITANCE(Typ.)
320uF
STANDBY POWER LOSSES(Typ.)
1.5W

PROTECTION

OVERLOAD
<60A, 5Sec. No damage
SHORT CIRCUIT
<60A, 5Sec. No damage

FUNCTION

REDUNDANCY
For 1+1 redundancy ,and support N+1 redundancy
BOTH INPUTS VOLTAGE ALARM
<34.2V or >63V (±5%)
RELAY
30Vdc/1A resistive load
LED STATUS DISPLAY
Green LED OK

ENVIRONMENT

COOLING
Free air convection
WORKING TEMP.Note.2
-40 ~ +80℃ (Refer to "Derating Curve")
WORKING HUMIDITY
5 ~ 95% RH non-condensing
STORAGE TEMP.
-40 ~ +85℃
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 60℃)
VIBRATION
Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373
OPERATING ALTITUDENote.3
5000 meters/OVC II

SAFETY & EMC

SAFETY STANDARDS
IEC62368-1, UL62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE
IP/OP - Chassis : 0.5KVac ; IP/OP- Relay : 0.5KVac ; Relay - Chassis : 0.5KVac
ISOLATION RESISTANCE
IP/OP - Chassis, IP/OP- Relay, Relay - Chassis:>100M Ohms / 500Vdc / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55032(CISPR32)Class B
RadiatedBS EN/EN55032(CISPR32)Class B
EMC IMMUNITY

BS EN/EN55035, BS EN/EN61000-6-2(BS EN/EN50082-2)

ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 4, 15KV air; Level 3, 8KV contact; criteria A
RadiatedBS EN/EN61000-4-3Level 3, 10V/m; criteria A
EFT / BurstBS EN/EN61000-4-4Level 3, 2KV; criteria A
SurgeBS EN/EN61000-4-5Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-Chassis ;criteria A
ConductedBS EN/EN61000-4-6Level 3, 10V; criteria A
Magnetic FieldBS EN/EN61000-4-8Level 4, 30A/m; criteria A

OTHERS

MTBF
1687.9K hrs min. Telcordia SR-332 (Bellcore) ; 294.1K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
97*99*36mm (W*D*H)
PACKING
0.276Kg;45psc/14Kg/0.94CUFT
Test conditions and notes4
  1. 1. All parameters NOT specially mentioned are measured at normal input , rated load and 25℃ of ambient temperature.
  2. 2. Derating may be needed over high ambient temperature. Please check the derating curve for more details.
  3. 3. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  4. 4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

Technical drawings

ERDN40-48 Derating Curve
Derating Curve
ERDN40-48 Typical Application Notes
Typical Application Notes
ERDN40-48 Mechanical Specification
Mechanical Specification

Typical applications

  • Industrial control system
  • Semiconductor fabrication equipment
  • Factory automation
  • Electro-mechanical apparatus

Downloads

FAQ

Can I use the ERDN40-48 for a redundant 48V industrial automation power system?

Yes. The ERDN40-48 is a redundancy module for 48V systems (36~60Vdc input) rated for 40A continuous, and it supports both 1+1 and N+1 redundancy. That makes it suitable for 48V industrial and automation systems that require redundancy.

Is the ERDN40-48 a good choice for 48V communications equipment that needs uptime protection?

It can be a fit for 48V communications or network equipment where redundant power architecture is required. The module is rated for 40A continuous and includes DC OK relay contacts for monitoring power status.

Can this model be used in a 48V control panel with 1+1 or 1+N redundant supplies?

Yes. Supporting 1+1 and N+1 redundancy is one of its core features, and it is intended for redundant 48V power distribution. Its 48V system voltage and 40A rating define the load class it supports.

Is the ERDN40-48 suitable for higher-power 48V embedded or industrial systems?

Yes, for 48V systems that need redundant power handling. It carries up to 40A continuous (60A peak for 5 seconds), the same current rating as the other models in the series, and is aimed at 48V loads within that rating.

What are the differences between the ERDN40-48 and the other ERDN40 redundancy modules?

All models are 40A redundancy modules that share the same redundancy concept; they differ in system voltage. The ERDN40-48 is for 48V systems (36~60Vdc input), the ERDN40-12 for 12V systems (9~14Vdc), and the ERDN40-24 for 24V systems (19~29Vdc).

Can the ERDN40-48 operate in demanding temperature environments or outdoor enclosures?

Its specified operating temperature range is -40°C to +80°C, with derating above +60°C. However, no IP rating is listed, so the provided specs do not establish outdoor protection against dust or water.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Other ERDN40 Models

2 other models
{ "id":8442019119403, "variants" :[{ "context":"default", "variant_id": 45708966428971, "sku":"ERDN40-48", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well ERDN40-48 Redundancy Module Power Supply 40A
Mean Well

Mean Well ERDN40-48 Redundancy Module Power Supply 40A

ERDN40-48 is the model of this series: rated current 0~40A per input Continuous, typical efficiency 98%.

The E RDN 4 0 series is a 4 0A redundancy module that can be used with a power supply to improve overall system operation reliability. Product key features include: 12V/24 V/48V input voltage for selection, support N+1 and 1+1 redundancy systems,built-in two rails DC input contacts and single output. The MOSFET technology implemented can reduce heat loss and reduce the voltage difference between the input and output voltages, built-in 2 channels DC OK relay contacts for monitoring output status, ultra-wide operating temperature of -40 to +80°C.

Features

  • Support 1+1 and N+1 redundancy system
  • 2 channels input and 1 output
  • Suitable for redundancy operation of 12V/24V/48V system
  • Output current up to 40A
  • Cooling by free air convection
  • -40~+80°C ultra-wide operating temperature ( >+60°C derating)
  • Built-in 2 channels DC OK signal and alarm relay contact
  • 3 years warranty

Typical applications

  • Industrial control system
  • Semiconductor fabrication equipment
  • Factory automation
  • Electro-mechanical apparatus
View product