Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well HEP-100-12 Power Supply 100.08W 12V 8.34A
Overview
HEP-100-12 is the 12V output model of this series: rated current 8.34A, rated power 100.08W, typical efficiency 92%.
HEP-100 is a 100W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 93%, enabling HEP-100 perfectly work between -55℃ and +70℃ under free air convection.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 93%
- Fanless design, cooling by free air convection
- -55~+70℃ wide operating range
- Aluminum case and filling with heat-conducted silicone
- IP65 design, optional IP68 rated model available
- Meet 6KV surge immunity level
- Withstand 10G vibration test
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Operating altitude up to 5000 meters (Note.9)
- 6 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 8.34A
- RATED POWER
- 100.08W
- RIPPLE & NOISE (max.)Note.2
- 120mVp-p
- VOLTAGE ADJ. RANGENote.5
- 10.8 ~ 13.5V
- CURRENT ADJ. RANGE
- Can be adjusted by internal potentiometer for A type only
- CURRENT ADJ. RANGE
- 5 ~ 8.34A
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±2.0%
- SETUP, RISE TIMENote.7
- 1200ms,50ms/115VAC 500ms,50ms/230VAC at full load
- HOLD UP TIME (Typ.)
- 16ms at full load 230VAC /115VAC
INPUT
- VOLTAGE RANGENote.4
- 90~264VAC (277VAC operational) 128~370VDC(390VDC operational)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC, PF>0.91/277VAC at full load
- EFFICIENCY (Typ.)
- 92%
- AC CURRENT (Typ.)
- 1.2A / 115VAC 0.55A / 230VAC 0.5A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 60A at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVERLOAD
- 105 ~ 125% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 14 ~ 17V Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -55 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -60 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 60℃)
- VIBRATION
- 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.6,9
- UL62368-1, IEC62368-1,IP65 (or IP68 for HEP-100 Blank type), EAC TP TC 004 approved ; Design refer to BS EN/EN62368-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level (surge 6KV), EAC TP TC 020
OTHERS
- MTBF
- 1970.2K hrs min. Telcordia SR-332 (Bellcore) ; 164.8Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 220*68*38.8mm (L*W*H)
- PACKING
- 1.12Kg; 12pcs/14.4Kg/0.8CUFT
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 5. A type only.
- 6. Safety and EMC design refer to BS EN/EN60598-1, CNS15233, GB7000.1, FCC part18.
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Outdoor telecommunication equipment
- Outdoor electronic signage and billboard
- Petroleum plant or mine shaft facility
Downloads
Certificates6
Test reports1
Catalogues1
FAQ
Can I use the Mean Well HEP-100-12 for a 12V industrial control or automation system?
Yes, this model is a 12V constant voltage power supply rated for 100.08W and 8.34A output. That makes it suitable for 12V industrial control, automation, and embedded systems that need a regulated 12V DC supply within that power and current range.
Is the HEP-100-12 suitable for 12V embedded or IT equipment in harsh environments?
It can be a fit for 12V embedded and IT equipment when the load stays within 100.08W and 8.34A. The 92% typical efficiency, 10G vibration resistance, and operating range of -55°C to +70°C (with derating per the derating curve) make it appropriate for demanding environments.
Can this power supply run a 12V outdoor electronics or monitoring system?
It is designed for harsh-environment use and carries an IP68 rating, so it is suited to outdoor or exposed locations where a sealed power supply is needed. It provides 12V constant voltage output up to 8.34A and 100.08W, so the connected 12V system needs to stay within those limits.
Can the HEP-100-12 be used indoors and outdoors in very hot or very cold conditions?
Yes, the unit is rated IP68 and has an operating temperature range of -55°C to +70°C, with output derating at the temperature extremes per the derating curve. Those specs make it suitable for both indoor and outdoor environments where moisture, dust, or wide temperature swings are a concern.
How does the HEP-100-12 compare with other HEP-100 series voltage options?
The HEP-100-12 is rated 100.08W at 12V and 8.34A, and the HEP-100-12A has the same 100.08W, 12V, and 8.34A ratings. Other HEP-100 variants are HEP-100-15 and HEP-100-15A at 100.05W, 15V, 6.67A; HEP-100-24 and HEP-100-24A at 96W, 24V, 4A; and HEP-100-36 and HEP-100-36A at 95.4W, 36V, 2.65A. The remaining options are HEP-100-48 and HEP-100-48A at 96W, 48V, 2A, plus HEP-100-54 and HEP-100-54A at 95.58W, 54V, 1.77A.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.