💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well HEP-100-36A Power Supply 95.4W 36V 2.65A

fanless designhigh efficiency up to 96%rugged metal case with IP65 design(IP68 option available)withstand 10G vibrationsuitable for harsh environment
SKU HEP-100-36A
Log in to see price Trade pricing & online ordering for account holders
Model

Select model — 14 in this family

HEP-100-36A
Available to order
|

Overview

HEP-100-36A is the 36V output model of this series: rated current 2.65A, rated power 95.4W, typical efficiency 93%.

HEP-100 is a 100W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 93%, enabling HEP-100 perfectly work between -55℃ and +70℃ under free air convection.

Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 93%
  • Fanless design, cooling by free air convection
  • -55~+70℃ wide operating range
  • Aluminum case and filling with heat-conducted silicone
  • IP65 design, optional IP68 rated model available
  • Meet 6KV surge immunity level
  • Withstand 10G vibration test
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Operating altitude up to 5000 meters (Note.9)
  • 6 years warranty

Specifications

HEP-100-36ASpecifications from the official datasheet (2025-10-10 edition)

OUTPUT

DC VOLTAGE
36V
RATED CURRENT
2.65A
RATED POWER
95.4W
RIPPLE & NOISE (max.)Note.2
200mVp-p
VOLTAGE ADJ. RANGENote.5
33 ~ 40V
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer for A type only
CURRENT ADJ. RANGE
1.65 ~ 2.65A
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
SETUP, RISE TIMENote.7
1200ms,50ms/115VAC 500ms,50ms/230VAC at full load
HOLD UP TIME (Typ.)
16ms at full load 230VAC /115VAC

INPUT

VOLTAGE RANGENote.4
90~264VAC (277VAC operational) 128~370VDC(390VDC operational)
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.91/277VAC at full load
EFFICIENCY (Typ.)
93%
AC CURRENT (Typ.)
1.2A / 115VAC 0.55A / 230VAC 0.5A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 60A at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC

PROTECTION

OVERLOAD
105 ~ 125% Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
41 ~ 46V Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

ENVIRONMENT

WORKING TEMP.
-55 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-60 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 60℃)
VIBRATION
20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDSNote.6,9
UL62368-1, IEC62368-1,IP65 (or IP68 for HEP-100 Blank type), EAC TP TC 004 approved ; Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level (surge 6KV), EAC TP TC 020

OTHERS

MTBF
1970.2K hrs min. Telcordia SR-332 (Bellcore) ; 164.8Khrs min. MIL-HDBK-217F (25℃)
DIMENSION
220*68*38.8mm (L*W*H)
PACKING
1.12Kg; 12pcs/14.4Kg/0.8CUFT
Test conditions and notes10
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
  5. 5. A type only.
  6. 6. Safety and EMC design refer to BS EN/EN60598-1, CNS15233, GB7000.1, FCC part18.
  7. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
  8. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  9. 9. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
  10. 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

HEP-100-36A Block Diagram
Block Diagram
HEP-100-36A Mechanical Specification
Mechanical Specification

Typical applications

  • Outdoor telecommunication equipment
  • Outdoor electronic signage and billboard
  • Petroleum plant or mine shaft facility

Downloads

FAQ

Can the HEP-100-36A power a 36V embedded controller or industrial computer?

Yes, if the equipment is designed for 36V DC input and draws no more than 2.65A or 95.4W. This is a constant-voltage model, so it is intended for loads that expect a regulated 36V supply.

Is this a good fit for 36V motors or motion devices in automation equipment?

It may fit lower-power 36V DC motion hardware only if the total steady load remains within 95.4W and 2.65A. Buyers should match the device's required 36V input and confirm the current demand does not exceed the supply's output rating.

Can I use the HEP-100-36A for 36V communication or monitoring equipment in a plant?

Yes, if that equipment requires 36V constant voltage and stays under 95.4W. The 10G vibration tolerance and operating range of -55°C to +70°C (with derating per the derating curve) make it suitable for industrial environments.

Is the HEP-100-36A suitable for outdoor installations?

The HEP-100-36A is rated IP65 water-resistant, so it is better suited to indoor use or protected outdoor locations than the IP68 version. Its 10G vibration rating and -55°C to +70°C temperature range still make it appropriate for demanding environments.

What is the difference between the HEP-100-36A and other HEP-100 models?

The HEP-100 line includes 12V at 100.08W and 8.34A, 15V at 100.05W and 6.67A, 24V at 96W and 4A, 36V at 95.4W and 2.65A, 48V at 96W and 2A, and 54V at 95.58W and 1.77A. The HEP-100-36A matches the HEP-100-36 electrically at 95.4W, 36V, and 2.65A.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8343855563051, "variants" :[{ "context":"default", "variant_id": 45320749678891, "sku":"HEP-100-36A", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HEP-100-36A Power Supply 95.4W 36V
Mean Well

Mean Well HEP-100-36A Power Supply 95.4W 36V 2.65A

HEP-100-36A is the 36V output model of this series: rated current 2.65A, rated power 95.4W, typical efficiency 93%.

HEP-100 is a 100W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 93%, enabling HEP-100 perfectly work between -55℃ and +70℃ under free air convection.

Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 93%
  • Fanless design, cooling by free air convection
  • -55~+70℃ wide operating range
  • Aluminum case and filling with heat-conducted silicone
  • IP65 design, optional IP68 rated model available
  • Meet 6KV surge immunity level
  • Withstand 10G vibration test
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Operating altitude up to 5000 meters (Note.9)
  • 6 years warranty

Typical applications

  • Outdoor telecommunication equipment
  • Outdoor electronic signage and billboard
  • Petroleum plant or mine shaft facility

Model

  • 100W 36V
  • 100W 36V Adjustable
  • 150W 36V
  • 150W 36V Adjustable
  • 185W 36V
  • 185W 36V Adjustable
  • 240W 36V
  • 240W 36V Adjustable
  • 320W 36V
  • 320W 36V Adjustable
  • 480W 36V
  • 480W 36V Adjustable
  • 600W 36V
  • 600W 36V Adjustable
View product