Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well HEP-100-48A Power Supply 96W 48V 2A
Overview
HEP-100-48A is the 48V output model of this series: rated current 2A, rated power 96W, typical efficiency 93%.
HEP-100 is a 100W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 93%, enabling HEP-100 perfectly work between -55℃ and +70℃ under free air convection.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 93%
- Fanless design, cooling by free air convection
- -55~+70℃ wide operating range
- Aluminum case and filling with heat-conducted silicone
- IP65 design, optional IP68 rated model available
- Meet 6KV surge immunity level
- Withstand 10G vibration test
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Operating altitude up to 5000 meters (Note.9)
- 6 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 2A
- RATED POWER
- 96W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGENote.5
- 43 ~ 53V
- CURRENT ADJ. RANGE
- Can be adjusted by internal potentiometer for A type only
- CURRENT ADJ. RANGE
- 1.25 ~ 2A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.7
- 1200ms,50ms/115VAC 500ms,50ms/230VAC at full load
- HOLD UP TIME (Typ.)
- 16ms at full load 230VAC /115VAC
INPUT
- VOLTAGE RANGENote.4
- 90~264VAC (277VAC operational) 128~370VDC(390VDC operational)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC, PF>0.91/277VAC at full load
- EFFICIENCY (Typ.)
- 93%
- AC CURRENT (Typ.)
- 1.2A / 115VAC 0.55A / 230VAC 0.5A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 60A at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVERLOAD
- 105 ~ 125% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 54 ~ 63V Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -55 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -60 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 60℃)
- VIBRATION
- 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.6,9
- UL62368-1, IEC62368-1,IP65 (or IP68 for HEP-100 Blank type), EAC TP TC 004 approved ; Design refer to BS EN/EN62368-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level (surge 6KV), EAC TP TC 020
OTHERS
- MTBF
- 1970.2K hrs min. Telcordia SR-332 (Bellcore) ; 164.8Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 220*68*38.8mm (L*W*H)
- PACKING
- 1.12Kg; 12pcs/14.4Kg/0.8CUFT
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 5. A type only.
- 6. Safety and EMC design refer to BS EN/EN60598-1, CNS15233, GB7000.1, FCC part18.
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Outdoor telecommunication equipment
- Outdoor electronic signage and billboard
- Petroleum plant or mine shaft facility
Downloads
Certificates6
Test reports1
Catalogues1
FAQ
Can the HEP-100-48A power a 48V building automation or control panel load?
Yes, if the load requires 48V DC and does not exceed 96W or 2A. Because it is a constant-voltage unit, it is best matched to automation equipment designed for fixed 48V input.
Is this a fit for 48V industrial radios, gateways, or monitoring devices?
It can be a fit when the connected 48V equipment stays within the 2A maximum output current and 96W total output. The wide 90-264VAC input range (277VAC operational) also helps when the supply is used across different AC systems.
Can I use the HEP-100-48A for 48V LED strips or low-power signage systems?
Yes, provided the lighting load is a 48V constant-voltage load and remains within 96W. Its compact 220.0 × 68.0 × 38.8 mm housing can be useful where space is limited.
Is the HEP-100-48A okay for outdoor use?
The HEP-100-48A is rated IP65 water-resistant, so it is generally better for indoor use or protected outdoor areas rather than more exposed conditions. It still supports operation from -55°C to +70°C (with derating per the derating curve) and is rated for 10G vibration.
How does the HEP-100-48A compare to other HEP-100 outputs?
The HEP-100 series offers 12V at 100.08W and 8.34A, 15V at 100.05W and 6.67A, 24V at 96W and 4A, 36V at 95.4W and 2.65A, 48V at 96W and 2A, and 54V at 95.58W and 1.77A. The HEP-100-48A has the same 96W, 48V, 2A output as the HEP-100-48.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.


