Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well HEP-150-54A Power Supply 151.2W 54V 2.8A
Overview
HEP-150-54A is the 54V output model of this series: rated current 2.8A, rated power 151.2W, typical efficiency 94%.
HEP-150 is a 150W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 94%, enabling HEP-150 perfectly work between -55℃ and +70℃ under free air convection.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 94%
- Fanless design, cooling by free air convection
- -55~+70℃ wide operating range
- Aluminum case and filling with heat-conducted silicone
- IP65 design, optional IP68 rated model available
- Meet 6KV surge immunity level
- Withstand 10G vibration test
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Operating altitude up to 5000 meters (Note.9)
- 6 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 54V
- RATED CURRENT
- 2.8A
- RATED POWER
- 151.2W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGENote.5
- 49 ~ 58V
- CURRENT ADJ. RANGE
- 1.68 ~ 2.8A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.7
- 1000ms,50ms/115VAC 500ms,50ms/230VAC at full load
- HOLD UP TIME (Typ.)
- 16ms at full load 230VAC /115VAC
INPUT
- VOLTAGE RANGENote.4
- 90~264VAC (277VAC operational) 128~370VDC(390VDC operational)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
- EFFICIENCY (Typ.)
- 94%
- AC CURRENT (Typ.)
- 1.7A / 115VAC 0.75A / 230VAC 0.7A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 65A at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVERLOAD
- 105 ~ 125% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 59 ~ 65V
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -55 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -60 ~ +80℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 60℃)
- VIBRATION
- 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.6,9
- UL62368-1, IEC62368-1,IP65 (or IP68 for HEP-150 Blank type), EAC TP TC 004 approved ; Design refer to BS EN/EN62368-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level (surge 6KV), EAC TP TC 020
OTHERS
- MTBF
- 1967.4K hrs min. Telcordia SR-332 (Bellcore) ; 164.2Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 228*68*38.8mm (L*W*H)
- PACKING
- 1.15Kg; 12pcs/14.8Kg/0.8CUFT
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 5. A type only.
- 6. Safety and EMC design refer to BS EN/EN60598-1, CNS15233, GB7000.1, FCC part18.
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Outdoor telecommunication equipment
- Outdoor electronic signage and billboard
- Petroleum plant or mine shaft facility
Downloads
Certificates6
Test reports1
Catalogues1
FAQ
Can I use the HEP-150-54A for a 54V industrial control or automation load?
Yes, this model is a constant-voltage 54V power supply rated for 151.2W and 2.8A. It is suited to equipment that specifically requires a 54V DC source within that power and current range.
Is the HEP-150-54A a good fit for embedded or edge equipment in harsh industrial environments?
It is specified for 10G vibration (20-500Hz along the X, Y and Z axes) and carries an IP65 rating. The operating range of -55°C to +70°C (refer to the derating curve) also makes it suitable for embedded or control equipment exposed to very low or very high ambient temperatures.
Can this power supply be used for outdoor 54V equipment cabinets or enclosures?
It can be used in outdoor applications where IP65 water resistance is appropriate. IP65 supports resistance to water ingress and dust, and the unit is built for -55°C to +70°C operation.
Would the HEP-150-54A work for a 54V automation device that runs continuously?
It provides a stable 54V constant-voltage output (±1.0% voltage tolerance) up to 151.2W and 2.8A. Its typical efficiency of 94% keeps heat losses low, which helps in enclosed industrial equipment.
How does the HEP-150-54A compare with other 54V models in the HEP series?
On the HEP-150 sheet, the only other 54V model is the HEP-150-54, which has the same 151.2W at 2.8A rating. The HEP-150-54A is IP65, while the HEP-150-54 (blank type) is IP68. The other HEP-150 voltages are 12V, 15V, 24V, 36V and 48V.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.