HEP-185-36A is the 36V output model of this series: rated current 5.2A, rated power 187.2W, typical efficiency 93.5%.
HEP-185 is a 185W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 94%, enabling HEP-185 perfectly work between -55℃ and +70℃ under free air convection.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 94%
- Fanless design, cooling by free air convection
- -55~+70℃ wide operating range
- Aluminum case and filling with heat-conducted silicone
- IP65 design, optional IP68 rated model available
- Meet 6KV surge immunity level
- Withstand 10G vibration test
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Operating altitude up to 5000 meters (Note.9)
- 6 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 36V
- RATED CURRENT
- 5.2A
- RATED POWER
- 187.2W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGENote.5
- 33 ~ 40V
- CURRENT ADJ. RANGE
- 2.6 ~ 5.2A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.7
- 1000ms,50ms/115VAC 500ms,50ms/230VAC at full load
- HOLD UP TIME (Typ.)
- 16ms at full load 230VAC /115VAC
INPUT
- VOLTAGE RANGENote.4
- 90~264VAC (277VAC operational) 128~370VDC(390VDC operational)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
- EFFICIENCY (Typ.)
- 93.5%
- AC CURRENT (Typ.) 12V
- 1.8A / 115VAC 0.8A / 230VAC 0.7A / 277VAC
- AC CURRENT (Typ.) 15V ~ 54V
- 2.1A / 115VAC 1A / 230VAC 0.8A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 65A at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVERLOAD
- 105 ~ 125% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 41 ~ 46V
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -55 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -60 ~ +80℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 60℃)
- VIBRATION
- 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.6,9
- UL62368-1, IEC62368-1, IP65 (or IP68 for HEP-185 Blank type), EAC TP TC 004 approved ; Design refer to BS EN/EN62368-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level (surge 6KV), EAC TP TC 020
OTHERS
- MTBF
- 1967.4K hrs min. Telcordia SR-332(Bellcore) ; 164.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 228*68*38.8mm (L*W*H)
- PACKING
- 1.15Kg; 12pcs/14.8Kg/0.8CUFT
Certifications & ratings
- IP level
- IP65 IP68 (Optional)
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 5. A type only.
- 6. Safety and EMC design refer to BS EN/EN60598-1, CNS15233, GB7000.1, FCC part18.
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Outdoor telecommunication equipment
- Outdoor electronic signage and billboard
- Petroleum plant or mine shaft facility
Downloads
Certificates5
Test reports1
Catalogues1
FAQ
Can the HEP-185-36A be used in a 36V industrial control or automation system?
Yes, it is a 36V constant-voltage power supply rated for 187.2W and 5.2A. That fits many 36VDC automation, control, and embedded loads that are designed around a fixed 36V bus. Its 90-264VAC input (277VAC operational) also supports use across a wide range of AC mains conditions.
Is the HEP-185-36A suitable for 36V process equipment or enclosed machine electronics?
It can be a fit when the equipment requires 36V constant voltage and stays within 5.2A and 187.2W. The IP65 rating helps where the unit is exposed to dust or water. Its 10G vibration rating also suits harsh industrial environments.
Can I use the HEP-185-36A for a 36V lighting or display load that needs more than 150W?
Yes, if the system is a 36V constant-voltage load and the total demand does not exceed 187.2W or 5.2A. That rating sits above the 150W level the load requires. That extra margin can matter on larger 36V loads.
Is the HEP-185-36A meant for indoor use only, or can it handle harsher environments?
This version carries an IP65 water-resistant rating, so it is intended for dusty or wet industrial locations rather than dry indoor spaces only. It is specified for -55°C to +70°C operation, subject to the derating curve. If the application calls for the more sealed variant, the sibling HEP-185-36 is the IP68 version.
What distinguishes the HEP-185-36A from the other HEP-185 models?
The HEP-185 range includes 156W at 12V and 13A, 172W at 15V and 11.5A, 187.2W at 24V and 7.8A, 187.2W at 36V and 5.2A, 187.2W at 48V and 3.9A, and 186.3W at 54V and 3.45A. The HEP-185-36A matches the HEP-185-36 electrically at 187.2W, 36V, and 5.2A. The key selection factors are the required output voltage and the enclosure style, with this model using IP65 water-resistant construction.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.