Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRP-100-24 is the 24V output model of this series: rated current 4.5A, rated power 108W, typical efficiency 88.5%.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 90%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage
- Protections: Over temperature (optional)
- Cooling by free air convection
- 1U low profile 38mm
- Built-in remote ON-OFF control
- No load power consumption<0.5W
- All using 105℃ long life electrolytic capacitors
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 4.5A
- CURRENT RANGE
- 0 ~ 4.5A
- RATED POWER
- 108W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 22.8 ~ 28.8V
- VOLTAGE TOLERANCENote.3
- ±1.5%
- LINE REGULATION
- ±0.2%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 2500ms, 100ms/230VAC 2500ms, 100ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 20ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 88.5%
- AC CURRENT (Typ.)
- 1.1A/115VAC 0.6A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 65A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting for Vo=50 ~ 100% of rated voltage, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 30 ~ 34.8V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- REMOTE CONTROL
- RC+/RC- : 0 ~ 0.8V= power on ; 4 ~ 10V = power off
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +60℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.04%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/ EN61000-4-2,3,4,5,6,8,11, BS EN/ EN55035, BS EN/ EN61000-6-2, heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 2344.3K hrs min. Telcordia SR-332 (Bellcore) ; 295.8K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 159*97*38mm (L*W*H)
- PACKING
- 0.56Kg; 24pcs/15Kg/0.9CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the HRP-100-24 for a 24V PLC, I/O, or automation control system?
Yes, if the system uses constant 24V DC and the total demand stays within 108W and 4.5A. That makes it suitable for lower-power 24V automation loads rather than larger 24V cabinets with heavier current demand.
Is the HRP-100-24 suitable for 24V sensors, relays, and industrial control accessories?
It can support 24V sensors, relays, and control accessories when their combined load does not exceed 4.5A or 108W. Because it is a constant-voltage model, it matches equipment designed for a fixed 24V DC supply.
Can this model power 24V embedded or industrial computing equipment?
It is a reasonable choice for 24V embedded or industrial computing hardware that requires constant 24V output and stays within 108W total load. The 85-264VAC input range is also useful where the same hardware platform may see different AC input conditions.
Will the HRP-100-24 handle cold or hot factory environments?
Its specified operating range is -40°C to +60°C, which supports use in demanding industrial temperature conditions. No IP rating is listed in the supplied specs, so these data do not confirm suitability for direct outdoor exposure.
How does the HRP-100-24 compare with the other HRP-100 versions?
The listed HRP-100 outputs are 3.3V 20A 66W, 5V 17A 85W, 7.5V 13.5A 101.3W, 12V 8.5A 102W, 15V 7A 105W, 24V 4.5A 108W, 36V 2.9A 104.4W, and 48V 2.2A 105.6W. This 24V version has the highest wattage shown in that group at 108W, with current scaled to 4.5A at 24V.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.