Overview
HRP-100-3.3 is the 3.3V output model of this series: rated current 20A, rated power 66W, typical efficiency 78%.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 90%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage
- Protections: Over temperature (optional)
- Cooling by free air convection
- 1U low profile 38mm
- Built-in remote ON-OFF control
- No load power consumption<0.5W
- All using 105℃ long life electrolytic capacitors
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 3.3V
- RATED CURRENT
- 20A
- CURRENT RANGE
- 0 ~ 20A
- RATED POWER
- 66W
- RIPPLE & NOISE (max.)Note.2
- 80mVp-p
- VOLTAGE ADJ. RANGE
- 3.1 ~ 3.8V
- VOLTAGE TOLERANCENote.3
- +2.5,-3.5%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±2.0%
- SETUP, RISE TIME
- 2500ms, 100ms/230VAC 2500ms, 100ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 20ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 78%
- AC CURRENT (Typ.)
- 1.1A/115VAC 0.6A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 65A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting for Vo=50 ~ 100% of rated voltage, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- REMOTE CONTROL
- RC+/RC- : 0 ~ 0.8V= power on ; 4 ~ 10V = power off
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +60℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.04%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/ EN61000-4-2,3,4,5,6,8,11, BS EN/ EN55035, BS EN/ EN61000-6-2, heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 2344.3K hrs min. Telcordia SR-332 (Bellcore) ; 295.8K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 159*97*38mm (L*W*H)
- PACKING
- 0.56Kg; 24pcs/15Kg/0.9CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the HRP-100-3.3 for 3.3V embedded processors, FPGA boards, or logic-heavy controllers?
Yes, if the equipment needs a constant 3.3V rail and the total draw stays within 20A and 66W. That makes it better aligned with high-current 3.3V electronics than higher-voltage models in the same family.
Is the HRP-100-3.3 suitable for industrial control electronics that run on a 3.3V backplane?
It can be used where the control electronics are designed for constant 3.3V DC and the combined load does not exceed 66W or 20A. Buyers should match it to 3.3V-only sections of the design, not to equipment that expects 5V, 12V, 24V, 36V, or 48V.
Can this model power multiple 3.3V embedded modules from one supply?
It can, as long as the total current remains within 20A and the total power remains within 66W. The constant-voltage 3.3V output is intended for equipment that already regulates around a fixed 3.3V DC input.
Is the HRP-100-3.3 intended for outdoor use or protected indoor equipment?
The temperature rating is -40°C to +60°C, so the operating range supports harsh indoor equipment environments. No IP rating is listed in the provided specs, so outdoor or washdown suitability is not established here.
When should I choose the HRP-100-3.3 instead of a larger 3.3V HRP model?
Choose it when your 3.3V load fits within 20A and 66W. If you need more 3.3V capacity, a larger model is required; check that model's own datasheet, as this sheet covers only the HRP-100 series.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.