Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRP-100-7.5 is the 7.5V output model of this series: rated current 13.5A, rated power 101.3W, typical efficiency 84%.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 90%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage
- Protections: Over temperature (optional)
- Cooling by free air convection
- 1U low profile 38mm
- Built-in remote ON-OFF control
- No load power consumption<0.5W
- All using 105℃ long life electrolytic capacitors
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 7.5V
- RATED CURRENT
- 13.5A
- CURRENT RANGE
- 0 ~ 13.5A
- RATED POWER
- 101.3W
- RIPPLE & NOISE (max.)Note.2
- 100mVp-p
- VOLTAGE ADJ. RANGE
- 7.1 ~ 9V
- VOLTAGE TOLERANCENote.3
- ±2.5%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.5%
- SETUP, RISE TIME
- 2500ms, 100ms/230VAC 2500ms, 100ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 20ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 84%
- AC CURRENT (Typ.)
- 1.1A/115VAC 0.6A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 65A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting for Vo=50 ~ 100% of rated voltage, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 9.4 ~ 10.9V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- REMOTE CONTROL
- RC+/RC- : 0 ~ 0.8V= power on ; 4 ~ 10V = power off
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +60℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.04%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/ EN61000-4-2,3,4,5,6,8,11, BS EN/ EN55035, BS EN/ EN61000-6-2, heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 2344.3K hrs min. Telcordia SR-332 (Bellcore) ; 295.8K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 159*97*38mm (L*W*H)
- PACKING
- 0.56Kg; 24pcs/15Kg/0.9CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the HRP-100-7.5 for equipment that specifically needs 7.5V DC?
Yes, if the load is designed for constant 7.5V input and remains within 13.5A and 101.3W. It should only be used where the equipment's required voltage matches 7.5V DC.
Is the HRP-100-7.5 suitable for embedded or industrial electronics with a 7.5V power rail?
It is appropriate for 7.5V electronics that need a regulated constant-voltage source up to 13.5A. That makes it useful for embedded assemblies, controller subsystems, or specialty industrial electronics built around 7.5V input.
Can this power supply support a moderate-power 7.5V automation device from AC mains?
Yes. The unit takes 85-264VAC input and delivers 7.5V DC output, with up to 13.5A available and 101.3W total rated power.
Would the HRP-100-7.5 fit a 7.5V production fixture or test station?
It can be a good fit where the fixture needs a stable 7.5V source and the total draw stays within 101.3W. Its constant-voltage output is intended for loads that are specified around a fixed 7.5V DC supply.
What are the output choices in the HRP-100 series if I am comparing voltage versions?
The listed HRP-100 models are 3.3V at 20A and 66W, 5V at 17A and 85W, 7.5V at 13.5A and 101.3W, 12V at 8.5A and 102W, 15V at 7A and 105W, 24V at 4.5A and 108W, 36V at 2.9A and 104.4W, and 48V at 2.2A and 105.6W. The HRP-100-7.5 is the 7.5V option in that lineup.
Can the HRP-100-7.5 be used in cold or warm industrial locations?
The specified operating temperature range is -40°C to +60°C, so it is intended for wide indoor ambient conditions. No IP rating is given in the provided specs, so dust-tight or weather-exposed use should not be assumed.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.