Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRP-150-12 is the 12V output model of this series: rated current 13A, rated power 156W, typical efficiency 88%.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- 1U low profile 38mm
- Built-in remote sense function
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 13A
- CURRENT RANGE
- 0 ~ 13A
- RATED POWER
- 156W
- RIPPLE & NOISE (max.)Note.2
- 120mVp-p
- VOLTAGE ADJ. RANGE
- 10.2 ~ 13.8V
- VOLTAGE TOLERANCENote.3
- ±1.5%
- LINE REGULATION
- ±0.3%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 88%
- AC CURRENT (Typ.)
- 1.7A/115VAC 0.9A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 70A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 14.4 ~ 16.8V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -50 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.04%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035 , BS EN/ EN61000-6-2 ,heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 1742.7K hrs min. Telcordia SR-332 (Bellcore) ; 238.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 159*97*38mm (L*W*H)
- PACKING
- 0.61Kg; 24pcs/15.6Kg/0.9CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: HRP-150-3.3/-5/-7.5/-12/-15)
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the HRP-150-12 for a 12V industrial automation panel or controller?
Yes, if the equipment requires constant 12V DC and the load stays within 13A and 156W. It is suited to higher-power 12V control applications compared with lower-output 12V models.
Is the HRP-150-12 suitable for 12V embedded systems with multiple connected loads?
It can be, because it provides 12V constant-voltage output at up to 13A with 156W total power. That gives more headroom for embedded or control assemblies with several 12V loads sharing one supply.
Can this model power a 12V HMI, relay, or control subsystem from standard AC input?
Yes. It accepts 85-264VAC input and delivers 12V DC output, so it fits 12V automation subsystems that need operation from a wide AC mains range.
Would the HRP-150-12 fit a 12V bench, fixture, or industrial test application?
It is appropriate where the fixture or test setup needs a regulated 12V supply and the total demand does not exceed 13A or 156W. The constant-voltage design is intended for equipment built around a fixed 12V DC input.
How does the HRP-150-12 compare with other HRP-150 output versions?
The listed HRP-150 models are 3.3V at 30A and 99W, 5V at 26A and 130W, 7.5V at 20A and 150W, 12V at 13A and 156W, 15V at 10A and 150W, 24V at 6.5A and 156W, 36V at 4.3A and 154.8W, and 48V at 3.3A and 158.4W. The HRP-150-12 is the 12V, 13A version in that range.
Is the HRP-150-12 suitable for hot or cold indoor industrial environments?
Its operating temperature range is -40°C to +70°C, with output derating at higher ambient temperatures as shown in the derating curve. No IP rating is included in the provided specs, so outdoor exposure or washdown use cannot be confirmed from this information alone.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HRP-150 Models
1 other model| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HRP-150-36 Power Supply 154.8W 36V 4.3A | 154.8W | 36V | 4.3A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.