Mean Well HRP-150-3.3 Power Supply 99W 3.3V 30A

built-in active PFChigh efficiency up to 90%no load power consumption <0.5W~0.75W
SKU HRP-150-3.3
Log in to see price Trade pricing & online ordering for account holders
Model

Select model — 7 in this family

HRP-150-3.3
Available to order
|

Overview

HRP-150-3.3 is the 3.3V output model of this series: rated current 30A, rated power 99W, typical efficiency 78.5%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • 1U low profile 38mm
  • Built-in remote sense function
  • 5 years warranty

Specifications

HRP-150-3.3Specifications from the official datasheet (2026-07-13 edition)

OUTPUT

DC VOLTAGE
3.3V
RATED CURRENT
30A
CURRENT RANGE
0 ~ 30A
RATED POWER
99W
RIPPLE & NOISE (max.)Note.2
80mVp-p
VOLTAGE ADJ. RANGE
2.8 ~ 3.8V
VOLTAGE TOLERANCENote.3
±2.5%
LINE REGULATION
±0.5%
LOAD REGULATION
±1.0%
SETUP, RISE TIME
3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load

INPUT

VOLTAGE RANGENote.5
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.99/115VAC at full load
EFFICIENCY (Typ.)
78.5%
AC CURRENT (Typ.)
1.7A/115VAC 0.9A/230VAC
INRUSH CURRENT (Typ.)
35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC

PROTECTION

OVERLOAD
105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-50 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.04%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC (Note 4)

SAFETY STANDARDS
UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035 , BS EN/ EN61000-6-2 ,heavy industry level, EAC TP TC 020

OTHERS

MTBF
1742.7K hrs min. Telcordia SR-332 (Bellcore) ; 238.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
159*97*38mm (L*W*H)
PACKING
0.61Kg; 24pcs/15.6Kg/0.9CUFT
Test conditions and notes7
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. 6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: HRP-150-3.3/-5/-7.5/-12/-15)
  7. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

HRP-150-3.3 Mechanical Specification
Mechanical Specification
HRP-150-3.3 Block Diagram
Block Diagram
HRP-150-3.3 Derating Curve
Derating Curve

Downloads

FAQ

Can I use the HRP-150-3.3 for 3.3V industrial logic or controller electronics?

Yes, this is a constant voltage 3.3V power supply rated for 99W and up to 30A. It is suited to industrial or embedded electronics that run from a 3.3V DC rail and need higher current capacity.

Is the HRP-150-3.3 suitable for powering 3.3V embedded development or test systems?

It can be used for 3.3V embedded benches, fixtures, or validation systems where a regulated high-current source is required. The supply delivers up to 30A at 3.3V from an 85-264VAC input range.

Can this model support multiple 3.3V boards from one supply?

It can, provided the total load stays within 99W and 30A. That makes it practical for grouped 3.3V digital loads such as processor boards, logic assemblies, or control backplanes.

Is HRP-150-3.3 a fit for high-current 3.3V automation electronics?

Yes, the 3.3V output and 30A rating make it more suitable for high-current low-voltage electronics than higher-voltage HRP-150 models. It is a constant-voltage supply whose output can be trimmed within 2.8-3.8V.

Can the HRP-150-3.3 be used outside or in unprotected areas?

Its operating temperature range is -40C to +70C, with output derating at higher temperatures per the derating curve. However, no IP rating is listed, so it should be used in a protected enclosure or other indoor environment where dust and water exposure are controlled.

How does HRP-150-3.3 compare with the other HRP-150 outputs?

In the HRP-150 family, the available outputs are 3.3V at 99W and 30A, 5V at 130W and 26A, 7.5V at 150W and 20A, 12V at 156W and 13A, 15V at 150W and 10A, 24V at 156W and 6.5A, 36V at 154.8W and 4.3A, and 48V at 158.4W and 3.3A. The 3.3V version is the lowest-voltage, highest-current option in that set.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Other HRP-150 Models

1 other model
ModelPowerVoltageCurrent
Mean Well HRP-150-36 Power Supply 154.8W 36V 4.3A 154.8W 36V 4.3A View
{ "id":8343874601259, "variants" :[{ "context":"default", "variant_id": 45320911716651, "sku":"HRP-150-3.3", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HRP-150-3.3  Power Supply 99W 3.3V 30A
Mean Well

Mean Well HRP-150-3.3 Power Supply 99W 3.3V 30A

HRP-150-3.3 is the 3.3V output model of this series: rated current 30A, rated power 99W, typical efficiency 78.5%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • 1U low profile 38mm
  • Built-in remote sense function
  • 5 years warranty

Model

  • 75W 3.3V
  • 100W 3.3V
  • 150W 3.3V
  • 200W 3.3V
  • 300W 3.3V
  • 450W 3.3V
  • 600W 3.3V
View product