Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRP-150-36 is the 36V output model of this series: rated current 4.3A, rated power 154.8W, typical efficiency 89%.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- 1U low profile 38mm
- Built-in remote sense function
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 36V
- RATED CURRENT
- 4.3A
- CURRENT RANGE
- 0 ~ 4.3A
- RATED POWER
- 154.8W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGE
- 28.8 ~ 39.6V
- VOLTAGE TOLERANCENote.3
- ±1.5%
- LINE REGULATION
- ±0.2%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 89%
- AC CURRENT (Typ.)
- 1.7A/115VAC 0.9A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 70A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 41.4 ~ 48.6V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -50 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.04%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035 , BS EN/ EN61000-6-2 ,heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 1742.7K hrs min. Telcordia SR-332 (Bellcore) ; 238.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 159*97*38mm (L*W*H)
- PACKING
- 0.61Kg; 24pcs/15.6Kg/0.9CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: HRP-150-3.3/-5/-7.5/-12/-15)
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the HRP-150-36 for a 36V industrial control or motion system?
Yes, this model provides a constant 36V DC output rated for 154.8W and 4.3A. It fits 36V industrial or automation equipment that operates within those output limits.
Is the HRP-150-36 suitable for 36V embedded or test equipment?
It can be used where a regulated 36V constant voltage source is needed for embedded or production test equipment. The supply delivers up to 4.3A at 36V from an 85-264VAC input.
Can this 36V supply run several 36V devices from one power source?
It can support multiple 36V loads if their combined draw stays at or below 154.8W and 4.3A. That makes it suitable for centralized 36V distribution in industrial electronics assemblies.
Is HRP-150-36 appropriate for 36V automation cabinets with limited space?
Yes, the unit measures 159.0 x 97.0 x 38.0 mm and weighs 0.61 kg, which suits compact panel layouts. Its output is intended for constant voltage 36V applications rather than lower-voltage control rails.
Can the HRP-150-36 handle demanding ambient temperatures?
The specified operating range is -40C to +70C, with output derating at higher temperatures per the derating curve. No IP rating is provided, so it is better suited to protected indoor enclosures than directly exposed outdoor environments.
What other HRP-150 voltage versions are available besides 36V?
The HRP-150 family includes 3.3V at 99W and 30A, 5V at 130W and 26A, 7.5V at 150W and 20A, 12V at 156W and 13A, 15V at 150W and 10A, 24V at 156W and 6.5A, 36V at 154.8W and 4.3A, and 48V at 158.4W and 3.3A. The 36V version sits near the upper end of the series voltage range.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.