💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well HRP-150-36 Power Supply 154.8W 36V 4.3A

built-in active PFChigh efficiency up to 90%no load power consumption <0.5W~0.75W
SKU HRP-150-36
Log in to see price Trade pricing & online ordering for account holders
Model

Select model — 7 in this family

HRP-150-36
In stock
|

Overview

HRP-150-36 is the 36V output model of this series: rated current 4.3A, rated power 154.8W, typical efficiency 89%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • 1U low profile 38mm
  • Built-in remote sense function
  • 5 years warranty

Specifications

HRP-150-36Specifications from the official datasheet (2026-07-13 edition)

OUTPUT

DC VOLTAGE
36V
RATED CURRENT
4.3A
CURRENT RANGE
0 ~ 4.3A
RATED POWER
154.8W
RIPPLE & NOISE (max.)Note.2
200mVp-p
VOLTAGE ADJ. RANGE
28.8 ~ 39.6V
VOLTAGE TOLERANCENote.3
±1.5%
LINE REGULATION
±0.2%
LOAD REGULATION
±0.5%
SETUP, RISE TIME
3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load

INPUT

VOLTAGE RANGENote.5
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.99/115VAC at full load
EFFICIENCY (Typ.)
89%
AC CURRENT (Typ.)
1.7A/115VAC 0.9A/230VAC
INRUSH CURRENT (Typ.)
35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC

PROTECTION

OVERLOAD
105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
41.4 ~ 48.6V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-50 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.04%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC (Note 4)

SAFETY STANDARDS
UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035 , BS EN/ EN61000-6-2 ,heavy industry level, EAC TP TC 020

OTHERS

MTBF
1742.7K hrs min. Telcordia SR-332 (Bellcore) ; 238.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
159*97*38mm (L*W*H)
PACKING
0.61Kg; 24pcs/15.6Kg/0.9CUFT
Test conditions and notes7
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. 6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: HRP-150-3.3/-5/-7.5/-12/-15)
  7. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

HRP-150-36 Mechanical Specification
Mechanical Specification
HRP-150-36 Block Diagram
Block Diagram
HRP-150-36 Derating Curve
Derating Curve

Downloads

FAQ

Can I use the HRP-150-36 for a 36V industrial control or motion system?

Yes, this model provides a constant 36V DC output rated for 154.8W and 4.3A. It fits 36V industrial or automation equipment that operates within those output limits.

Is the HRP-150-36 suitable for 36V embedded or test equipment?

It can be used where a regulated 36V constant voltage source is needed for embedded or production test equipment. The supply delivers up to 4.3A at 36V from an 85-264VAC input.

Can this 36V supply run several 36V devices from one power source?

It can support multiple 36V loads if their combined draw stays at or below 154.8W and 4.3A. That makes it suitable for centralized 36V distribution in industrial electronics assemblies.

Is HRP-150-36 appropriate for 36V automation cabinets with limited space?

Yes, the unit measures 159.0 x 97.0 x 38.0 mm and weighs 0.61 kg, which suits compact panel layouts. Its output is intended for constant voltage 36V applications rather than lower-voltage control rails.

Can the HRP-150-36 handle demanding ambient temperatures?

The specified operating range is -40C to +70C, with output derating at higher temperatures per the derating curve. No IP rating is provided, so it is better suited to protected indoor enclosures than directly exposed outdoor environments.

What other HRP-150 voltage versions are available besides 36V?

The HRP-150 family includes 3.3V at 99W and 30A, 5V at 130W and 26A, 7.5V at 150W and 20A, 12V at 156W and 13A, 15V at 150W and 10A, 24V at 156W and 6.5A, 36V at 154.8W and 4.3A, and 48V at 158.4W and 3.3A. The 36V version sits near the upper end of the series voltage range.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8343874928939, "variants" :[{ "context":"default", "variant_id": 45320913486123, "sku":"HRP-150-36", "inventory_qty" : 1, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HRP-150-36  Power Supply 154.8W 36V 4.3A
Mean Well

Mean Well HRP-150-36 Power Supply 154.8W 36V 4.3A

HRP-150-36 is the 36V output model of this series: rated current 4.3A, rated power 154.8W, typical efficiency 89%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • 1U low profile 38mm
  • Built-in remote sense function
  • 5 years warranty

Model

  • 75W 36V
  • 100W 36V
  • 150W 36V
  • 200W 36V
  • 300W 36V
  • 450W 36V
  • 600W 36V
View product