💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well HRP-150-48 Power Supply 158.4W 48V 3.3A

built-in active PFChigh efficiency up to 90%no load power consumption <0.5W~0.75W
SKU HRP-150-48
Log in to see price Trade pricing & online ordering for account holders
Model

Select model — 7 in this family

HRP-150-48
Available to order
|

Overview

HRP-150-48 is the 48V output model of this series: rated current 3.3A, rated power 158.4W, typical efficiency 89%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • 1U low profile 38mm
  • Built-in remote sense function
  • 5 years warranty

Specifications

HRP-150-48Specifications from the official datasheet (2026-07-13 edition)

OUTPUT

DC VOLTAGE
48V
RATED CURRENT
3.3A
CURRENT RANGE
0 ~ 3.3A
RATED POWER
158.4W
RIPPLE & NOISE (max.)Note.2
240mVp-p
VOLTAGE ADJ. RANGE
40.8 ~ 55.2V
VOLTAGE TOLERANCENote.3
±1.5%
LINE REGULATION
±0.2%
LOAD REGULATION
±0.5%
SETUP, RISE TIME
3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load

INPUT

VOLTAGE RANGENote.5
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.99/115VAC at full load
EFFICIENCY (Typ.)
89%
AC CURRENT (Typ.)
1.7A/115VAC 0.9A/230VAC
INRUSH CURRENT (Typ.)
35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC

PROTECTION

OVERLOAD
105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-50 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.04%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC (Note 4)

SAFETY STANDARDS
UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035 , BS EN/ EN61000-6-2 ,heavy industry level, EAC TP TC 020

OTHERS

MTBF
1742.7K hrs min. Telcordia SR-332 (Bellcore) ; 238.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
159*97*38mm (L*W*H)
PACKING
0.61Kg; 24pcs/15.6Kg/0.9CUFT
Test conditions and notes7
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. 6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: HRP-150-3.3/-5/-7.5/-12/-15)
  7. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

HRP-150-48 Mechanical Specification
Mechanical Specification
HRP-150-48 Block Diagram
Block Diagram
HRP-150-48 Derating Curve
Derating Curve

Downloads

FAQ

Can I use the HRP-150-48 for 48V industrial control or communications equipment?

Yes, this is a constant voltage 48V power supply rated for 158.4W and 3.3A. It is suited to 48V industrial, control, or communications equipment that operates within that output range.

Is the HRP-150-48 suitable for 48V automation or network devices in a control cabinet?

It can be used for 48V DC equipment in enclosed industrial systems where the total load does not exceed 3.3A or 158.4W. The universal 85-264VAC input also helps when the AC source varies by region or facility.

Can this model power a 48V embedded or telecom-style DC bus?

It is appropriate for regulated 48V DC applications that need up to 3.3A. That makes it a practical option for embedded or communications hardware designed around a 48V constant voltage input.

Is HRP-150-48 a good choice when higher voltage and lower current are needed?

Yes, within the HRP-150 range this version provides the highest listed output voltage at 48V with a 3.3A rating. It is intended for loads that need 48V constant voltage rather than higher-current low-voltage rails.

Can the HRP-150-48 be installed in outdoor environments?

The operating temperature range is -40C to +70C, with output derating at higher temperatures per the derating curve. However, no IP rating is listed, so it is better suited to protected indoor enclosures or sealed systems rather than direct outdoor exposure.

How does HRP-150-48 compare to the other HRP-150 outputs?

The HRP-150 family offers 3.3V at 99W and 30A, 5V at 130W and 26A, 7.5V at 150W and 20A, 12V at 156W and 13A, 15V at 150W and 10A, 24V at 156W and 6.5A, 36V at 154.8W and 4.3A, and 48V at 158.4W and 3.3A. The 48V model has the highest output voltage and the lowest current rating in that group.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Other HRP-150 Models

1 other model
ModelPowerVoltageCurrent
Mean Well HRP-150-36 Power Supply 154.8W 36V 4.3A 154.8W 36V 4.3A View
{ "id":8343875256619, "variants" :[{ "context":"default", "variant_id": 45320914370859, "sku":"HRP-150-48", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HRP-150-48  Power Supply 158.4W 48V 3.3A
Mean Well

Mean Well HRP-150-48 Power Supply 158.4W 48V 3.3A

HRP-150-48 is the 48V output model of this series: rated current 3.3A, rated power 158.4W, typical efficiency 89%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • 1U low profile 38mm
  • Built-in remote sense function
  • 5 years warranty

Model

  • 75W 48V
  • 100W 48V
  • 150W 48V
  • 200W 48V
  • 300W 48V
  • 450W 48V
  • 600W 48V
View product