💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well HRP-200-15 Power Supply 201W 15V 13.4A

built-in active PFChigh efficiency up to 90%no load power consumption <0.5W~0.75W
SKU HRP-200-15
Log in to see price Trade pricing & online ordering for account holders
Model

Select model — 7 in this family

HRP-200-15
Available to order
|

Overview

HRP-200-15 is the 15V output model of this series: rated current 13.4A, rated power 201W, typical efficiency 88%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • 1U low profile 38mm
  • Built-in remote sense function
  • 5 years warranty

Specifications

HRP-200-15Specifications from the official datasheet (2026-04-03 edition)

OUTPUT

DC VOLTAGE
15V
RATED CURRENT
13.4A
CURRENT RANGE
0 ~ 13.4A
RATED POWER
201W
RIPPLE & NOISE (max.)Note.2
150mVp-p
VOLTAGE ADJ. RANGE
13.5 ~ 18V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.3%
LOAD REGULATION
±0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load

INPUT

VOLTAGE RANGENote.5
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.99/115VAC at full load
EFFICIENCY (Typ.)
88%
AC CURRENT (Typ.)
2.1A/115VAC 1.1A/230VAC
INRUSH CURRENT (Typ.)
35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1.2mA / 240VAC

PROTECTION

OVERLOAD
105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
18.8 ~ 21.8V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC (Note 4)

SAFETY STANDARDS
UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035,heavy industry level, EAC TP TC 020

OTHERS

MTBF
1830.6K hrs min. Telcordia SR-332 (Bellcore) ; 209.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
199*98*38mm (L*W*H)
PACKING
0.77Kg; 18pcs/14.9Kg/0.87CUFT
Test conditions and notes6
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

HRP-200-15 Mechanical Specification
Mechanical Specification
HRP-200-15 Block Diagram
Block Diagram
HRP-200-15 Derating Curve
Derating Curve

Downloads

FAQ

Can I use the HRP-200-15 for 15V industrial instrumentation?

Yes, if the instrumentation requires a constant 15V source and the total load stays within 201W and 13.4A. That makes it relevant for industrial electronics built around a 15V DC rail rather than the more common 12V or 24V rails. The 85-264VAC input also supports broad AC input conditions.

Is the HRP-200-15 a good fit for test benches or embedded lab equipment that runs on 15V?

It can be a fit for embedded test rigs or bench equipment designed for 15V DC input up to 13.4A. Because it is a constant-voltage unit, the load should be specified for 15V operation. The typical efficiency of 88% can help control heat in enclosed equipment.

Can this power supply support 15V automation or analog control electronics?

Yes, for 15V automation, analog, or measurement electronics that need a fixed 15V output and draw no more than 201W total. Its rated output current is 13.4A, and the output can be adjusted within 13.5-18V if needed. Buyers should still size it against the real steady-state and peak load of the equipment.

What are the other HRP-200 voltage options besides the HRP-200-15?

The HRP-200 family includes 3.3V 132W 40A, 5V 175W 35A, 7.5V 200.3W 26.7A, 12V 200.4W 16.7A, 24V 201.6W 8.4A, 36V 205.2W 5.7A, and 48V 206.4W 4.3A, along with this 15V 201W 13.4A model. Those versions differ mainly by output voltage and current. The right choice depends on the DC rail your equipment is designed to use.

Is the HRP-200-15 suitable for outdoor cabinets or harsh environments?

The operating temperature range is -40°C to +70°C, so the electrical design supports a wide thermal range. However, the provided specs do not list an IP rating, so exposed outdoor use should not be assumed from temperature range alone. For harsher environments, the surrounding enclosure protection still matters.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Other HRP-200 Models

1 other model
ModelPowerVoltageCurrent
Mean Well HRP-200-48 Power Supply 206.4W 48V 4.3A 206.4W 48V 4.3A View
{ "id":8343877157163, "variants" :[{ "context":"default", "variant_id": 45320927510827, "sku":"HRP-200-15", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HRP-200-15  Power Supply 201W 15V 13.4A
Mean Well

Mean Well HRP-200-15 Power Supply 201W 15V 13.4A

HRP-200-15 is the 15V output model of this series: rated current 13.4A, rated power 201W, typical efficiency 88%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • 1U low profile 38mm
  • Built-in remote sense function
  • 5 years warranty

Model

  • 75W 15V
  • 100W 15V
  • 150W 15V
  • 200W 15V
  • 300W 15V
  • 450W 15V
  • 600W 15V
View product