Overview
HRP-200-24 is the 24V output model of this series: rated current 8.4A, rated power 201.6W, typical efficiency 88%.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- 1U low profile 38mm
- Built-in remote sense function
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 8.4A
- CURRENT RANGE
- 0 ~ 8.4A
- RATED POWER
- 201.6W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 21.6 ~ 28.8V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.2%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 88%
- AC CURRENT (Typ.)
- 2.1A/115VAC 1.1A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 70A/230VAC
- LEAKAGE CURRENT
- <1.2mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 30 ~ 34.8V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035,heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 1830.6K hrs min. Telcordia SR-332 (Bellcore) ; 209.5K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 199*98*38mm (L*W*H)
- PACKING
- 0.77Kg; 18pcs/14.9Kg/0.87CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the HRP-200-24 for PLCs, HMIs, and other 24V factory controls?
Yes, this model is well aligned with 24V industrial control loads that need a constant 24V DC source. It is rated for 201.6W and 8.4A, so the connected PLC, HMI, sensor, or control load needs to stay within that output. The 85-264VAC input range also works well across varied plant power conditions.
Is the HRP-200-24 suitable for 24V sensors, relays, and automation accessories?
It can be, as long as the combined 24V load stays within 8.4A and 201.6W. That makes it a practical choice for moderate-power 24V automation assemblies rather than very small point loads or much larger 24V systems. Because it is constant voltage, it should be matched only to equipment that expects a 24V DC supply.
Can this model power a 24V industrial PC or communications device?
Yes, if the device is designed for 24V DC input and does not exceed 201.6W total. That can make it relevant for industrial PCs, gateways, and communications hardware built around a 24V bus. Its typical efficiency of 88% can also help where thermal buildup matters inside cabinets.
How does the HRP-200-24 compare with the other HRP-200 models?
The HRP-200 range includes 3.3V 132W 40A, 5V 175W 35A, 7.5V 200.3W 26.7A, 12V 200.4W 16.7A, 15V 201W 13.4A, 24V 201.6W 8.4A, 36V 205.2W 5.7A, and 48V 206.4W 4.3A. This version is the 24V option and sits in the middle of the range in both voltage and current. It is the relevant choice when the downstream equipment is built for 24V DC.
Can the HRP-200-24 be used in unheated or high-temperature equipment areas?
The specified operating range is -40°C to +70°C, so it is suited to a wide range of equipment temperatures. The provided data does not include an IP rating, so it does not by itself define whether the unit is suitable for exposed indoor dust or outdoor moisture. Environmental protection has to be judged at the system enclosure level.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HRP-200 Models
1 other model| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HRP-200-48 Power Supply 206.4W 48V 4.3A | 206.4W | 48V | 4.3A | View |