Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRP-200-36 is the 36V output model of this series: rated current 5.7A, rated power 205.2W, typical efficiency 89%.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- 1U low profile 38mm
- Built-in remote sense function
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 36V
- RATED CURRENT
- 5.7A
- CURRENT RANGE
- 0 ~ 5.7A
- RATED POWER
- 205.2W
- RIPPLE & NOISE (max.)Note.2
- 250mVp-p
- VOLTAGE ADJ. RANGE
- 28.8 ~ 39.6V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.2%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 89%
- AC CURRENT (Typ.)
- 2.1A/115VAC 1.1A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 70A/230VAC
- LEAKAGE CURRENT
- <1.2mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 41.4 ~ 48.6V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035,heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 1830.6K hrs min. Telcordia SR-332 (Bellcore) ; 209.5K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 199*98*38mm (L*W*H)
- PACKING
- 0.77Kg; 18pcs/14.9Kg/0.87CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the HRP-200-36 for a 36V industrial control panel?
Yes, this model is a constant voltage 36V power supply rated for 5.7A and 205.2W. It fits 36V industrial control or automation loads that need 36V DC and stay within that current and power limit.
Is the HRP-200-36 suitable for 36V embedded or test-bench equipment?
It can be used for embedded or lab equipment that requires a steady 36V constant voltage input. The available output is 5.7A with total power up to 205.2W, so the connected 36V load needs to stay within those ratings.
Can this 36V power supply run 36V automation devices such as actuators, controllers, or DC loads?
It is intended for 36V DC applications where the load expects constant voltage rather than constant current. For automation hardware, the key match is 36V output with up to 5.7A and 205.2W available from the supply.
How does the HRP-200-36 compare with other HRP-200 models?
Within the HRP-200 family, the listed outputs are 3.3V at 40A and 132W, 5V at 35A and 175W, 7.5V at 26.7A and 200.3W, 12V at 16.7A and 200.4W, 15V at 13.4A and 201W, 24V at 8.4A and 201.6W, 36V at 5.7A and 205.2W, and 48V at 4.3A and 206.4W. The HRP-200-36 keeps the same 199.0 × 98.0 × 38.0 mm form factor as the other 200 series units shown here, but its output is specifically 36V constant voltage.
Can the HRP-200-36 be used in hot, cold, or exposed environments?
The operating temperature range is -40°C to +70°C, so the temperature spec supports a wide indoor industrial range. These specs do not list an IP rating, so outdoor or washdown suitability cannot be confirmed from this product data alone.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HRP-200 Models
1 other model| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HRP-200-48 Power Supply 206.4W 48V 4.3A | 206.4W | 48V | 4.3A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.