Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRP-300N-12 is the 12V output model of this series: rated current 27A, rated power 324W, typical efficiency 88%.
HRP-300N is a 300W single output type AC/DC power supply. This series operates for 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan ON-OFF control, working for the temperature up to 70℃.Moreover, HRP-300N provides 250% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- 250% peak power capability
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- 1U low profile 41mm
- Built-in cooling fan ON-OFF control
- Built-in DC OK signal
- Built-in remote sense function
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 27A
- CURRENT RANGE
- 0 ~ 27A
- RATED POWER
- 324W
- RIPPLE & NOISE (max.)Note.2
- 120mVp-p
- VOLTAGE ADJ. RANGE
- 10.2 ~ 13.8V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.3%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 88%
- AC CURRENT (Typ.)
- 3.5A/115VAC 1.8A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 75A/230VAC
- LEAKAGE CURRENT
- <1.5mA / 240VAC
PROTECTION
- OVERLOAD
- Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power on to recover Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power on to recover
- OVER VOLTAGE
- 14.4 ~ 16.8V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- DC OK SIGNAL
- PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V
- FAN CONTROL (Typ.)
- Load 35±15% or RTH2≧50℃ Fan on
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70 ℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85 ℃ , 10 ~ 95% RH
- TEMP. COEFFICIENT
- ± 0.03% /℃ (0 ~ 50 ℃ )
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 , AS/NZS 62368.1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 ℃ / 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class B Radiated BS EN/EN55032 Class B Harmonic current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact RF field BS EN/EN61000-4-3 Level 3, 10V/m EFT/ Burst BS EN/EN61000-4-4 Level 3, 2KV Surge BS EN/EN61000-4-5 Level 4, 4KV/Line-FG; 2KV/Line-Line Conducted BS EN/EN61000-4-6 Level 3, 10V Magnetic Field BS EN/EN61000-4-8 Level 4, 30A/m Voltage Dips and Interruptions BS EN/EN61000-4-11 95% dip 0.5 periods, 30% dip 25 periods, 95% interruptions 250 periods
OTHERS
- MTBF
- 1529.4K hrs min. Telcordia SR-332 (Bellcore) ; 201.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 199*105*41mm (L*W*H)
- PACKING
- 0.9Kg;15pcs/14.5Kg/0.84CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Diagnostic or biological facilities
- Test or measurement systems
- Telecommunication equipment
Downloads
Certificates7
Test reports1
FAQ
Can I use the HRP-300N-12 for 12V industrial automation panels or control cabinets?
Yes, if the system requires a constant 12V supply. This model is rated 324W at 12V with up to 27A, which is appropriate for higher-current 12V control and automation loads within that rating.
Is the HRP-300N-12 suitable for powering 12V embedded systems, IPC accessories, or DC monitoring equipment?
It is suitable for 12V DC loads that need a regulated constant voltage source and stay within 324W and 27A. That profile fits many embedded and industrial electronic assemblies built around a 12V bus.
Can this model support distributed 12V sensors, relays, and low-voltage devices in one system?
It can support multiple 12V loads when the combined demand remains within 27A and 324W. For multi-device systems, the important match is a shared 12V constant voltage requirement across the connected equipment.
Does the HRP-300N-12 work in harsh indoor temperature conditions?
The specified operating temperature range is -40°C to +70°C, with output derating at higher ambient temperatures per the derating curve. No IP rating is listed in the provided specifications, so exposure resistance for outdoor conditions is not defined here.
How does the HRP-300N-12 compare with the other HRP-300N voltage models?
Within the HRP-300N family, the listed models are 12V at 324W and 27A, 24V at 336W and 14A, 36V at 324W and 9A, and 48V at 336W and 7A. The family keeps the same 300W-class platform while changing the output voltage and corresponding output current.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HRP-300N Models
3 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HRP-300N-48 High Peak-Power Power Supply 300W 48V 7A | 336W | 48V | 7A | View |
| Mean Well HRP-300N-36 High Peak-Power Power Supply 300W 36V 9A | 324W | 36V | 9A | View |
| Mean Well HRP-300N-24 High Peak-Power Power Supply 300W 24V 14A | 336W | 24V | 14A | View |