Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRP-300N-24 is the 24V output model of this series: rated current 14A, rated power 336W, typical efficiency 87%.
HRP-300N is a 300W single output type AC/DC power supply. This series operates for 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan ON-OFF control, working for the temperature up to 70℃.Moreover, HRP-300N provides 250% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- 250% peak power capability
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- 1U low profile 41mm
- Built-in cooling fan ON-OFF control
- Built-in DC OK signal
- Built-in remote sense function
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 14A
- CURRENT RANGE
- 0 ~ 14A
- RATED POWER
- 336W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 21.6 ~ 28.8V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.2%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 87%
- AC CURRENT (Typ.)
- 3.5A/115VAC 1.8A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 75A/230VAC
- LEAKAGE CURRENT
- <1.5mA / 240VAC
PROTECTION
- OVERLOAD
- Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power on to recover Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power on to recover
- OVER VOLTAGE
- 30 ~ 34.8V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- DC OK SIGNAL
- PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V
- FAN CONTROL (Typ.)
- Load 35±15% or RTH2≧50℃ Fan on
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70 ℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85 ℃ , 10 ~ 95% RH
- TEMP. COEFFICIENT
- ± 0.03% /℃ (0 ~ 50 ℃ )
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 , AS/NZS 62368.1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 ℃ / 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class B Radiated BS EN/EN55032 Class B Harmonic current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact RF field BS EN/EN61000-4-3 Level 3, 10V/m EFT/ Burst BS EN/EN61000-4-4 Level 3, 2KV Surge BS EN/EN61000-4-5 Level 4, 4KV/Line-FG; 2KV/Line-Line Conducted BS EN/EN61000-4-6 Level 3, 10V Magnetic Field BS EN/EN61000-4-8 Level 4, 30A/m Voltage Dips and Interruptions BS EN/EN61000-4-11 95% dip 0.5 periods, 30% dip 25 periods, 95% interruptions 250 periods
OTHERS
- MTBF
- 1529.4K hrs min. Telcordia SR-332 (Bellcore) ; 201.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 199*105*41mm (L*W*H)
- PACKING
- 0.9Kg;15pcs/14.5Kg/0.84CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Diagnostic or biological facilities
- Test or measurement systems
- Telecommunication equipment
Downloads
Certificates7
Test reports1
FAQ
Can I use the HRP-300N-24 for 24V PLC systems, industrial I/O, or automation controls?
Yes, this model is built for constant voltage 24V output and is rated 336W with up to 14A. That makes it a fit for 24V industrial control systems and automation hardware designed around a 24V DC bus.
Is the HRP-300N-24 appropriate for 24V machine electronics or panel-based instrumentation?
It is appropriate when the equipment requires regulated 24V DC and the total load stays within 336W and 14A. Those specs align with many industrial electronics and instrumentation assemblies that standardize on 24V.
Can this 24V power supply run multiple 24V devices in a single enclosure?
Yes, as long as the combined 24V load does not exceed 14A or 336W. It is intended for constant voltage operation, so it works best in systems where all connected loads are designed for a 24V supply rail.
Is the HRP-300N-24 suitable for indoor factory use where temperatures can get very low or very high?
The operating temperature range is specified at -40°C to +70°C, with output derating at higher ambient temperatures per the derating curve. The provided specifications do not state an IP rating, so outdoor exposure capability is not confirmed from this data.
What is the difference between the HRP-300N-24 and the other HRP-300N models?
The HRP-300N series variants listed are 12V at 324W and 27A, 24V at 336W and 14A, 36V at 324W and 9A, and 48V at 336W and 7A. The HRP-300N-24 is the 24V option, so its key published output is 14A (336W rated) within the same 300W-class series.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HRP-300N Models
3 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HRP-300N-48 High Peak-Power Power Supply 300W 48V 7A | 336W | 48V | 7A | View |
| Mean Well HRP-300N-36 High Peak-Power Power Supply 300W 36V 9A | 324W | 36V | 9A | View |
| Mean Well HRP-300N-12 High Peak-Power Power Supply 300W 12V 27A | 324W | 12V | 27A | View |