Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well LRS-350-5 Power Supply 350W 5V 60A
4.7 (17 reviews)Overview
LRS-350-5 is the 5V output model of this series: rated current 60A, rated power 300W, typical efficiency 83.5%.
LRS-350 series is a 350W single-output enclosed type power supply with 30mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 3.3V, 4.2V, 5V, 12V, 15V, 24V, 36V and 48V. In addition to the high efficiency up to 89%, with the built-in long life fan LRS-350 can work under -25~+70β with full load. Delivering an extremely low no load power consumption (less than 0.75W), it allows the end system to easily meet the worldwide energy requirement. LRS-350 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as IEC/UL 62368-1. LRS-350 series serves as a high price-to-performance power supply solution for various industrial applications.
Features
- AC input range selectable by switch
- Withstand 300VAC surge input for 5 second
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Forced air cooling by built-in DC fan
- Built-in cooling Fan ON-OFF control
- 1U low profile
- Withstand 5G vibration test
- LED indicator for power on
- No load power consumption<0.75W
- 100% full load burn-in test
- High operating temperature up to 70β
- Operating altitude up to 5000 meters (Note.8)
- High efficiency, long life and high reliability
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 5V
- RATED CURRENT
- 60A
- CURRENT RANGE
- 0 ~ 60A
- RATED POWER
- 300W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 4.5 ~ 5.5V
- VOLTAGE TOLERANCENote.3
- Β±3.0%
- LINE REGULATIONNote.4
- Β±0.5%
- LOAD REGULATIONNote.5
- Β±2.0%
- SETUP, RISE TIME
- 1500ms, 50ms/230VAC 1500ms,50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 12ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC)
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 83.5%
- AC CURRENT (Typ.)
- 6.8A/115VAC 3.4A/230VAC
- INRUSH CURRENT (Typ.)
- 60A/115VAC 60A/230VAC
- LEAKAGE CURRENT
- <2mA / 240VAC
PROTECTION
- OVER LOAD
- 110 ~ 140% rated output power 3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
- OVER VOLTAGE
- 5.75 ~ 6.75V 3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
- OVER TEMPERATURE
- 3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
FUNCTION (Typ.)
- FAN ON/OFF CONTROL
- RTH3β§50β FAN ON, β¦40β FAN OFF
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +70β (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85β, 10 ~ 95% RH
- TEMP. COEFFICIENT
- Β±0.03%/β (0 ~ 50β)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
- OVER VOLTAGE CATEGORY
- β ’: According to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters
SAFETY & EMC (Note.9)
- SAFETY STANDARDS
- IEC/UL 62368-1,BSMI CNS15598-1,EAC TP TC 004,KC62368-1(for LRS-350-12/24 only),GB 4943.1, BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 12),BS EN/EN61558-1, BS EN61558-2-16 Designed by AS/NZS 61558.1/2.16, AS/NZS 62368.1,BS EN/EN62368-1,
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25β/ 70% RH
- EMC EMISSION
- Compliance to BSMI CNS15936, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-350-12/24 only)
- EMC IMMUNITY
- Compliance to BS EN/EN55035, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-350-12/24 only)
OTHERS
- MTBF
- 2099.9K hrs min. Telcordia SR-332 (Bellcore) ; 328.6Khrs min. MIL-HDBK-217F (25β)
- DIMENSION
- 215*115*30mm (L*W*H)
- PACKING
- 0.76Kg; 15pcs/12.4Kg/0.67CUFT
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25β of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Line regulation is measured from low line to high line at rated load.
- 5. Load regulation is measured from 0% to 100% rated load.
- 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
- 7. The 150% peak load capability is built in for up to 1 second for 12~48V.LRS-350 will enter hiccup mode if the peak load is delivered for over 1 second and will recover once it resumes to the rated current level(115VAC/230VAC).
- 8. The ambient temperature derating of 5β/1000m is needed for operating altitude greater than 2000m(6500ft).
- 9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to βEMI testing of component power supplies.β (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 10. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions: a) the end-devices is used within the European Union, and b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c) the power supply is: - installed in end-devices with average or continuous input power greater than 75W, or - belong to part of a lighting system Exception: Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2 a) professional equipment with a total rated input power greater than 1000W; b) symmetrically controlled heating elements with a rated power less than or equal to 200W
- 11. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
- 12. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.
Technical drawings
Typical applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
Downloads
FAQ
What systems can the LRS-350-5 power at 5V and 60A?
At 5V and 60A (300W), the LRS-350-5 is suited for powering logic backplanes in industrial PCs, embedded SBC clusters, legacy TTL and CMOS control boards, and high-current relay panels. Its 60A output supports dense multi-board systems with significant combined 5V current demand.
How does the LRS-350-5 output power compare to other LRS-350 series models?
Within the LRS-350 line, actual output power varies by voltage: LRS-350-3.3 (198W), LRS-350-4.2 (252W), LRS-350-5 (300W), LRS-350-12 (348W), LRS-350-15 (348W), LRS-350-24 (350.4W), LRS-350-36 (349.2W), LRS-350-48 (350.4W). The LRS-350-5 delivers 300W β more than the lower-voltage models at the same 60A rated current, but below the 12Vβ48V variants.
Does the LRS-350-5 accept both 120V and 230V AC input?
Yes. The LRS-350-5 accepts 90β132VAC or 180β264VAC, selected by a 115/230VAC input switch, making it compatible with North American 120V and European/international 230V mains once the switch is set to match the supply. With the switch on 230VAC it also accepts 240β370VDC.
Is the LRS-350-5 rated for high-vibration environments?
The LRS-350-5 is tested to 10β500Hz, 5G vibration and operates from -25Β°C to +70Β°C (with derating at higher ambient per the derating curve), making it suitable for industrial machinery enclosures subject to mechanical vibration. Humidity is rated 20β90% RH non-condensing and no IP rating is stated, so it requires a protective enclosure where moisture or contaminants are present.
Can the LRS-350-5 supply multiple 5V boards in parallel from a single unit?
A single LRS-350-5 can distribute its 60A output across multiple parallel 5V loads, provided total current draw stays at or below 60A (300W). Connecting loads in parallel on the same output rail is supported under constant-voltage operation.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other LRS-350 Models
3 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well LRS-350-12 Power Supply 350W 12V 29A | 348W | 12V | 29A | View |
| Mean Well LRS-350-24 Power Supply β 350W 24V 14.6A | 350.4W | 24V | 14.6A | View |
| Mean Well LRS-350-48 Power Supply 350W 48V 7.3A | 350.4W | 48V | 7.3A | View |
Customer reviews
Reviewed by 17 customers across the LRS series
-
Cheap and reliable enclosed PSU
Model: LRS-50-24Quantity: 10LRS-50-24 powers our sensor rack. Great price, no fuss.
-
Good budget option
Model: LRS-100-24Quantity: 4Runs a bit warm in a sealed box β add airflow. Otherwise solid.
-
Standardised on these
Model: LRS-350-24Quantity: 25Use LRS across all our retail fit-outs now.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your reviewβ¦
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.