MDR-20-24 is the 24V output model of this series: rated current 1A, rated power 24W, typical efficiency 84%.
Features
- Universal AC input/Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- Built in DC OK active signal
- LED indicator for power on
- No load power consumption<0.75W
- 100% full load burn-in test
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 1A
- CURRENT RANGE
- 0 ~ 1A
- RATED POWER
- 24W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 21.6 ~ 26.4V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±1.0%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIMENote.5
- 500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 20ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 84%
- AC CURRENT (Typ.)
- 0.55A/115VAC 0.35A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 20A/115VAC 40A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 160% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION
- DC OK ACTIVE SIGNAL (max.)
- 18 ~ 27V / 20mA
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- Ul508, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI CNS15598-1, AS/NZS 62368.1 , IS13252(Part1)/IEC60950-1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS15936 Class B
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55035,BS EN/EN61000-6-1,BS EN/EN61204-3, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 2780.8K hrs min. Telcordia SR-332 (Bellcore) ; 236.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 22.5*90*100mm (W*H*D)
- PACKING
- 0.17Kg; 72pcs/13.2Kg/1.04CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
Certificates4
Test reports1
FAQ
Can I use the MDR-20-24 for a 24V PLC control panel?
Yes, it is suitable for PLC control panels that need 24V DC up to 1A. Its 24W output is intended for lower-power 24V cabinet loads rather than larger automation assemblies.
Is the MDR-20-24 a good choice for industrial automation devices that run on 24V DC?
It can be used for industrial automation devices inside a DIN rail cabinet when the combined load does not exceed 1A at 24V. The ultra slim 22.5 mm width is useful in compact control enclosures.
Can this model be used in building management systems with 24V controls?
Yes, it fits building management panels that use 24V DC controls, interfaces, or similar low-power devices within a 24W budget. The 85-264VAC input supports a wide range of AC supply conditions.
What are the main differences between the MDR-20-24 and other 24V MDR models?
This datasheet covers the MDR-20 series, in which the MDR-20-24 is the only 24V model, rated 24W and 1A. The other versions are the MDR-20-5 (5V, 15W, 3A), MDR-20-12 (12V, 20W, 1.67A) and MDR-20-15 (15V, 20W, 1.34A), so the choice within this series comes down to the output voltage and current your load needs.
Is the MDR-20-24 suitable for enclosure use in industrial settings?
Yes, it is intended for use inside protected industrial enclosures and control cabinets. Its operating temperature range is -20°C to +70°C, with output derating at higher ambient temperatures according to the derating curve.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other MDR-20 Models
3 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well MDR-20-12 Single Output Industrial Power Supply 20W 12V 1.67A - DIN Rail | 20W | 12V | 1.67A | IP20 | View |
| Mean Well MDR-20-5 Single Output Industrial Power Supply 20W 5V 3A - DIN Rail | 15W | 5V | 3A | IP20 | View |
| Mean Well MDR-20-15 Single Output Industrial Power Supply 20W 15V 1.34A - DIN Rail | 20W | 15V | 1.34A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.