Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NID100-15 is the 15V output model of this series: rated current 6.5A, rated power 97.5W, typical efficiency 97%.
Features
- Economical open frame design
- Wide input range
- High efficiency up to 97%
- Remote ON / OFF control
- Compact size 2.0"×1.082"× 0.472"(SIP package)
- Protections: Short circuit / Overload / Over voltage
- -30~+85℃ wide working temperature
- Cooling by free air convection
- Comply to BS EN/EN55032 ClassA without additional components
- Trimming output (optional)
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- RATED CURRENT
- 6.5A
- RATED POWER
- 97.5W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- ±0.5%
- VOLTAGE TOLERANCE
- ±2.0%
- SWITCHING FREQUENCY (Typ.)
- 200KHz
- EXTERNAL CAPACITANCE LOAD (max.)
- 47uf/50V low ESR
INPUT
- VOLTAGE RANGE
- 20 ~ 53VDC
- NORMAL VOLTAGE
- 24VDC (or 48VDC)
- EFFICIENCY (Typ.) 24Vin
- 97%
- EFFICIENCY (Typ.) 48Vin
- 95%
- DC CURRENT Full load
- 4600mA/24VDC
- DC CURRENT No load
- 30mA
- PROTECTION
- Fuse recommended (8A)
PROTECTION
- OVERLOAD (Typ.)
- 120 ~ 300% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 17.5~ 21V Protection type : Shut off o/p voltage, clamp by TVS diode
- SHORT CIRCUIT
- All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed
FUNCTION
- REMOTE CONTROL
- Power on : 1.2VDC < R.C ~ com < 12VDC or open circuit ; power off : R.C ~ com < 0.4VDC or short circuit (PIN5,6,7,8 & PIN13)
ENVIRONMENT
- SAFETY STANDARDS
- EAC TP TC 004 approved
- WORKING TEMP.
- -30 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 85% RH non-condensing
- STORAGE TEMP.
- -30 ~ +105℃
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARD
- BS EN/EN62368-1(LVD)
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class A without external components,Class B with external components Radiated BS EN/EN55032 Class A without external components,Class B with external components - EMC IMMUNITY
-
BS EN/EN55035
Parameter Standard Test Level Radiated BS EN/EN61000-4-3 Level 2, 3V/m; criteria A EFT / Burst BS EN/EN61000-4-4 Level 2, 1KV; criteria A Surge BS EN/EN61000-4-5 Level 2, 1KV/Line-Line,criteria A Conducted BS EN/EN61000-4-6 Level 2, 3V; criteria A
OTHERS
- MTBF
- 17290.5K hrs min. Telcordia SR-332 (Bellcore) ; 1000.6K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 50.8*27.5*12mm or 2.0"*1.082"*0.472" inch (L*W*H)
- WEIGHT
- 35g;280psc/10.8Kg/0.94CUFT
Test conditions and notes4
- 1.All parameters are specified at normal input, rated load, 25℃ 70% RH Ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
Technical drawings
Downloads
Certificates3
Test reports1
FAQ
Can I use the NID100-15 for 15V industrial instrumentation or control electronics?
Yes, if the application needs constant 15V and the load stays within 6.5A and 97.5W. Its 20-53V input range makes it suitable where the source voltage is higher than the 15V output rail.
Is the NID100-15 appropriate for 15V embedded or communications hardware in a vehicle or machine system?
It can be, as long as the source is within 20-53V and the load requires regulated 15V output. The converter can provide up to 6.5A, with total output power capped at 97.5W.
Can this converter support 15V sensor, relay, or accessory loads in automation equipment?
It is designed for constant-voltage 15V output, so it fits grouped 15V loads that remain under 6.5A and 97.5W. The 50.8 × 27.5 × 12.0 mm form factor also helps in compact assemblies.
Would the NID100-15 be a fit for specialized 15V control boards where 12V or 24V would be wrong?
Yes, that is the main role of this model: converting a 20-53V source to a regulated 15V output. It is intended for loads that need 15V specifically and do not exceed 6.5A or 97.5W.
How does NID100-15 compare with the other NID100 converters?
NID100-15 provides 15V at 6.5A with 97.5W total output and accepts 20-53V input. The series also includes NID100-12 at 12V and 7.5A for 90W, NID100-24 at 24V and 4.2A for 100.8W with 30-53V input, and NID100-5 at 5V and 11A for 55W with 10.5-53V input.
Is the NID100-15 suitable for wide-temperature industrial environments?
The specified operating range is -30°C to +85°C, so the temperature capability is broad. No IP rating is given in the product data, so environmental sealing for outdoor or exposed use is not defined here.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NID100 Models
3 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well NID100-5 DC-DC Converter - 55W - 10.5~53V in 5V out 11A | 55W | 5V | 11A | IP20 | View |
| Mean Well NID100-24 DC-DC Converter - 100.8W - 30~53V in 24V out 4.2A | 100.8W | 24V | 4.2A | IP20 | View |
| Mean Well NID100-12 DC-DC Converter - 90W - 20~53V in 12V out 7.5A | 90W | 12V | 7.5A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.