Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
ODLC-45A-1050 is the model of this series: rated current 1050mA, rated power 45.15W, typical efficiency 85%.
ODLC-45 series is a 45W LED AC/DC driver featuring the constant current mode output with flicker free design.ODLC-45 operates from 90~295VAC and offers models with different rated current ranging between 350mA and 1400mA. Thanks to the efficiency up to 86%, with the fanless design, the entire series is able to operate for -20℃~+85℃ case temperature under free convection. The design of plastic housing and IP67 ingress protection level allows this series to fit indoor wet applications. ODLC-45 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for lighting system.
Features
- Constant Current mode output
- Flicker free design
- Plastic housing with class II design
- Built-in active PFC function
- No load power consumption<0.5W(Blank-Type), Standby power consumption<0.5W(DA-Type)
- IP67 rating for indoor or outdoor installations
- Function options: 2 in 1 dimming (dim-to-off); Auxiliary DC output; DALI
- 3 years warranty
Specifications
OUTPUT
- RATED CURRENT
- 1050mA
- RATED POWER
- 45.15W
- CONSTANT CURRENT REGIONNote.2
- 26 ~ 43V
- OPEN CIRCUIT VOLTAGE(max.)
- 63V
- CURRENT RIPPLE
- 5% max. @rated current
- CURRENT TOLERANCE
- ±7.0%
- SETUP TIMENote.4
- 500ms / 230VAC 1200ms/115VAC
- AUXILIARY DC OUTPUTNote.5
- Nominal 12V(deviation 11.4~12.6)@50mA for ODLC-45A only
INPUT
- VOLTAGE RANGENote.3
- 90 ~ 295VAC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/115VAC, PF>0.92/230VAC, PF>0.9/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20%(@load≧60%/230VAC; @load≧75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION” section)
- EFFICIENCY (Typ.)
- 85%
- AC CURRENT
- 0.6A/115VAC 0.4A/230VAC 0.3A/277VAC
- INRUSH CURRENT (Typ.)
- COLD START 30A(twidth=100μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- NO LOAD/STANDBY POWER CONSUMPTION
- No load power consumption<0.5W for Blank-Type,<1.2W for ODLC-45A Standby power consumption<0.5W for DA-Type
PROTECTION
- SHORT CIRCUIT
- Hiccup mode,auto-recovery after fault condition is removed for DA type; Hiccup mode,re-power on to recovery for other type
ENVIRONMENT
- WORKING TEMP.
- Tcase=-20 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
- MAX. CASE TEMP.
- Tcase=+85℃
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 40℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750(type”HL”),CSA C22.2 NO.250.13-12;ENEC BS EN/EN61347-1 & BS EN/EN61347-2-13 independent, BS EN/EN62384; BIS IS15885( for ODLC-45-700,1050,700DA,1050DA only), EAC TP TC 004,IP67 approved
- DALI STANDARDS
- Compliance to IEC62386-101, 102 for DA-Type only
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load≧60%) ; BS EN/EN61000-3-3, GB17743,GB17625.1,EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level(surge immunity: Line-Line:1KV),EAC TP TC 020
OTHERS
- MTBF
- 3513.4K hrs min. Telcordia SR-332 (Bellcore) ;340.8K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 111*77*28.5mm(L*W*H)
- PACKING
- 0.42Kg; 24pcs/ 11Kg/ 0.72CUFT
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Please refer to "DRIVING METHODS OF LED MODULE".
- 3. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 4. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.
- 5. Aux. 12V will be damaged with short circuit; It will not be available when output voltage is not in constant current region or output no load condition.
- 6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
- 7. The DALI version driver does not support the bit 1: Lamp failure in the Command 144 Query status of the DALI standard.
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 9. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
Technical drawings
Typical applications
- LED panel lighting
- LED flood lighting
- Indoor LED lighting
- Industrial lighting
Downloads
Certificates7
Test reports1
Catalogues1
FAQ
Can I use the ODLC-45A-1050 for a 1050mA LED downlight?
Yes, this driver is built for constant current LED loads at 1050mA. It is a fit for LED downlights when the fixture's LED forward voltage falls within the 26-43V constant current range and the load stays within 45.15W.
Is the ODLC-45A-1050 suitable for a small high-power LED array?
It can be used for a small LED array that is designed for 1050mA constant current operation. The array voltage must stay within 26-43V, and the total load must remain within the 45.15W rating.
Can this driver power signage lighting modules?
It can work with signage modules only if those modules are constant current types rated for 1050mA. Many signage products are constant voltage instead, so this model should only be used where the module spec matches 1050mA and 26-43V.
How do I know if my LEDs are compatible with the ODLC-45A-1050?
This is a constant current driver with a 26-43V output range at 1050mA, so the LED load must be designed for constant current operation rather than constant voltage. The number of LEDs depends on each LED's forward voltage, not on a fixed LED count.
Is the ODLC-45A-1050 appropriate for wet or harsh locations?
The housing is rated IP67, so it is intended for waterproof applications where dust and water resistance are required. It is also specified for operation from -20°C to +85°C, which supports a wide range of indoor and outdoor environments.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other ODLC-45A Models
4 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well ODLC-45A-700 Power Supply 45W 700mA (Auxiliary DC output) | 44.8W | 64V | 0.7A | IP67 | View |
| Mean Well ODLC-45A-500 Power Supply 45W 500mA (Auxiliary DC output) | 45W | 90V | 0.5A | IP67 | View |
| Mean Well ODLC-45A-350 Power Supply 45W 350mA (Auxiliary DC output) | 33.25W | 95V | 0.35A | IP67 | View |
| Mean Well ODLC-45A-1400 Power Supply 45W 1400mA (Auxiliary DC output) | 44.8W | 32V | 1.4A | IP67 | View |