Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PLC-60-15 is the 15V output model of this series: rated current 4A, rated power 60W, typical efficiency 86%.
Features
- Universal AC input / Full range
- High efficiency up to 89%
- Adjustable output voltage and current level
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- Fully isolated plastic case with terminal block style of I/O
- Built-in active PFC function, comply with BS EN/EN61000-3-2 class C (≧75% load)
- Class 2 power unit
- Pass LPS
- 100% full load burn-in test
- High reliability
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- CONSTANT CURRENT REGIONNote.6
- 10.5 ~15V
- RATED CURRENT
- 4A
- CURRENT RANGE
- 0 ~ 4A
- RATED POWER
- 60W
- RIPPLE & NOISE (max.)Note.2
- 2.4Vp-p
- VOLTAGE ADJ. RANGENote.5
- 14.5 ~ 16.2V
- CURRENT ADJ. RANGENote.5
- 3 ~ 4.12A
- VOLTAGE TOLERANCENote.3
- ±10%
- LINE REGULATION
- ±3.0%
- LOAD REGULATION
- ±5.0%
- SETUP TIME
- 500ms / 230VAC 3000ms / 115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.92/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧75% at 115VAC/230VAC input
- EFFICIENCY (Typ.)
- 86%
- AC CURRENT (Typ.)
- 0.8A/115VAC 0.4A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 35A(twidth=35μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVER CURRENT
- 95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed.
- OVER VOLTAGE
- 17.5 ~ 21V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +50℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL1310, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧75% load) ; BS EN/EN61000-3-3,EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024,BS EN/EN61547, light industry level ,EAC TP TC 020
OTHERS
- MTBF
- 3445.4K hrs min. Telcordia SR-332 (Bellcore) 515.0Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 181.5*62*35mm (L*W*H)
- PACKING
- 0.41Kg; 30pcs/13.3Kg/0.67CUFT
Certifications & ratings
- Marked features
- LPS, FC
Test conditions and notes11
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
- 5. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
- 6. Please refer to "DRIVING METHODS OF LED MODULE".
- 7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
- 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 11. This product is not suitable for LED lighting applications in China.(It is recommended to use the LPF/NPF/XLG/XLC/XLN series in China)
Technical drawings
Typical applications
- Suitable for LED lighting and moving sign applications (Note.2)
- Compliance to worldwide safety regulations for lighting
- 2 years warranty
Downloads
Datasheet1
Certificates6
Catalogues1
FAQ
What applications is the Mean Well PLC-60-15 best suited for?
The PLC-60-15 is designed for LED lighting and moving sign applications that need a 15V DC power source. Its 60W output and built-in constant current limiting make it a practical choice for systems that drive LEDs in its 10.5-15V constant current region.
What are the main electrical ratings of the PLC-60-15?
This model is rated for 60W output power with a 15V DC output and 4A rated current. It also supports 90-264VAC universal AC input and includes power factor correction, with PF>0.92 at 115VAC and PF>0.9 at 230VAC at full load.
Does the PLC-60-15 support dimming control?
No, the PLC-60-15 does not include a dimming control function. If your project requires dimming, you would need to compare it with a different LED driver model that specifically lists dimming support.
What makes the PLC-60-15 different from a basic fixed-output power supply?
This model combines constant voltage output with built-in constant current limiting, which is useful in LED-related applications. It also includes PFC, the LPS marking, and a full set of protections including short circuit, over current, over voltage, and over temperature.
Can the output of the PLC-60-15 be adjusted?
Yes, the PLC-60-15 includes adjustable output voltage and current level capability. That gives buyers some flexibility when selecting this model for applications that need a 15V nominal output with tunable operating limits.
Is the PLC-60-15 suitable for demanding operating environments?
It is rated for operation from -30°C to 50°C (with derating per the derating curve), which supports use across a fairly wide temperature range. The unit is also rated for 20-95% RH non-condensing humidity and 2G vibration at 10-500Hz.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other PLC-60 Models
6 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well PLC-60-48 Power Supply 60W 48V - PFC 1.3A | 62.4W | 48V | 1.3A | IP20 | View |
| Mean Well PLC-60-36 Power Supply 60W 36V - PFC 1.7A | 61.2W | 36V | 1.7A | IP20 | View |
| Mean Well PLC-60-27 Power Supply 60W 27V - PFC 2.3A | 62.1W | 27V | 2.3A | IP20 | View |
| Mean Well PLC-60-24 Power Supply 60W 24V - PFC 2.5A | 60W | 24V | 2.5A | IP20 | View |
| Mean Well PLC-60-20 Power Supply 60W 20V - PFC 3A | 60W | 20V | 3A | IP20 | View |
| Mean Well PLC-60-12 Power Supply 60W 12V - PFC 5A | 60W | 12V | 5A | IP20 | View |