Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PSC-160A-C is the CH1: 13.8V / CH2: 13.8V output model of this series: rated current CH1: 7.6A / CH2: 4A, rated power 160W, typical efficiency 88%.
PSC-160 series is a 160W AC/DC security power supply, allowing the universal input range between 90VAC and 264VAC and incorporating the built-in PFC function. In addition to the primary output, there is a charger output, with the smaller rated current, that provides the backup power supply application the security access systems require. PSC-160 delivers an efficiency up to 90%; it can operate with air convection under -20℃ through 70℃. This series is designed with thorough alarm features, including AC OK and battery low signaling; moreover, the relay contact is provided to facilitate users' system designs. PSC-160 is available in the PCB type or the enclosed type with L-Bracket and cover.
Features
- Universal AC input / Full range
- Built-in active PFC function
- 6"x3" compact PCB size
- Models with L-Bracket and cover available (PSC-160x-C, x=A,B)
- Protections: Short circuit / Overload / Over voltage
- Battery low protection / Battery reverse polarity protection by fuse
- Relay contact signal output for AC OK and Battery Low
- Cooling by free air convection
- 100% full load burn-in test
- 2 years warranty
Specifications
OUTPUT
- OUTPUT NUMBER
- CH1 / CH2
- DC VOLTAGE
- CH1: 13.8V / CH2: 13.8V
- RATED CURRENT
- CH1: 7.6A / CH2: 4A
- CURRENT RANGE
- CH1: 0 ~ 11.6A / CH2: --------
- RATED POWER
- 160W
- RIPPLE & NOISE (max.)Note.2
- CH1: 150mVp-p / CH2: --------
- VOLTAGE ADJ. RANGE
- CH1: 12 ~ 15V
- VOLTAGE TOLERANCENote.3
- CH1: ±1.0% / CH2: --------
- LINE REGULATION
- CH1: ±0.5% / CH2: --------
- LOAD REGULATION
- CH1: ±0.5% / CH2: --------
- SETUP, RISE TIMENote.4
- 2000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 40ms/230VAC 40ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.95/230VAC PF≧0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 88%
- AC CURRENT (Typ.)
- 2.5A/115VAC 1.5A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 35A/115VAC 70A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- CH1:14.49 ~ 18.63V Protection type : Shut down o/p voltage, re-power on to recover
- BATTERY CUT OFF
- 10±0.5V
ALARM FUNCTION
- AC OKNote.5
- Relay contact output, ON : AC OK ; OFF : AC Fail ; Max. rating : 30V / 1A
- BATTERY LOW
- Relay contact output, OFF : Battery OK ; ON : Battery Low ; Max. rating : 30V / 1A ; Battery low voltage : < 11V
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -20 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0~45℃) on CH1 output
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 2005.3K hrs min. Telcordia SR-332 (Bellcore) ; 257.1K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- PCB:152.4*76.2*32mm (L*W*H) ; Enclosed type:155.4*85*37mm (L*W*H)
- PACKING
- PCB:0.35Kg;42pcs/15.7Kg/1.02CUFT ; Enclosed type: 0.45Kg;32pcs/15.4Kg/0.83CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 5. Please refer to suggested Application 2.(2)、(3) in page 3.
- 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Security system
- Emergency lighting system
- Alarm system
- UPS system
- Central monitoring system
- Access systems
Downloads
Certificates7
Catalogues1
FAQ
Can the PSC-160A-C power a higher-load 13.8V battery-backed automation cabinet?
Yes, it is a 13.8V constant-voltage model with UPS function and a 160W rating (7.6A load output plus a 4A battery charger output), so it fits higher-load battery-backed automation cabinets designed around that DC level, as long as the total stays within that rating.
Is the PSC-160A-C suitable for 13.8V communications or dispatch equipment with standby power?
It can be suitable for communications or dispatch equipment that uses a 13.8V DC bus and stays within 7.6A and 160W. The UPS function is relevant where the system is intended to maintain operation from a battery-backed supply.
Would the PSC-160A-C be appropriate for embedded controllers that need more than 4.75A at 13.8V?
Yes, because this model is rated for 7.6A at 13.8V on its load output (current range 0-11.6A), plus a 4A battery charger output. It is a fit when the load exceeds 4.75A but the total, including battery charging, stays within 160W.
Can the PSC-160A-C be used in equipment sold across multiple AC power regions?
Yes, the input range is 90-264VAC, which supports systems intended for varied AC mains environments. The DC output is 13.8V (adjustable 12-15V) with a 7.6A rated load current.
What separates the PSC-160A-C from the rest of the PSC charger family?
The -C suffix means the enclosed type with L-bracket and cover (155.4x85x37mm); the PSC-160A is the same 13.8V, 160W unit as a bare PCB (152.4x76.2x32mm), both rated 7.6A for the load plus 4A charging at 88% efficiency. The PSC-160B and PSC-160B-C are the 27.6V versions at 3.8A plus 2A charging and 90% efficiency. Smaller PSC models are not covered by this datasheet.
Is the PSC-160A-C rated for outdoor conditions?
The temperature specification is -20°C to +70°C, so it is rated for a wide operating range. The provided specs do not include an IP rating, so outdoor suitability is not confirmed by the product data shown here.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.