Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PSC-35A-C is the CH1: 13.8V / CH2: 13.8V output model of this series: rated current CH1: 1.7A / CH2: 0.9A, rated power 35.88W, typical efficiency 84%.
PSC-35 series is a 35W AC/DC security power supply, allowing the universal input range between 90VAC and 264VAC and incorporating the built-in PFC function. In addition to the primary output, there is a charger output, with a smaller rated current, providing the backup application the security access systems normally need. PSC-35 delivers an efficiency up to 86%; it can operate with air convection under -30℃ through 70℃. This series is designed with thorough alarm features, including AC OK and battery low signaling; moreover, the relay contact is provided to facilitate users system designs. PSC-35 is available in the PCB type (3.3" x 2") or the enclosed type with L-Bracket and cover.
Features
- Universal AC input / Full range
- 3.3"x2" compact PCB size
- Models with L-Bracket and cover available (PSC-35x-C, x=A,B)
- Protections: Short circuit / Overload / Over voltage
- Battery low protection / Battery reverse polarity protection by fuse
- Alarm signal for AC OK and Battery low
- Cooling by free air convection
- 100% full load burn-in test
- 2 years warranty
Specifications
OUTPUT
- OUTPUT NUMBER
- CH1 / CH2
- DC VOLTAGE
- CH1: 13.8V / CH2: 13.8V
- RATED CURRENT
- CH1: 1.7A / CH2: 0.9A
- CURRENT RANGE
- CH1: 0 ~ 2.6A / CH2: --------
- RATED POWER
- 35.88W
- RIPPLE & NOISE (max.)Note.2
- CH1: 120mVp-p / CH2: --------
- VOLTAGE ADJ. RANGE
- CH1: 12 ~ 15V
- VOLTAGE TOLERANCENote.3
- CH1: ±1.0% / CH2: --------
- LINE REGULATION
- CH1: ±0.5% / CH2: --------
- LOAD REGULATION
- CH1: ±0.5% / CH2: --------
- SETUP, RISE TIMENote.4
- 800ms, 50ms/230VAC 1600ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 10ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 84%
- AC CURRENT (Typ.)
- 0.75A/115VAC 0.5A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 20A/115VAC 40A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- CH1:14.49 ~ 19.5V Protection type : Shut down O/P Voltage, repower on to recover
- BATTERY CUT OFF
- 10±0.5V
FUNCTION
- AC OK
- TTL open collector output, ON : AC OK ; OFF : AC Fail ; Ice : max. 30mA@ 50VDC
- BATTERY LOW
- TTL open collector output, ON : Battery Low ; OFF : Battery OK ; Ice : max. 30mA@ 50VDC Battery low voltage : < 11V
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -20 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0~50℃) on CH1 output
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 4114.3K hrs min. Telcordia SR-332 (Bellcore) ; 658.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- PCB:84.6*50.8*24mm (L*W*H) ; Enclosed type:86.4*59.6*30mm (L*W*H)
- PACKING
- PCB:0.092Kg;90pcs/9.28Kg/0.97CUFT ; Enclosed type: 0.145Kg;100pcs/15.5Kg/1.03CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 5. Heat sink HS1,HS2 can not be shorted.
- 6. Heat sink HS1 must have safety isolation distance with system case.
- 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Security system
- Emergency lighting system
- Alarm system
- UPS system
- Central monitoring system
- Access systems
Downloads
Certificates7
Test reports1
Catalogues1
FAQ
Can I use the PSC-35A-C in a small 12V industrial standby power application?
It delivers 13.8V constant-voltage output at up to 1.7A, with 35.88W total output power. That makes it a fit for smaller 12V-class standby applications that need UPS function support and stay within those limits.
Is the PSC-35A-C suitable for compact embedded or control devices with 12V battery backup?
Yes, for lower-power systems it offers 13.8V and 1.7A from a 90-264VAC input range. It fits embedded, control, or instrumentation use cases where the required charging or backup power does not exceed 35.88W.
Can the PSC-35A-C be used where a covered version of a 13.8V charger is preferred?
This model has the same 13.8V, 1.7A, and 35.88W electrical rating as the PSC-35A, and the feature list notes that -C types are models with L-bracket and cover available. It is relevant when the application calls for that covered variant while staying in the same low-power 12V-class range.
Can the PSC-35A-C be used outdoors or in washdown areas?
The listed operating temperature range is -30°C to +70°C, but the provided specs do not show an IP rating. Without an IP rating in the spec set, outdoor or washdown use should not be assumed.
What is the difference between PSC-35A-C and the other 13.8V PSC options?
PSC-35A-C is rated at 35.88W, 13.8V, and 1.7A, while PSC-60A and PSC-60A-C are 59.34W and 2.8A, PSC-100A and PSC-100A-C are 100.05W and 4.75A, and PSC-160A and PSC-160A-C are 160W and 7.6A. Compared with PSC-35A, the PSC-35A-C keeps the same electrical rating but has enclosed dimensions of 86.4 × 59.6 × 30.0 mm and weight of 0.145 kg.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.