Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PSC-35B-C is the CH1: 27.6V / CH2: 27.6V output model of this series: rated current CH1: 0.85A / CH2: 0.45A, rated power 35.88W, typical efficiency 86%.
PSC-35 series is a 35W AC/DC security power supply, allowing the universal input range between 90VAC and 264VAC and incorporating the built-in PFC function. In addition to the primary output, there is a charger output, with a smaller rated current, providing the backup application the security access systems normally need. PSC-35 delivers an efficiency up to 86%; it can operate with air convection under -30℃ through 70℃. This series is designed with thorough alarm features, including AC OK and battery low signaling; moreover, the relay contact is provided to facilitate users system designs. PSC-35 is available in the PCB type (3.3" x 2") or the enclosed type with L-Bracket and cover.
Features
- Universal AC input / Full range
- 3.3"x2" compact PCB size
- Models with L-Bracket and cover available (PSC-35x-C, x=A,B)
- Protections: Short circuit / Overload / Over voltage
- Battery low protection / Battery reverse polarity protection by fuse
- Alarm signal for AC OK and Battery low
- Cooling by free air convection
- 100% full load burn-in test
- 2 years warranty
Specifications
OUTPUT
- OUTPUT NUMBER
- CH1 / CH2
- DC VOLTAGE
- CH1: 27.6V / CH2: 27.6V
- RATED CURRENT
- CH1: 0.85A / CH2: 0.45A
- CURRENT RANGE
- CH1: 0 ~ 1.3A / CH2: --------
- RATED POWER
- 35.88W
- RIPPLE & NOISE (max.)Note.2
- CH1: 240mVp-p / CH2: --------
- VOLTAGE ADJ. RANGE
- CH1: 24 ~ 29V
- VOLTAGE TOLERANCENote.3
- CH1: ±1.0% / CH2: --------
- LINE REGULATION
- CH1: ±0.5% / CH2: --------
- LOAD REGULATION
- CH1: ±0.5% / CH2: --------
- SETUP, RISE TIMENote.4
- 800ms, 50ms/230VAC 1600ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 10ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 86%
- AC CURRENT (Typ.)
- 0.75A/115VAC 0.5A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 20A/115VAC 40A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- CH1:28.98 ~ 39.5V Protection type : Shut down O/P Voltage, repower on to recover
- BATTERY CUT OFF
- 20±1V
FUNCTION
- AC OK
- TTL open collector output, ON : AC OK ; OFF : AC Fail ; Ice : max. 30mA@ 50VDC
- BATTERY LOW
- TTL open collector output, ON : Battery Low ; OFF : Battery OK ; Ice : max. 30mA@ 50VDC Battery low voltage : < 22V
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -20 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0~50℃) on CH1 output
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 4114.3K hrs min. Telcordia SR-332 (Bellcore) ; 658.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- PCB:84.6*50.8*24mm (L*W*H) ; Enclosed type:86.4*59.6*30mm (L*W*H)
- PACKING
- PCB:0.092Kg;90pcs/9.28Kg/0.97CUFT ; Enclosed type: 0.145Kg;100pcs/15.5Kg/1.03CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 5. Heat sink HS1,HS2 can not be shorted.
- 6. Heat sink HS1 must have safety isolation distance with system case.
- 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Security system
- Emergency lighting system
- Alarm system
- UPS system
- Central monitoring system
- Access systems
Downloads
Certificates7
Test reports1
Catalogues1
FAQ
Can I use the PSC-35B-C for a compact 24V control or automation backup application?
It is rated for 27.6V constant-voltage output at up to 0.85A, with 35.88W total output power. That suits lower-power 24V-class control or automation backup applications that use a 27.6V charging level.
Is the PSC-35B-C appropriate for small embedded systems that use a 24V-class battery-backed supply?
For low-power embedded equipment, this model supplies 27.6V and 0.85A from a 90-264VAC input range. It is a fit where the battery charging or standby requirement remains within 35.88W.
Can the PSC-35B-C be used when I need a covered version of a 27.6V low-power charger?
Yes, the feature list states that -C types are models with L-bracket and cover available, while this version keeps the same 27.6V, 0.85A, and 35.88W rating as PSC-35B. It is intended for the same low-power 24V-class applications with that covered variant format.
Is the PSC-35B-C suitable for outdoor enclosures?
The listed operating temperature range is -30°C to +70°C, but no IP rating is provided in the supplied specs. Without an IP rating, outdoor exposure or weather resistance should not be assumed from this information alone.
What separates the PSC-35B-C from the other 27.6V PSC models?
PSC-35B-C is rated at 35.88W, 27.6V, and 0.85A, while PSC-60B and PSC-60B-C are 59.34W and 1.4A, PSC-100B and PSC-100B-C are 100.74W and 2.4A, and PSC-160B and PSC-160B-C are 160W and 3.8A. Compared with PSC-35B, the PSC-35B-C keeps the same electrical rating but has dimensions of 86.4 × 59.6 × 30.0 mm and weight of 0.145 kg.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.