Overview
PSC-60B-C is the model of this series: rated power 59.34W, typical efficiency 84%.
Features
- Universal AC input / Full range
- Models with L-Bracket and cover available (PSC-60x-C, x=A,B)
- Protections: Short circuit / Overload / Over voltage
- Battery low protection / Battery reverse polarity protection by fuse
- Alarm signal for AC OK and Battery reverse low
- Cooling by free air convection
- 100% full load burn-in test
- 2 years warranty
Specifications
OUTPUT
- OUTPUT NUMBER
- CH1, CH2
- DC VOLTAGE (CH1)
- 27.6V
- DC VOLTAGE (CH2)
- 27.6V
- RATED CURRENT (CH1)
- 1.4A
- RATED CURRENT (CH2)
- 0.75A
- CURRENT RANGE (CH1)
- 0 ~ 2.15A
- CURRENT RANGE (CH2)
- --------
- RATED POWER
- 59.34W
- RIPPLE & NOISE (max.) (CH1)Note.2
- 240mVp-p
- RIPPLE & NOISE (max.) (CH2)Note.2
- --------
- VOLTAGE ADJ. RANGE
- CH1: 24 ~ 29V
- VOLTAGE TOLERANCE (CH1)Note.3
- ±1.0%
- VOLTAGE TOLERANCE (CH2)Note.3
- --------
- LINE REGULATION (CH1)
- ±0.5%
- LINE REGULATION (CH2)
- --------
- LOAD REGULATION (CH1)
- ±0.5%
- LOAD REGULATION (CH2)
- --------
- SETUP, RISE TIMENote.4
- 800ms, 50ms/230VAC 1600ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 10ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 84%
- AC CURRENT (Typ.)
- 1.6A/115VAC 1A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 30A/115VAC 60A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- CH1:28.98 ~ 37.26V Protection type : Hiccup mode, recovers automatically after fault condition is removed
- BATTERY CUT OFF
- 21±1V
FUNCTION
- AC OK
- TTL open collector output, ON : AC OK ; OFF : AC Fail ; Ice : max. 30mA@ 50VDC
- BATTERY LOW
- TTL open collector output, ON : Battery Low ; OFF : Battery OK ; Ice : max. 30mA@ 50VDC
- Battery low voltage
- < 22V
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -20 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0~50℃) on CH1 output
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCENote 7
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 3681.4K hrs min. Telcordia SR-332 (Bellcore) ; 589.7K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- PCB:101.6*50.8*29mm (L*W*H) ; Enclosed type:103.4*62*37mm (L*W*H)
- PACKING
- PCB:0.13Kg; 96pcs/13.5Kg/1.39CUFT ; Enclosed type:0.29Kg; 45pcs/14Kg/0.63CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 5. Heat sink HS1,HS2 can not be shorted.
- 6. Heat sink HS1 must have safety isolation distance with system case.
- 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
Certificates8
Catalogues1
FAQ
Can I use the PSC-60B-C for a 24V battery-backed PLC, relay, or automation panel?
The PSC-60B-C delivers 27.6V constant-voltage output at up to 1.4A, with 59.34W total power. That makes it a candidate for smaller 24V-class backup applications where the connected control load stays within those limits.
Is the PSC-60B-C a fit for compact 24V embedded or industrial monitoring systems?
It can be used where the equipment is designed for a 27.6V source and needs no more than 1.4A or 59.34W. The built-in UPS function is useful in monitoring or automation systems that need charger and backup capability in one device.
Can the PSC-60B-C be used for lower-power 24V communications equipment?
Yes, it is positioned for lower-power 24V-class loads that are compatible with 27.6V constant-voltage output and remain within 1.4A. The -C version also has a larger 103.4 × 62.0 × 37.0 mm form factor and 0.29 kg weight, which should be checked against available panel space.
Is the PSC-60B-C suitable for outdoor cabinets or temperature-variable indoor areas?
The published operating temperature range is -20°C to +70°C, so it can handle a broad ambient range. Since no IP rating is listed in the provided specs, outdoor exposure or hose-down environments should not be assumed.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.