Mean Well RPS-75-48 Green Power Supply 76.8W 48V 1.6A - Medical Power Supply

5" x 3" compact sizemedical safety approvedno load power consumption < 0.75Wlifetime > 80K hours
SKU RPS-75-48
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

RPS-75-48 is the 48V output model of this series: rated current 1.6A, rated power 76.8W, typical efficiency 86%.

RPS-75 is a 75W highly reliable green PCB type medical power supply with a high power density on the 5” by 3” footprint. It accepts 90~264VAC input and offers various output voltages between 3.3V and 48V. The working efficiency is up to 86% and the extremely low no load power consumption is down below 0.75W. RPS-75 is able to be used for ClassⅠ (with FG) system design. The extremely low leakage current is less than 150μA. In addition, it conforms to international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.

Features

  • 5"×3" compact size
  • Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1
  • Suitable for BF application with appropriate system consideration
  • 75W convection,100W force air
  • EMI Class B for ClassⅠconfiguration
  • No load power consumption<0.75W
  • Remote sense functiom
  • Protections: Short circuit / Overload / Over voltage
  • Lifetime > 80K hours
  • Operating altitude up to 3000 meters
  • 3 years warranty

Specifications

RPS-75-48Specifications from the official datasheet (2024-11-22 edition)

OUTPUT

DC VOLTAGE
48V
RATED CURRENT
1.6A
CURRENT RANGE
0 ~ 2.1A
RATED POWER
76.8W
PEAK LOAD (23.5CFM)
100.8W
RIPPLE & NOISE (max.)Note.2
100mVp-p
VOLTAGE ADJ. RANGE
45.6 ~ 52.8V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±1.0%
SETUP, RISE TIME
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
90ms/230VAC 20ms/115VAC at full load

INPUT

VOLTAGE RANGE
90 ~ 264VAC 127 ~370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
86%
AC CURRENT (Typ.)
1.5A/115VAC 1A/230VAC
INRUSH CURRENT (Typ.)
COLD START 25A/115VAC 50A/230VAC
LEAKAGE CURRENT(max.)Note.4
Earth leakage current < 150μA/264VAC , Touch current < 100μA/264VAC

PROTECTION

OVERLOAD
140 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE
55.2 ~ 64.8V Protection type : Shut down o/p voltage, re-power to recover

ENVIRONMENT

WORKING TEMP.
-20 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
OPERATING ALTITUDENote.5
3000 meters

SAFETY & EMC

SAFETY STANDARDS
IEC 60601-1:2005+A1+A2, TUV BS EN/ EN 60601-1:2006+A1+A12+A2, ANSI/AAMI ES60601-1:2005+A2 CAN/CSA C22.2 No. 60601-1:2014+A2, EAC TP TC 004 approved; Design refer to BS EN/EN60335-1(by request)
ISOLATION LEVEL
Primary-Secondary:2xMOPP, Primary-Earth:1xMOPP
WITHSTAND VOLTAGE
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
Conducted emissionBS EN/EN55011 (CISPR11)Class B
Radiated emissionBS EN/EN55011 (CISPR11)Class B
Harmonic currentBS EN/EN61000-3-2Class A
Voltage flickerBS EN/EN61000-3-3
EMC IMMUNITY

BS EN/EN55035, BS EN/EN60601-1-2

ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 4, 15KV air; Level 4, 8KV contact
RF field susceptibilityBS EN/EN61000-4-3Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz )
EFT burstsBS EN/EN61000-4-4Level 3, 2KV
Surge susceptibilityBS EN/EN61000-4-5Level 4, 4KV/Line-FG; 2KV/Line-Line
Conducted susceptibilityBS EN/EN61000-4-6Level 3, 10V
Magnetic field immunityBS EN/EN61000-4-8Level 4, 30A/m
Voltage dip, interruptionBS EN/EN61000-4-11100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods

OTHERS

MTBF
2837.6K hrs min. Telcordia SR-332 (Bellcore) ; 446.8K hrs min. MIL-HDBK-217F (25℃)
DIMENSION (L*W*H)
127*76.2*31mm or 5" * 3" *1.22" inch
PACKING
0.26Kg; 63pcs/16.3Kg/1.28CUFT
Test conditions and notes7
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Touch current was measured from primary input to DC output.
  5. 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  6. 6. Heat Sink HS1,HS2,HS3 can not be shorted.
  7. 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

Technical drawings

RPS-75-48 Block Diagram
Block Diagram
RPS-75-48 Derating Curve
Derating Curve
RPS-75-48 Mechanical Specification
Mechanical Specification

Typical applications

  • Oral irrigator
  • Hemodialysis machine
  • Medical computer monitors
  • Sleep apnea devices

Downloads

FAQ

Can I use the RPS-75-48 for a 48V industrial controller or PLC-related device?

This model is intended for 48V DC equipment that needs a constant voltage supply and stays within 1.6A and 76.8W. It can fit industrial control, automation, or embedded hardware that is specified for 48V input within that load range.

Is this power supply suitable for 48V medical or laboratory equipment?

It can be used with 48V medical or lab equipment that requires constant voltage and draws no more than 1.6A or 76.8W. The unit is described as medical safety approved, which can matter for regulated equipment builds.

Can the RPS-75-48 power a small 48V embedded or telecom device?

Yes, if the device requires 48V DC and its total load does not exceed 1.6A or 76.8W. That makes it more appropriate for lower-power 48V electronics than for heavier 48V loads.

Is the RPS-75-48 appropriate for indoor or outdoor use?

The listed operating temperature is -20°C to +70°C, so the temperature range is broad for indoor equipment enclosures. No IP rating is listed, so it should be treated as a power supply for protected indoor installations rather than exposed wet or outdoor locations.

How does the RPS-75-48 compare with the other RPS-75 models?

Within the RPS-75 family, the available outputs are RPS-75-3.3 at 49.5W and 3.3V 15A, RPS-75-5 at 70W and 5V 14A, RPS-75-12 at 75.6W and 12V 6.3A, RPS-75-15 at 75W and 15V 5A, RPS-75-24 at 76.8W and 24V 3.2A, RPS-75-36 at 75.6W and 36V 2.1A, and RPS-75-48 at 76.8W and 48V 1.6A. The main difference is the output voltage and current rating for each model.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8431167471915, "variants" :[{ "context":"default", "variant_id": 45665607713067, "sku":"RPS-75-48", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well RPS-75-48 Green Power Supply W 48V 1.6A - Medical Power Supply
Mean Well

Mean Well RPS-75-48 Green Power Supply 76.8W 48V 1.6A - Medical Power Supply

RPS-75-48 is the 48V output model of this series: rated current 1.6A, rated power 76.8W, typical efficiency 86%.

RPS-75 is a 75W highly reliable green PCB type medical power supply with a high power density on the 5” by 3” footprint. It accepts 90~264VAC input and offers various output voltages between 3.3V and 48V. The working efficiency is up to 86% and the extremely low no load power consumption is down below 0.75W. RPS-75 is able to be used for ClassⅠ (with FG) system design. The extremely low leakage current is less than 150μA. In addition, it conforms to international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.

Features

  • 5"×3" compact size
  • Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1
  • Suitable for BF application with appropriate system consideration
  • 75W convection,100W force air
  • EMI Class B for ClassⅠconfiguration
  • No load power consumption<0.75W
  • Remote sense functiom
  • Protections: Short circuit / Overload / Over voltage
  • Lifetime > 80K hours
  • Operating altitude up to 3000 meters
  • 3 years warranty

Typical applications

  • Oral irrigator
  • Hemodialysis machine
  • Medical computer monitors
  • Sleep apnea devices