RSD-100C-12 is the 12V output model of this series: rated current 8.4A, rated power 100.8W, typical efficiency 91%.
Features
- Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
- 2:1 wide input range
- Protections: Short circuit / Overload / Over voltage / Input reverse polarity
- 4000VDC I/O isolation
- Cooling by free air convection
- Half encapsulated
- Built-in constant current limiting circuit
- 1U low profile 36mm
- All using 105℃ long life electrolytic capacitors
- LED indicator for power on
- 100% full load burn-in test
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 8.4A
- CURRENT RANGE
- 0 ~ 8.4A
- RATED POWER
- 100.8W
- RIPPLE & NOISE (max.)Note.2
- 120mVp-p
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±0.3%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 800ms, 50ms at full load
- HOLD UP TIME (Typ.)
- Please refer to page 3 Hold up Time( Load de-rating curve )
INPUT
- VOLTAGE RANGE CONTINUOUS
- 33.6 ~ 62.4VDC
- VOLTAGE RANGE 1 SEC.
- 28.8 ~ 67.2VDC
- EFFICIENCY (Typ.)
- 91%
- DC CURRENT (Typ.)
- 2.4A/48V
- INRUSH CURRENT (Typ.)
- 30A/48VDC
- INTERRUPTION OF VOLTAGE SUPPLY
- EN50155:2021-Comply with S1 level
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 13.8 ~ 16.2V Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ no derating with external base plate, TX class compliance
- WORKING HUMIDITY
- 5 ~ 95% RH non-condensing
- STORAGE TEMP.
- -40 ~ +85℃
- TEMP. COEFFICIENT
- ± 0.03%/℃ (0 ~ 50℃ )
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
- OPERATING ALTITUDE
- 5000 meters
SAFETY & EMC (Note 5)
- SAFETY STANDARDS
- IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
- WITHSTAND VOLTAGE
- I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8, BS EN/EN55035, light industry level, EAC TP TC 020
- RAILWAY STANDARD
- BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC ; BS EN/EN45545-2 for fire protection
OTHERS
- MTBF
- 2446.2K hrs min. Telcordia SR-332 (Bellcore) ; 254.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 161*68*36mm (L*W*H)
- PACKING
- 0.563Kg; 24pcs/14.5Kg/0.91CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 24,48,110VDC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSD-100-5 / -12)
- 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the RSD-100C-12 to supply 12V PLC or industrial control equipment from a 33.6~62.4V DC bus?
Yes, this converter is intended for constant-voltage 12V output from a 33.6~62.4V input range. With up to 8.4A and 100.8W available, it fits 12V PLC accessories, relays, I/O modules, and other control loads within that power budget.
Is the RSD-100C-12 a good fit for 48V telecom or automation cabinets that need 12V power?
Yes, nominal 48V DC systems fall within the 33.6~62.4V input range of this model. It converts that input to a regulated 12V output at up to 8.4A and 100.8W for 12V control and embedded equipment.
Can the RSD-100C-12 be used for 12V embedded systems in compact industrial enclosures?
Its 161.0 × 68.0 × 36.0 mm housing and 0.563 kg weight make it suitable where enclosure space is limited. It is intended for constant-voltage 12V loads up to 8.4A and 100.8W from a 33.6~62.4V DC source.
Is this converter appropriate for equipment exposed to wide temperature swings?
It operates from -40°C to +55°C without derating, and up to +70°C at 60% load by free air convection or at full load when mounted on an external base plate (EN50155 TX class). No IP rating is provided, so it is best used in a protected cabinet or enclosure if the installation environment includes dust, washdown, or direct weather exposure.
What are the main differences between the RSD-100C-12 and related 100W RSD-100 models?
Within the RSD-100 100W group, the 12V models are RSD-100B-12, RSD-100C-12, and RSD-100D-12, each rated at 100.8W and 8.4A. The matching 24V models are RSD-100B-24, RSD-100C-24, and RSD-100D-24 at 100.8W and 4.2A, and the 5V models are RSD-100B-5, RSD-100C-5, and RSD-100D-5 at 100W and 20A; the C version belongs to the 33.6~62.4V input family.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.