Mean Well SD-500L-24 DC-DC Converter - 500W - 19~72V in 24V out 21A

4:1 wide input range1.5~2KVAC isolation by models12V/0.25A auxiliary outputbuilt-in remote ON/OFF control and remote sense
SKU SD-500L-24
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

SD-500L-24 is the 24V output model of this series: rated current 21A, rated power 504W, typical efficiency 88%.

Features

  • DC input active surge current limiting
  • Wide 4:1~2:1 DC input range (24V: 19~72VDC, 96V:72~144VDC)
  • Protections: Short circuit / Overload / Over voltage / Over temperature / Input polarity(by fuse)
  • 2000VAC I/O Isolation
  • Forced air cooling by built-in DC fan with fan speed control function
  • Output OK Signal
  • Built-in remote ON-OFF control
  • Built-in remote sense function
  • 3 years warranty

Specifications

SD-500L-24Specifications from the official datasheet (2024-11-22 edition)

OUTPUT

DC VOLTAGE
24V
RATED CURRENT
21A
CURRENT RANGE
0 ~ 21A
RATED POWER
504W
RIPPLE & NOISE (max.)Note.2
150mVp-p
VOLTAGE ADJ. RANGE
23 ~ 30V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
SETUP, RISE TIME
500ms, 50ms at full load

INPUT

VOLTAGE RANGENote.5
19 ~ 72VDC
EFFICIENCY (Typ.)
88%
DC CURRENT (Typ.)
24.2A/19VDC 24.8A/24VDC 12A/48VDC
CURRENT (AT NO LOAD)
Max. 0.2A/48VDC
INRUSH CURRENT (Typ.)
60A/48VDC

PROTECTION

OVERLOAD
105 ~ 125% rated output power Protection type : Constant current limiting, shut down o/p voltage after about 5 sec., re-power on to recover
OVER VOLTAGE
30.8 ~ 35.2V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

REMOTE ON/OFF CONTROL
Please refer to function manual
OUTPUT OK SIGNAL
Open collector signal low when PSU turns on, max. sink current :10mA

ENVIRONMENT

WORKING TEMP.
-20 ~ +60℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.02%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC (Note 4)

SAFETY STANDARDS
IEC62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved, design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE
I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,6,8, BS EN/EN55035, light industry level, EAC TP TC 020

OTHERS

MTBF
1333.7K hrs min. Telcordia SR-332 (Bellcore) ; 196.3K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
215*115*50mm (L*W*H)
PACKING
1.15Kg; 12pcs/14.8Kg/0.9CUFT
Test conditions and notes6
  1. 1. All parameters NOT specially mentioned are measured at 48, 96VDC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

SD-500L-24 Mechanical Specification
Mechanical Specification
SD-500L-24 Block Diagram
Block Diagram
SD-500L-24 Derating Curve
Derating Curve
SD-500L-24 S D - 5 0 0 series
S D - 5 0 0 series
SD-500L-24 S D - 5 0 0 series (2)
S D - 5 0 0 series (2)
SD-500L-24 2.Output OK signal
2.Output OK signal
SD-500L-24 S D - 5 0 0 series
S D - 5 0 0 series
SD-500L-24 +Vo +Vo -Vo -Vo +V ADJ. CN3
+Vo +Vo -Vo -Vo +V ADJ. CN3

Downloads

FAQ

Can I use the SD-500L-24 for 24V PLC or industrial automation loads?

Yes, this unit provides constant-voltage 24V output for systems that need regulated 24V DC. It supports up to 21A and 504W, with a 19-72V input range for higher-voltage source systems.

Is the SD-500L-24 a fit for 24V embedded controllers or industrial PCs?

It can be used where the equipment requires constant 24V DC and the available source is within the 19-72V input range. Its 504W rating and 21A output capacity make it suitable for higher-power 24V embedded platforms and control hardware.

Can this model support 24V sensors, relays, and control accessories from a vehicle or battery bus?

Yes, provided the connected 24V loads stay within 21A and 504W. The 4:1 wide input range allows it to be used where the source varies across a 19-72V range but the downstream equipment still needs regulated 24V.

Can the SD-500L-24 be used in telecom or network equipment that runs on 24V DC?

It is appropriate for 24V telecom, network, or monitoring equipment that needs constant-voltage output up to 504W. The remote ON/OFF control and remote sense features also align with managed equipment applications.

How does the SD-500L-24 compare with the other SD-500L versions?

The SD-500L-24 is rated for 504W at 24V and 21A. In the same SD-500L family, the SD-500L-12 is 480W at 12V and 40A, while the SD-500L-48 is 504W at 48V and 10.5A. All three list the same 19-72V input range, 215.0 × 115.0 × 50.0 mm size, 1.15 kg weight, and -20°C to +60°C operating temperature.

Can the SD-500L-24 be used where ambient temperatures change a lot?

The specified operating temperature range is -20°C to +60°C. No IP rating is listed in the provided specs, so temperature capability is defined, but outdoor exposure protection is not.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8442725892395, "variants" :[{ "context":"default", "variant_id": 45712344056107, "sku":"SD-500L-24", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well SD-500L-24 DC-DC Converter - 500W - 19~72V in 24V out 21A
Mean Well

Mean Well SD-500L-24 DC-DC Converter - 500W - 19~72V in 24V out 21A

SD-500L-24 is the 24V output model of this series: rated current 21A, rated power 504W, typical efficiency 88%.

Features

  • DC input active surge current limiting
  • Wide 4:1~2:1 DC input range (24V: 19~72VDC, 96V:72~144VDC)
  • Protections: Short circuit / Overload / Over voltage / Over temperature / Input polarity(by fuse)
  • 2000VAC I/O Isolation
  • Forced air cooling by built-in DC fan with fan speed control function
  • Output OK Signal
  • Built-in remote ON-OFF control
  • Built-in remote sense function
  • 3 years warranty
View product