Overview
TS-3000-212C is the model of this series: typical efficiency 89%.
Features
- True sine wave output (THD<3%)
- High surge power up to 6000W
- High efficiency up to 92%
- Power ON-OFF switch
- Standby saving mode can be selectable
- Front panel indicator for operation status
- Thermostatically controlled cooling fan
- Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload / AC circuit breaker
- Support RS-232 communication (communication cable order No.: RJ11-RS232, sold sperately) Note.11
- 3 years warranty
Specifications
MODEL NO.
- MODEL NO.
- □ = B, C, D, G
OUTPUT
- RATED POWER (Typ.)
- 3000W
- MAXIMUM OUTPUT POWER (Typ.)
- 3450W for 180 sec. / 4500W for 10 sec. / surge power 6000W for 30 cycles
- AC VOLTAGE
- Factory setting set at 230VAC 200 / 220 / 230 / 240VAC selectable by setting button S.W
- FREQUENCYNote.10
- 50±0.1Hz 50/60Hz selectable by setting button S.W
- WAVEFORMNote.7
- True sine wave (THD<3%)
- AC REGULATION (Typ.)
- ±3%
- SAVING MODE (Typ.)
- Default disabled. Load≦5W will be changed to standby mode
- FRONT PANEL INDICATOR
- Battery voltage level, output load level, saving mode, fault and operation status
INPUT
- BAT. VOLTAGE
- 12V
- VOLTAGE RANGE (Typ.)Note.3,6
- 10.5 ~ 15VDC
- DC CURRENT (Typ.)Note.4
- 300A
- NO LOAD DISSIPATION (Typ.)
- ≦10W @ standby saving mode
- OFF MODE CURRENT DRAW (Typ.)
- ≦1mA
- EFFICIENCY (Typ.)Note.1
- 89%
- BATTERY TYPES
- Open & sealed lead acid battery
BATTERY INPUT PROTECTION
- FUSE
- 40A*12
- BAT. LOW ALARMNote.6
- 11.3V
- BAT. LOW SHUTDOWNNote.6
- 10.5V
- REVERSE POLARITY
- By internal fuse open
OUTPUT PROTECTION
- OVER TEMPERATURE
- 80℃ ± 5℃ Protection type : Shut down o/p voltage, re-power on to recover
- OUTPUT SHORT
- Protection type : Shut down o/p voltage, re-power on to recover
- OVER LOAD (Typ.)
- 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover
- CIRCUIT BREAKER
- AC output receptacle:15A
- GFCI PROCTECTION
- None
ENVIRONMENT
- WORKING TEMP.Note.2
- 0 ~ +40℃ @ 100% load ; 60℃ @ 50% load
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -30 ~ +70℃ / -22 ~ +158℉, 10 ~ 95% RH non-condensing
- VIBRATION
- 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- IEC62368-1 CB, EAC TP TC 004 approved; Design refer to BS EN/EN62368-1
- WITHSTAND VOLTAGE
- Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
- ISOLATION RESISTANCE
- Bat I/P - AC O/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, EAC TP TC 020
OTHERS
- CONTROL WIRINGNote.11
- RJ11 -RS232 (Option)
- MTBF
- 257.6K hrs min. Telcordia SR-332 (Bellcore) ; 33.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 466.8*283.5*100mm (L*W*H)
- PACKING
- 12.9Kg; 1pcs/14Kg/1.49CUFT
Test conditions and notes11
- 1.Efficiency is tested by 2100W, linear load at 13V, 26V, 52V input voltage.
- 2.Output derating capacity referenced by curve 1.
- 3.Input derating capacity referenced by curve 2.
- 4.DC current is tested by 3000W, linear load at 12V, 24V, 48V input voltage.
- 5.All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
- 6.The tolerance of each voltage value by models is:112/212→±0.5V;124/224→±1V;148/248→±2V.
- 7.THD is tested by 3000W, linear load at 13,26,52V input voltage.
- 8.Please do not turn on the inverter before start the engine if inverter connect to vehicle’s battery directly.
- 9.The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 10.Type F for 60Hz only.
- 11.The cable is used for the connection between TS-3000 and computer for software monitoring.
Technical drawings
Typical applications
- Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc.
Downloads
FAQ
What is the Mean Well TS-3000-212C designed for?
The TS-3000-212C is a DC-AC power inverter for applications that need 230V AC output from a DC source. Mean Well positions this model for home appliances, power tools, office equipment, portable equipment, vehicles, and yachts. Its true sine wave output makes it suitable for loads that need cleaner AC power.
What output power does the TS-3000-212C provide?
This model is rated for 3000W continuous output power. It also supports surge power up to 6000W, which helps with equipment that draws a higher startup load. That makes it a better fit for heavier-duty AC loads than lower-power inverter models.
Does the TS-3000-212C produce true sine wave output?
Yes. The TS-3000-212C provides true sine wave output with total harmonic distortion listed as less than 3%. This is an important differentiator for buyers who want cleaner AC output for sensitive or higher-quality equipment.
What is the output voltage of this inverter?
The TS-3000-212C is a 230V output inverter. Buyers should choose this model when their equipment requires 230V AC rather than a lower-voltage AC output. The product name and specification both identify it as a 230V unit.
What operating environment is this model intended for?
The stated operating temperature range for the TS-3000-212C is 0°C to 40°C at 100% load, extending to 60°C at 50% load. It uses a thermostatically controlled cooling fan to support operation within its designed temperature range. For buyers evaluating placement, this is an indoor-style operating range rather than an extreme-temperature specification.
Does the TS-3000-212C include monitoring or communication capability?
Yes, this model supports RS-232 communication. The required communication cable is listed as RJ11-RS232 and is sold separately. That can be useful for buyers who need status monitoring beyond the front-panel indicator.
What protection features are included on the TS-3000-212C?
The TS-3000-212C includes battery low alarm, battery low shutdown, over voltage, over temperature, output short, input polarity reverse, overload, and AC circuit breaker protection. These built-in protections are relevant for commercial and mobile power applications where load conditions can vary. The unit also includes a front-panel operation status indicator and selectable standby saving mode.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other TS-3000 Models
19 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.