💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well HRPG-600-24 Power Supply 648W 24V 27A

built-in active PFCPF > 0.95high efficiency up to 90%no load power consumption <0.5W~0.75W1U low profile
SKU HRPG-600-24
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

HRPG-600-24 is the 24V output model of this series: rated current 27A, rated power 648W, typical efficiency 88%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.93
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in cooling fan ON-OFF control
  • Built-in DC OK signal
  • Built-in remote ON-OFF control
  • Standby 5V@0.3A
  • Built-in remote sense function
  • No load power consumption<0.75W (Note.6)
  • Current sharing up to 2400W (3+1) (24V,36V,48V)
  • 5 years warranty

Specifications

HRPG-600-24Specifications from the official datasheet (2024-10-30 edition)

OUTPUT

DC VOLTAGE
24V
RATED CURRENT
27A
CURRENT RANGE
0 ~ 27A
RATED POWER
648W
RIPPLE & NOISE (max.)Note.2
150mVp-p
VOLTAGE ADJ. RANGE
21.6 ~ 28.8V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.2%
LOAD REGULATION
±0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load

INPUT

VOLTAGE RANGENote.4
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.93/230VAC PF>0.99/115VAC at full load
EFFICIENCY (Typ.)
88%
AC CURRENT (Typ.)
7.6A/115VAC 3.6A/230VAC
INRUSH CURRENT (Typ.)
35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1.2mA / 240VAC

PROTECTION

OVERLOAD
105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
30 ~ 34.8V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

5V STANDBY
5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.)
DC OK SIGNAL
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
REMOTE CONTROL
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
FAN CONTROL (Typ.)
Load 35±15% or RTH2≧50℃ Fan on

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC (Note 7)

SAFETY STANDARDS
UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/ EN61000-4-2,3,4,5,6,8,11, BS EN/ EN55024, BS EN/ EN61000-6-2, heavy industry level, EAC TP TC 020

OTHERS

MTBF
1142.5K hrs min. Telcordia SR-332 (Bellcore) ; 138.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
218*105*63.5mm (L*W*H)
PACKING
1.58Kg;8pcs/13.6Kg/1.34CUFT
Test conditions and notes8
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
  6. 6. No load power consumption<0.75W when RC+ & RC- (CN100 pin3,4) 0 ~ 0.8V or short.
  7. 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  8. 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

HRPG-600-24 Mechanical Specification
Mechanical Specification
HRPG-600-24 Block Diagram
Block Diagram
HRPG-600-24 Derating Curve
Derating Curve
HRPG-600-24 Function Manual
Function Manual
HRPG-600-24 H R P G - 6 0 0 series
H R P G - 6 0 0 series

Downloads

FAQ

Can I use the HRPG-600-24 for a 24V PLC or industrial automation panel?

Yes, if the panel uses a 24V constant voltage bus and the total demand stays within 648W and 27A. That aligns well with many industrial automation, PLC, HMI, and control cabinet applications built around 24V DC.

Is the HRPG-600-24 suitable for powering multiple 24V sensors, controllers, and accessories from one supply?

It is intended for 24V constant voltage systems and can deliver up to 27A with 648W total output. That makes it a strong fit for centralized 24V distribution where several industrial or embedded loads share one power source.

Can the HRPG-600-24 be used in industrial IT or communications equipment that requires 24V DC?

It can be used where the equipment is specified for constant 24V DC input and remains within 648W and 27A. The 218.0 x 105.0 x 63.5 mm housing should be checked against the available cabinet or rack space.

How does the HRPG-600-24 compare with the other HRPG-600 models?

The HRPG-600 range covers HRPG-600-3.3 at 396W, 3.3V, 120A; HRPG-600-5 at 600W, 5V, 120A; HRPG-600-7.5 at 600W, 7.5V, 80A; HRPG-600-12 at 636W, 12V, 53A; HRPG-600-15 at 645W, 15V, 43A; HRPG-600-24 at 648W, 24V, 27A; HRPG-600-36 at 630W, 36V, 17.5A; and HRPG-600-48 at 624W, 48V, 13A. Across these models, the mechanical size is 218.0 x 105.0 x 63.5 mm and the AC input range is 85-264VAC.

Can the HRPG-600-24 be used outside or in unconditioned industrial spaces?

The unit is rated for operation from -40C to +70C, with load derating according to the derating curve, so it supports a wide ambient temperature range. The specs provided here do not show an IP rating, which means outdoor suitability depends on the enclosure and site protection rather than the power supply by itself.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8343894917419, "variants" :[{ "context":"default", "variant_id": 45321029255467, "sku":"HRPG-600-24", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HRPG-600-24  Power Supply 648W 24V 27A
Mean Well

Mean Well HRPG-600-24 Power Supply 648W 24V 27A

HRPG-600-24 is the 24V output model of this series: rated current 27A, rated power 648W, typical efficiency 88%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.93
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in cooling fan ON-OFF control
  • Built-in DC OK signal
  • Built-in remote ON-OFF control
  • Standby 5V@0.3A
  • Built-in remote sense function
  • No load power consumption<0.75W (Note.6)
  • Current sharing up to 2400W (3+1) (24V,36V,48V)
  • 5 years warranty
View product