Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRPG-600-24 is the 24V output model of this series: rated current 27A, rated power 648W, typical efficiency 88%.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.93
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Built-in cooling fan ON-OFF control
- Built-in DC OK signal
- Built-in remote ON-OFF control
- Standby 5V@0.3A
- Built-in remote sense function
- No load power consumption<0.75W (Note.6)
- Current sharing up to 2400W (3+1) (24V,36V,48V)
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 27A
- CURRENT RANGE
- 0 ~ 27A
- RATED POWER
- 648W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 21.6 ~ 28.8V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.2%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.93/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 88%
- AC CURRENT (Typ.)
- 7.6A/115VAC 3.6A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 70A/230VAC
- LEAKAGE CURRENT
- <1.2mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 30 ~ 34.8V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- 5V STANDBY
- 5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.)
- DC OK SIGNAL
- PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
- REMOTE CONTROL
- RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
- FAN CONTROL (Typ.)
- Load 35±15% or RTH2≧50℃ Fan on
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 7)
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/ EN61000-4-2,3,4,5,6,8,11, BS EN/ EN55024, BS EN/ EN61000-6-2, heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 1142.5K hrs min. Telcordia SR-332 (Bellcore) ; 138.5K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 218*105*63.5mm (L*W*H)
- PACKING
- 1.58Kg;8pcs/13.6Kg/1.34CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 6. No load power consumption<0.75W when RC+ & RC- (CN100 pin3,4) 0 ~ 0.8V or short.
- 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the HRPG-600-24 for a 24V PLC or industrial automation panel?
Yes, if the panel uses a 24V constant voltage bus and the total demand stays within 648W and 27A. That aligns well with many industrial automation, PLC, HMI, and control cabinet applications built around 24V DC.
Is the HRPG-600-24 suitable for powering multiple 24V sensors, controllers, and accessories from one supply?
It is intended for 24V constant voltage systems and can deliver up to 27A with 648W total output. That makes it a strong fit for centralized 24V distribution where several industrial or embedded loads share one power source.
Can the HRPG-600-24 be used in industrial IT or communications equipment that requires 24V DC?
It can be used where the equipment is specified for constant 24V DC input and remains within 648W and 27A. The 218.0 x 105.0 x 63.5 mm housing should be checked against the available cabinet or rack space.
How does the HRPG-600-24 compare with the other HRPG-600 models?
The HRPG-600 range covers HRPG-600-3.3 at 396W, 3.3V, 120A; HRPG-600-5 at 600W, 5V, 120A; HRPG-600-7.5 at 600W, 7.5V, 80A; HRPG-600-12 at 636W, 12V, 53A; HRPG-600-15 at 645W, 15V, 43A; HRPG-600-24 at 648W, 24V, 27A; HRPG-600-36 at 630W, 36V, 17.5A; and HRPG-600-48 at 624W, 48V, 13A. Across these models, the mechanical size is 218.0 x 105.0 x 63.5 mm and the AC input range is 85-264VAC.
Can the HRPG-600-24 be used outside or in unconditioned industrial spaces?
The unit is rated for operation from -40C to +70C, with load derating according to the derating curve, so it supports a wide ambient temperature range. The specs provided here do not show an IP rating, which means outdoor suitability depends on the enclosure and site protection rather than the power supply by itself.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HRPG-600 Models
7 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HRPG-600-7.5 Power Supply 600W 7.5V 80A | 600W | 7.5V | 80A | View |
| Mean Well HRPG-600-5 Power Supply 600W 5V 120A | 600W | 5V | 120A | View |
| Mean Well HRPG-600-48 Power Supply 624W 48V 13A | 624W | 48V | 13A | View |
| Mean Well HRPG-600-36 Power Supply 630W 36V 17.5A | 630W | 36V | 17.5A | View |
| Mean Well HRPG-600-3.3 Power Supply 396W 3.3V 120A | 396W | 3.3V | 120A | View |
| Mean Well HRPG-600-15 Power Supply 645W 15V 43A | 645W | 15V | 43A | View |
| Mean Well HRPG-600-12 Power Supply 636W 12V 53A | 636W | 12V | 53A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.