Overview

RCP-1000-12-C is the 12V output model of this series: rated current 60A, rated power 720W, typical efficiency 81%.

RCP-1000 is a 1KW single output rack mountable front end AC/DC power supply This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in DC fan with fan speed control, working for the temperature up to 60℃. RCP-1000 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing (up to 8000W via three 19” rack shelves, RCP-1U), remote control, auxiliary power, alarm signal, etc.

Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 89%
  • Forced air cooling by built-in DC fan
  • Output voltage programmable
  • Built-in OR-ing diode, support hot swap (hot plug)
  • Active current sharing up to 3000W for one 19” rack shelf
  • Built-in I2C interface (RCP-1000-C models only)
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Optional conformal coating
  • 5 years warranty

Specifications

RCP-1000-12-CSpecifications from the official datasheet (2026-04-24 edition)

OUTPUT

DC VOLTAGE
12V
RATED CURRENT
60A
CURRENT RANGE
0 ~ 60A
RATED POWER
720W
RIPPLE & NOISE (max.)Note.2
150mVp-p
VOLTAGE ADJ. RANGE(SVR)
11.6 ~ 12.4V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
SETUP, RISE TIME
1000ms, 60ms/230VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC at full load

INPUT

VOLTAGE RANGENote.4
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
81%
AC CURRENT (Typ.)
8.5A/115VAC 4.5A/230VAC
INRUSH CURRENT (Typ.)
COLD START 50A
LEAKAGE CURRENT
<1.1mA / 230VAC

PROTECTION

OVERLOAD
105 ~ 125% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
13.2 ~ 16.2V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

AUXILIARY POWER
5V @ 0.3A
REMOTE ON-OFF CONTROL
By electrical signal or dry contact ON:short OFF:open
REMOTE SENSE
Compensate voltage drop on the load wiring up to 0.5V
OUTPUT VOLTAGE PROGRAMMABLE
Adjustment of output voltage is allowable to 90 ~ 110% of nominal output voltage. Please refer to the Function Manual.
DC OK SIGNAL
The isolated TTL signal out, Please refer to the Installation Manual
AC OK SIGNAL
The isolated TTL signal out, Please refer to the Installation Manual
OVER TEMP WARNING
Logic " High" for over temperature warning, Please refer to the Installation Manual, isolated signal

ENVIRONMENT

WORKING TEMP.
-20 ~ +60℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.02%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/ EN55032 (CISPR32)Class B
RadiatedBS EN/ EN55032 (CISPR32)Class B
Harmonic CurrentBS EN/ EN61000-3-2
Voltage FlickerBS EN/ EN61000-3-3
EMC IMMUNITY

BS EN/EN55035, BS EN/EN61000-6-2

ParameterStandardTest Level
ESDBS EN/ EN61000-4-2Level 3, 8KV air; Level 2, 4KV contact
RadiatedBS EN/ EN61000-4-3Level 3
EFT / BurstBS EN/ EN61000-4-4Level 3
SurgeBS EN/ EN61000-4-5Level 4, 4KV/Line-Earth; Level 3, 2KV/Line-Line
ConductedBS EN/ EN61000-4-6Level 3
Magnetic FieldBS EN/ EN61000-4-8Level 4
Voltage Dips and InterruptionsBS EN/ EN61000-4-11>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods

OTHERS

MTBF
840.8K hrs min. Telcordia SR-332 (Bellcore) ; 107.4K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
295*127*41mm (L*W*H)
PACKING
1.93Kg; 6pcs/12.6Kg/1.04CUFT
Test conditions and notes6
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  6. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

RCP-1000-12-C Block Diagram
Block Diagram
RCP-1000-12-C Static Characteristics
Static Characteristics
RCP-1000-12-C Derating Curve
Derating Curve
RCP-1000-12-C Function Manual
Function Manual
RCP-1000-12-C R C P - 1 0 0 0 series
R C P - 1 0 0 0 series
RCP-1000-12-C RCP-1000
RCP-1000
RCP-1000-12-C 3.1 RCP-1000-12
3.1 RCP-1000-12
RCP-1000-12-C 3.2 RCP-1000-24
3.2 RCP-1000-24
RCP-1000-12-C 3.3 RCP-1000-48
3.3 RCP-1000-48
RCP-1000-12-C Mechanical Specification
Mechanical Specification

Typical applications

  • Industrial automation
  • Distributed power architecture system
  • Wireless/telecommunication solution
  • Redundant power system
  • Electric vehicle charger system
  • Constant current source system

Downloads

FAQ

Can I use the RCP-1000-12-C for a 12V constant-current industrial load?

Yes, this version is the better fit when the application requires constant current behavior, because its operation mode is listed as constant current. It is rated at 12V, 60A, and 720W, so it is intended for high-power 12V systems that are specified around current-regulated output.

Is the RCP-1000-12-C appropriate for rack power systems in industrial or IT equipment?

It is positioned for rack-based power use, as the product is described as a 19 inch rack power supply with PFC and the enclosure is 295.0 × 127.0 × 41.0 mm. With 720W output at 12V and 60A, it suits higher-density DC power shelves more than low-power panel supply roles.

Can this model be used where multiple power modules need to share load?

Yes, the listed features include active current sharing up to 3000W, so it is intended for systems where multiple modules operate together. That is useful in higher-availability industrial or embedded platforms that need modular DC power capacity.

Would the RCP-1000-12-C fit high-current 12V test and validation setups?

It can fit high-current bench or validation environments that need regulated 12V power with programmable output voltage. The 60A output rating and 720W power level make it relevant for larger 12V loads than a typical general-purpose bench supply.

How does the RCP-1000-12-C differ from the other listed RCP models?

Among the listed siblings, the closest matches are RCP-1000-12 at 720W 12V 60A, RCP-1000-24 at 960W 24V 40A, and RCP-1000-48 at 1008W 48V 21A. Higher-capacity options include RCP-1600-12 at 1500W 12V 125A, RCP-1600-24 at 1608W 24V 67A, RCP-1600-48 at 1608W 48V 33.5A, RCP-1UT at 3000W 12V 60A, RCP-2000-12 at 1200W 12V 100A, RCP-2000-24 at 1920W 24V 80A, and RCP-2000-48 at 2016W 48V 42A; other listed siblings are RCP-1U, RCP-1UI, and RCP-MU. This model is the 720W, 12V, 60A constant-current member of that group.

Can the RCP-1000-12-C be used in exposed outdoor conditions?

The temperature range is -20°C to +60°C, so the unit is specified for a broad operating range. However, no IP rating is listed in the provided data, so outdoor exposure or sealed-enclosure performance is not established by these specs.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8343913529643, "variants" :[{ "context":"default", "variant_id": 45321175859499, "sku":"RCP-1000-12-C", "inventory_qty" : 2, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well RCP-1000-12-C AC-DC 19 inch rack power supply with PFC 1000W 60A
Mean Well

Mean Well RCP-1000-12-C AC-DC 19 inch rack power supply with PFC 1000W 60A

RCP-1000-12-C is the 12V output model of this series: rated current 60A, rated power 720W, typical efficiency 81%.

RCP-1000 is a 1KW single output rack mountable front end AC/DC power supply This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in DC fan with fan speed control, working for the temperature up to 60℃. RCP-1000 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing (up to 8000W via three 19” rack shelves, RCP-1U), remote control, auxiliary power, alarm signal, etc.

Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 89%
  • Forced air cooling by built-in DC fan
  • Output voltage programmable
  • Built-in OR-ing diode, support hot swap (hot plug)
  • Active current sharing up to 3000W for one 19” rack shelf
  • Built-in I2C interface (RCP-1000-C models only)
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Optional conformal coating
  • 5 years warranty

Typical applications

  • Industrial automation
  • Distributed power architecture system
  • Wireless/telecommunication solution
  • Redundant power system
  • Electric vehicle charger system
  • Constant current source system