Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
DDR-30G-5 is the 5V output model of this series: rated current 6A, rated power 30W, typical efficiency 85%.
DDR-30 series is a 30W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, ultra slim width (35mm), 4:1 ultra wide input voltage, -40~+85℃ wide operating temperature, 4KVdc I/O isolation, adjustable output voltage ( 10%) and full protective functions..etc. This series has two input options: 9~36V /18~75V and various output options: 5V / 12V / 15V / 24V and can be used for industrial control, security control, communication system and other fields. Suitable applications are DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable...etc.
Features
- Width only 35mm (2SU)
- 4:1 ultra wide input range
- -40~+85℃ wide working temperature
- No minimum load required
- DC output adjustable (±10%)
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- Protections: Short circuit / Overload / Over voltage / Input reverse polarity / Input under voltage protection
- 4KVdc I/O isolation(Reinforced isolation)
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 5V
- RATED CURRENT
- 6A
- CURRENT RANGE
- 0 ~ 6A
- RATED POWER
- 30W
- RIPPLE & NOISE (max.)Note.2
- 60mVp-p
- VOLTAGE ADJ. RANGE
- 4.5 ~ 5.5V
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.5%
- SETUP, RISE TIME
- 120ms, 85ms at full load
- HOLD UP TIME (Typ.)
- G-type: 7ms@24Vdc input
- EXTERNAL CAPACITANCE LOAD (Max.)
- 3300μF
INPUT
- VOLTAGE RANGENote.4
- 9 ~ 36Vdc
- EFFICIENCY (Typ.)
- 85%
- DC CURRENT (Typ.)
- 1.5A /24Vdc
- INRUSH CURRENT (Typ.)
- 15A /24Vdc
PROTECTION
- OVERLOAD
- 110 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 5.75 ~ 7V Protection type : Shut down o/p voltage, re-power on to recover
- REVERSE POLARITY
- By internal MOSFET, no damage, recovers automatically after fault condition removed
- UNDER VOLTAGE LOCKOUT
- 24Vin (G-type):Power ON≥9V , OFF≤8.5V 48Vin (L-type):Power ON≥18V , OFF≤17V
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 5 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 5 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 60℃ )
- VIBRATION
- Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
- OPERATING ALTITUDE
- 5000 meters
SAFETY & EMC
- SAFETY STANDARDS
- UL/IEC 62368-1 ,AS/NZS 62368.1 approved; Design refer to UL508
- WITHSTAND VOLTAGE
- I/P-O/P:4KVdc
- ISOLATION RESISTANCE
- I/P-O/P>100M Ohms / 500Vdc / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class B Radiated BS EN/EN55032 Class B Voltage Flicker BS EN/EN61000-3-3 ----- - EMC IMMUNITYNote 5
-
BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 3, 6KV contact; criteria A Radiated BS EN/EN61000-4-3 Level 3, 10V/m; criteria A EFT / Burst BS EN/EN61000-4-4 Level 3, 2KV; criteria A Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line; criteria A Conducted BS EN/EN61000-4-6 Level 3, 10V; criteria A Magnetic Field BS EN/EN61000-4-8 Level 4, 30A/m; criteria A
OTHERS
- MTBF
- 2780.3K hrs min. Telcordia SR-332 (Bellcore) ; 483.8K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 35*90*54.5mm (W*H*D)
- PACKING
- 0.12Kg;96pcs/12.5Kg/1.1CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at normal input (G:24Vdc, L:48Vdc), rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltage. Please check the derating curve for more details.
- 5. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Industrial control system
- Semiconductor fabrication equipment
- Factory automation
- Electro-mechanical
- Wireless network
- Telecom or datacom system
Downloads
FAQ
Can I use the DDR-30G-5 to power a 5V microcontroller or single-board computer from a 24V DC bus?
Yes. The DDR-30G-5 accepts 9-36V DC input and outputs 5V at up to 6A (30W), so a 24V bus is well within range. It provides enough current for Raspberry Pi-class SBCs, Arduino-based controllers, or custom microcontroller boards with attached peripherals in DIN rail-mounted automation panels.
Is the DDR-30G-5 suitable for providing isolated 5V power to USB-powered devices in an industrial cabinet?
Yes. The 4KVdc I/O isolation protects 5V USB devices from noise and transients on the DC bus. At 6A output, the DDR-30G-5 can supply multiple USB peripherals such as barcode scanners, touchscreens, or HID interfaces as long as total draw stays under 30W.
Can the DDR-30G-5 power 5V logic circuits in a vehicle or mobile equipment application?
Yes, as long as the vehicle supply stays within the 9-36V DC input range, which covers nominal 12V and 24V systems. The under-voltage lockout switches the unit off at 8.5V or below (on again at 9V or above), and derating may be needed at low input voltage. Within range it delivers a stable 5V at up to 6A for onboard data loggers, display screens, or communication interfaces in trucks, forklifts, or marine vessels.
Does the DDR-30G-5 require active cooling or ventilation?
The spec sheet lists no fan or forced-air cooling requirement for the DDR-30G-5. It is rated for a working temperature of -40°C to +85°C, but full 30W output is not available across that whole range: load must be derated at higher ambient temperatures according to the derating curve, so make sure the air inside the cabinet stays within those limits.
Can I use the DDR-30G-5 to power LED indicator panels or small display modules from a 12V solar battery?
Yes. A 12V solar battery (typical range 10-14.4V) is within the 9-36V input window, though the sheet notes that derating may be needed at low input voltage, so check the output-vs-input derating curve. The DDR-30G-5 provides 5V at up to 6A, which is sufficient for small LED matrix panels, OLED displays, or status indicator arrays in solar-powered kiosks or remote monitoring stations.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other DDR-30G Models
3 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well DDR-30G-24 DC-DC Converter - 30W - 9~36V in 24V out 1.25A | 30W | 24V | 1.25A | IP20 | View |
| Mean Well DDR-30G-12 DC-DC Converter - 30W - 9~36V in 12V out 2.5A | 30W | 12V | 2.5A | IP20 | View |
| Mean Well DDR-30G-15 DC-DC Converter - 30W - 9~36V in 15V out 2A | 30W | 15V | 2A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.