Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SKM10W8-03 is the 3.3V output model of this series: rated power 10W, typical efficiency 80%.
SKM10W8 and DKM10W8 series are 10W isolated and regulated module type DC-DC converter with DIP 1"x1" package. It features international standard pins, a high efficiency up to 90%, wide working temperature range -40~+90℃, 3KVdc I/P-O/P isolation voltage, Continuous-mode short circuit, overload, over voltage, input under voltage protection, etc. The models account for 8:1(9~75Vdc) ultra-wide input range, and various output voltage, 3.3V/5V/12V/15V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for all kinds of systems, such as industrial control, telecommunication field, distributed power architecture, and so on.
Features
- DIP 1"x1" package with industry standard pinout
- 8:1(9~75Vdc) ultra-wide input range
- Operating temperature range -40 ~ +90℃
- No minimum load required
- High efficiency up to 85%
- Protections: Short circuit (Continuous) / Overload / Over voltage / UVLO
- 3KVdc I/O isolation
- Remote ON/OFF control
- Trimming output (±10%)
- 3 years warranty
Specifications
MODEL SELECTION TABLE
- INPUT VOLTAGE (RANGE)
- Nominal 12V, 24V,36V,48V,72V (9 ~ 75V)
- INPUT CURRENT NO LOAD
- 10mA
- INPUT CURRENT FULL LOAD
- 213mA
- OUTPUT VOLTAGE
- 3.3V
- OUTPUT CURRENT
- 0~2500mA
- EFFICIENCY (TYP.)
- 80%
- CAPACITOR LOAD (MAX.)* For each output
- 2500μF
INPUT
- VOLTAGE RANGE
- 9~75Vdc
- SURGE VOLTAGE (100ms max.)
- 100Vdc
- FILTER
- Pi type
- PROTECTION
- Fuse recommended 3A Slow-Blow
OUTPUT
- VOLTAGE ACCURACY
- ±1.5%
- RATED POWER
- 10W
- RIPPLE & NOISENote.2
- 120mVp-p
- LINE REGULATIONNote.3
- ±1% for 3.3Vo model, ±0.5% for other models
- LOAD REGULATIONNote.4
- ±0.5%
- CROSS REGULATION
- ±5% @ 25% ~ 100% load only dual output
- SWITCHING FREQUENCY (Typ.)
- 440KHz
- EXTERNAL TRIM ADJ. RANGE (Typ.)
- ±10% (Single output model only)
PROTECTION
- SHORT CIRCUIT
- Continuous, automatic recovery
- OVERLOAD
- 110 ~ 200% rated output power Protection type : Recovers automatically after fault condition is removed
- OVER VOLTAGE
- Clamp by zener diode
- UNDER VOLTAGE LOCKOUT (Typ.) Start-up voltage
- 8.5Vdc
- UNDER VOLTAGE LOCKOUT (Typ.) Shutdown voltage
- 8.1Vdc
FUNCTION
- REMOTE CONTROL
- Power ON: R.C. ~ -Vin >3.5~75Vdc or open circuit ; Power OFF: R.C. ~ -Vin <1Vdc or short
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +90℃ (Refer to "Derating Curve")
- CASE TEMPERATURE
- +105℃ max.
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +125℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 73℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 3 ~ 5sec./260℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC ( Note.5)
- SAFETY STANDARDS
- EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVdc
- ISOLATION RESISTANCE
- I/P-O/P:1000M Ohms / 500Vdc / 25℃/ 70% RH
- ISOLATION CAPACITANCE (Typ.)
- 1000pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class A with additional components Radiated BS EN/EN55032 Class A with additional components - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, ±8KV air, Level 2, ±4KV contact Radiated Susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EFT/Bursts BS EN/EN61000-4-4 Level 1, 0.5KV Surge BS EN/EN61000-4-5 Level 2, 0.5KV Line-Line Conducted BS EN/EN61000-4-6 Level 2, 3V(e.m.f.)
OTHERS
- MTBF
- >2381Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 25.4*25.4*10.2mm (1*1*0.4 inch)
- CASE MATERIAL
- Five-side Metal shielded case
- PACKING
- 18g ; 12pcs/per tube, 600pcs/50 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input (48Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 0% to 100% rated load.
- 5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies."(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Telecom/datacom system
- Wireless network
- Industrial control facility
- Instrument
- Analyzer
- Detector
- Data switch
Downloads
::specification::
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.