Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
DKA30A-05 is the ±5V output model of this series: rated power 25W, typical efficiency 80%.
Features
- 2:1 wide input range
- 4:1 wide input range(option)
- 1500VDC I/O isolation
- Built-in EMI filter
- Trimming output(±10%)
- Remote ON-OFF control
- Protections: Short circuit / Overload
- Cooling by free air convection
- Six-sided shield metal case
- Epoxy encapsulated
- 100% burn-in test
- Approvals: FCC / EAC / CE / UKCA
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- ±5V
- CURRENT RANGE
- ±250 ~ ±2500mA
- RATED POWER
- 25W
- RIPPLE & NOISE (max.)Note.2
- 100mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- ±0.5%
- VOLTAGE ACCURACY
- ±2.0%
- SWITCHING FREQUENCY
- 100KHz min.
- EXTERNAL TRIM Adj. RANGE
- ±10%
INPUT
- VOLTAGE RANGE
- 9 ~ 18VDC
- EFFICIENCY (Typ.)
- 80%
- DC CURRENT
- Full load A: 3.2A B: 1.5A C: 0.77A No load A: 40mA B: 20mA C: 10mA
- FILTER
- Pi network
- PROTECTION
- Fuse recommended
PROTECTION (Note. 5)
- OVERLOAD
- 110 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +105℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03% / ℃(0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:1.5KVDC
- ISOLATION RESISTANCE
- I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 Class A, FCC part 15 Class A , EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A , EAC TP TC 020
OTHERS
- REMOTE CONTROL
- Power on: R.C ~-Vin > 4.5~5.5VDC or open, Power off : R.C~ -Vin <0.8VDC or short
- MTBF
- 100Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 50.8*50.8*21.0mm or 2"*2"*0.82" inch (L*W*H)
- PACKING
- 110g ; 5pcs/per tube, 140pcs/28 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input, rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
- 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
Technical drawings
Downloads
FAQ
Can I use the DKA30A-05 to power 5V industrial controllers from a 9-18VDC source?
Yes. It provides a regulated dual ±5V output from a 9-18VDC input and is rated at 25W with up to 2.5A per rail. That makes it suitable for low-power 5V controller or logic loads within that source range.
Is the DKA30A-05 suitable for embedded 5V electronics in vehicles or battery-based equipment?
It can fit applications that provide 9-18VDC input and need regulated ±5V rails. With 25W capacity and up to 2.5A per rail, it is intended for modest 5V embedded loads rather than larger 5V power systems.
Can this model be used for 5V auxiliary power in automation cabinets with low-voltage input?
Yes, if the cabinet source is within 9-18VDC and the auxiliary section needs a regulated ±5V output. The converter is rated for 25W and up to 2.5A per rail, which defines the load level it can support.
What is the difference between DKA30A-05, DKA30A-12, and DKA30A-15?
These models share the same 9-18VDC input range, 50.8 × 50.8 × 21.0 mm dimensions, -40°C to +85°C operating range, and 2-year warranty. The outputs differ: DKA30A-05 is 25W with ±5V at up to 2.5A per rail, DKA30A-12 is 30W with ±12V at up to 1.25A per rail, and DKA30A-15 is 30W with ±15V at up to 1A per rail.
Can the DKA30A-05 be used in hot or cold environments?
The specified operating range is -40°C to +85°C, with output derating at high temperatures per the derating curve. No IP rating is listed, so the provided specs do not identify it for outdoor or washdown exposure.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other DKA30 Models
8 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well DKA30C-15 DC-DC Converter - 30W - 36~72V in ±15V out 1A | 30W | 15V | 1A | IP20 | View |
| Mean Well DKA30C-12 DC-DC Converter - 30W - 36~72V in ±12V out 1.25A | 30W | 12V | 1.25A | IP20 | View |
| Mean Well DKA30C-05 DC-DC Converter - 25W - 36~72V in ±5V out 2.5A | 25W | 5V | 2.5A | IP20 | View |
| Mean Well DKA30B-15 DC-DC Converter - 30W - 18~36V in ±15V out 1A | 30W | 15V | 1A | IP20 | View |
| Mean Well DKA30B-12 DC-DC Converter - 30W - 18~36V in ±12V out 1.25A | 30W | 12V | 1.25A | IP20 | View |
| Mean Well DKA30B-05 DC-DC Converter - 25W - 18~36V in ±5V out 2.5A | 25W | 5V | 2.5A | IP20 | View |
| Mean Well DKA30A-15 DC-DC Converter - 30W - 9~18V in ±15V out 1A | 30W | 15V | 1A | IP20 | View |
| Mean Well DKA30A-12 DC-DC Converter - 30W - 9~18V in ±12V out 1.25A | 30W | 12V | 1.25A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.