Mean Well DKA30A-05 DC-DC Converter - 25W - 9~18V in ±5V out 2.5A

SKU DKA30A-05
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

DKA30A-05 is the ±5V output model of this series: rated power 25W, typical efficiency 80%.

Features

  • 2:1 wide input range
  • 4:1 wide input range(option)
  • 1500VDC I/O isolation
  • Built-in EMI filter
  • Trimming output(±10%)
  • Remote ON-OFF control
  • Protections: Short circuit / Overload
  • Cooling by free air convection
  • Six-sided shield metal case
  • Epoxy encapsulated
  • 100% burn-in test
  • Approvals: FCC / EAC / CE / UKCA
  • 2 years warranty

Specifications

DKA30A-05Specifications from the official datasheet (2024-08-02 edition)

OUTPUT

DC VOLTAGE
±5V
CURRENT RANGE
±250 ~ ±2500mA
RATED POWER
25W
RIPPLE & NOISE (max.)Note.2
100mVp-p
LINE REGULATIONNote.3
±0.5%
LOAD REGULATIONNote.4
±0.5%
VOLTAGE ACCURACY
±2.0%
SWITCHING FREQUENCY
100KHz min.
EXTERNAL TRIM Adj. RANGE
±10%

INPUT

VOLTAGE RANGE
9 ~ 18VDC
EFFICIENCY (Typ.)
80%
DC CURRENT
Full load A: 3.2A B: 1.5A C: 0.77A No load A: 40mA B: 20mA C: 10mA
FILTER
Pi network
PROTECTION
Fuse recommended

PROTECTION (Note. 5)

OVERLOAD
110 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

WORKING TEMP.
-40 ~ +85℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +105℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03% / ℃(0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
EAC TP TC 020/2011 approved
WITHSTAND VOLTAGE
I/P-O/P:1.5KVDC
ISOLATION RESISTANCE
I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 Class A, FCC part 15 Class A , EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A , EAC TP TC 020

OTHERS

REMOTE CONTROL
Power on: R.C ~-Vin > 4.5~5.5VDC or open, Power off : R.C~ -Vin <0.8VDC or short
MTBF
100Khrs min. MIL-HDBK-217F (25℃)
DIMENSION
50.8*50.8*21.0mm or 2"*2"*0.82" inch (L*W*H)
PACKING
110g ; 5pcs/per tube, 140pcs/28 tube/per carton
Test conditions and notes5
  1. 1.All parameters are specified at normal input, rated load, 25℃ 70% RH ambient.
  2. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
  3. 3.Line regulation is measured from low line to high line at rated load.
  4. 4.Load regulation is measured from 10% to 100% rated load.
  5. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.

Technical drawings

DKA30A-05 Mechanical Specification
Mechanical Specification
DKA30A-05 Packing
Packing

Downloads

FAQ

Can I use the DKA30A-05 to power 5V industrial controllers from a 9-18VDC source?

Yes. It provides a regulated dual ±5V output from a 9-18VDC input and is rated at 25W with up to 2.5A per rail. That makes it suitable for low-power 5V controller or logic loads within that source range.

Is the DKA30A-05 suitable for embedded 5V electronics in vehicles or battery-based equipment?

It can fit applications that provide 9-18VDC input and need regulated ±5V rails. With 25W capacity and up to 2.5A per rail, it is intended for modest 5V embedded loads rather than larger 5V power systems.

Can this model be used for 5V auxiliary power in automation cabinets with low-voltage input?

Yes, if the cabinet source is within 9-18VDC and the auxiliary section needs a regulated ±5V output. The converter is rated for 25W and up to 2.5A per rail, which defines the load level it can support.

What is the difference between DKA30A-05, DKA30A-12, and DKA30A-15?

These models share the same 9-18VDC input range, 50.8 × 50.8 × 21.0 mm dimensions, -40°C to +85°C operating range, and 2-year warranty. The outputs differ: DKA30A-05 is 25W with ±5V at up to 2.5A per rail, DKA30A-12 is 30W with ±12V at up to 1.25A per rail, and DKA30A-15 is 30W with ±15V at up to 1A per rail.

Can the DKA30A-05 be used in hot or cold environments?

The specified operating range is -40°C to +85°C, with output derating at high temperatures per the derating curve. No IP rating is listed, so the provided specs do not identify it for outdoor or washdown exposure.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8441844924715, "variants" :[{ "context":"default", "variant_id": 45707814142251, "sku":"DKA30A-05", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well DKA30A-05 DC-DC Converter - 25W - 9~18V in ±5V out 2.5A
Mean Well

Mean Well DKA30A-05 DC-DC Converter - 25W - 9~18V in ±5V out 2.5A

DKA30A-05 is the ±5V output model of this series: rated power 25W, typical efficiency 80%.

Features

  • 2:1 wide input range
  • 4:1 wide input range(option)
  • 1500VDC I/O isolation
  • Built-in EMI filter
  • Trimming output(±10%)
  • Remote ON-OFF control
  • Protections: Short circuit / Overload
  • Cooling by free air convection
  • Six-sided shield metal case
  • Epoxy encapsulated
  • 100% burn-in test
  • Approvals: FCC / EAC / CE / UKCA
  • 2 years warranty
View product