💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well DKA30B-15 DC-DC Converter - 30W - 18~36V in ±15V out 1A

SKU DKA30B-15
Log in to see price Trade pricing & online ordering for account holders
In stock
|

Overview

DKA30B-15 is the ±15V output model of this series: rated power 30W, typical efficiency 83%.

Features

  • 2:1 wide input range
  • 4:1 wide input range(option)
  • 1500VDC I/O isolation
  • Built-in EMI filter
  • Trimming output(±10%)
  • Remote ON-OFF control
  • Protections: Short circuit / Overload
  • Cooling by free air convection
  • Six-sided shield metal case
  • Epoxy encapsulated
  • 100% burn-in test
  • Approvals: FCC / EAC / CE / UKCA
  • 2 years warranty

Specifications

DKA30B-15Specifications from the official datasheet (2024-08-02 edition)

OUTPUT

DC VOLTAGE
±15V
CURRENT RANGE
±100 ~ ±1000mA
RATED POWER
30W
RIPPLE & NOISE (max.)Note.2
100mVp-p
LINE REGULATIONNote.3
±0.5%
LOAD REGULATIONNote.4
±0.5%
VOLTAGE ACCURACY
±2.0%
SWITCHING FREQUENCY
100KHz min.
EXTERNAL TRIM Adj. RANGE
±10%

INPUT

VOLTAGE RANGE
18 ~ 36VDC
EFFICIENCY (Typ.)
83%
DC CURRENT
Full load A: 3.2A B: 1.5A C: 0.77A No load A: 40mA B: 20mA C: 10mA
FILTER
Pi network
PROTECTION
Fuse recommended

PROTECTION (Note. 5)

OVERLOAD
110 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

WORKING TEMP.
-40 ~ +85℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +105℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03% / ℃(0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
EAC TP TC 020/2011 approved
WITHSTAND VOLTAGE
I/P-O/P:1.5KVDC
ISOLATION RESISTANCE
I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 Class A, FCC part 15 Class A , EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A , EAC TP TC 020

OTHERS

REMOTE CONTROL
Power on: R.C ~-Vin > 4.5~5.5VDC or open, Power off : R.C~ -Vin <0.8VDC or short
MTBF
100Khrs min. MIL-HDBK-217F (25℃)
DIMENSION
50.8*50.8*21.0mm or 2"*2"*0.82" inch (L*W*H)
PACKING
110g ; 5pcs/per tube, 140pcs/28 tube/per carton
Test conditions and notes5
  1. 1.All parameters are specified at normal input, rated load, 25℃ 70% RH ambient.
  2. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
  3. 3.Line regulation is measured from low line to high line at rated load.
  4. 4.Load regulation is measured from 10% to 100% rated load.
  5. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.

Technical drawings

DKA30B-15 Mechanical Specification
Mechanical Specification
DKA30B-15 Packing
Packing

Downloads

FAQ

Can I use the DKA30B-15 for analog I/O or control circuits that need ±15V rails?

Yes, this model fits analog I/O and control circuits designed for a regulated ±15V supply. It is rated for 30W total, up to 1A per rail, and 18-36VDC input.

Is the DKA30B-15 suitable for embedded data acquisition or instrumentation electronics?

It can be suitable for embedded acquisition or instrumentation electronics that require split ±15V rails. The converter provides a regulated ±15V output at up to 1A per rail, so the connected load must stay within the 30W rating.

Can this converter be used inside industrial equipment that already has an 18-36VDC supply?

Yes, if the existing source is within 18-36VDC and the downstream electronics need a regulated ±15V output. That makes it relevant for lower-power industrial and automation subsystems rather than higher-current output stages.

Does the DKA30B-15 support harsh operating temperatures or outdoor exposure?

The specified operating range is -40°C to +85°C (with output derating at high temperatures, see the derating curve), which supports use in equipment exposed to a broad temperature range. No IP rating is listed, so the published specs do not confirm outdoor use or direct exposure to water and dust.

What are the main differences between the DKA30B-15 and its sibling models?

The DKA30B-05 is rated for 25W with ±5V output at up to 2.5A per rail, the DKA30B-12 is rated for 30W with ±12V output at up to 1.25A per rail, and the DKA30B-15 is rated for 30W with ±15V output at up to 1A per rail. They are all dual-output converters in the same DKA30B family.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8441857081643, "variants" :[{ "context":"default", "variant_id": 45707954061611, "sku":"DKA30B-15", "inventory_qty" : 2, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well DKA30B-15 DC-DC Converter - 30W - 18~36V in ±15V out 1A
Mean Well

Mean Well DKA30B-15 DC-DC Converter - 30W - 18~36V in ±15V out 1A

DKA30B-15 is the ±15V output model of this series: rated power 30W, typical efficiency 83%.

Features

  • 2:1 wide input range
  • 4:1 wide input range(option)
  • 1500VDC I/O isolation
  • Built-in EMI filter
  • Trimming output(±10%)
  • Remote ON-OFF control
  • Protections: Short circuit / Overload
  • Cooling by free air convection
  • Six-sided shield metal case
  • Epoxy encapsulated
  • 100% burn-in test
  • Approvals: FCC / EAC / CE / UKCA
  • 2 years warranty
View product