Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
UHP-1500-230 is the model of this series: typical efficiency 95%.
UHP-1500 series is a 1500W single-output slim type power supply with 1U 41mm of low profile design. Adopting the full range 90~264Vac input, the entire series provides an output voltage line of 115, 230 and 380Vdc. In addition to the high efficiency up to 95.5%, that the whole series operates from -30℃ ~ 70℃ under air convection without fan. UHP-1500 has the complete protection functions and 5G anti-vibration capability; It is complied with the international safety regulations such as TUV BS EN/EN62368-1, UL62368-1. UHP-1500 series serves as a high performance power supply solution for various industrial and DC centralized bus applications.
Features
- High voltage output (115/230/380Vdc)
- Fanless and conduction-cooled design
- Slim and 1U Low profile (41mm)
- Built-in active PFC function
- DC 12V/0.4A auxiliary power
- Output voltage 50~120% and constant current 20~100% programmable(PV/PC)
- Protections: Short circuit / Over load / Over voltage / Over temperature
- Built-in remote ON-OFF control and DC OK signal
- Operating altitude up to 2000 meter (E type Note.6, Blank/PM type Note.7)
- LED indicator for power on
- Built-in PMBus or CANBus protocol
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE(DEFAULT)
- 230V
- CURRENT (FACTORY DEFAULT)
- 6.52A
- RATED CURRENT (Max.)
- 6.95A
- POWER (FACTORY DEFAULT)
- 1500W
- RATED POWER (Max.)Note.9
- 1501.2W
- RIPPLE & NOISE (Max.)Note.2
- 2300mVp-p
- FULL POWER VOLTAGE RANGE
- 216~260V
- VOLTAGE ADJ. RANGE
- By built-in potentiometer, SVR 170~260V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1800ms, 60ms/230VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC at 75% load 10ms/230VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 250 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≥0.95/230VAC at full load
- EFFICIENCY (Typ.)
- 95%
- AC CURRENT (Typ.)
- 8A/230VAC
- INRUSH CURRENT (Typ.)
- Cold start 60A/230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVER LOAD
- 105~125% rated output power Protection type : Constant current limiting, unit will shutdown after 5 sec, re-power on to recover.
- SHORT CIRCUIT
- Constant current limiting, unit will shutdown after 5 sec, re-power on to recover.
- OVER VOLTAGE
- 273 ~ 325V Protection type :Shut down O/P voltage,re-power on to recover
- OVER TEMPERATURE
- Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
FUNCTION
- OUTPUT VOLTAGE PROGRAMMABLE(PV)Note 5
- Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage Please refer to the Function Manual.
- OUTPUT CURRENT PROGRAMMABLE(PC)Note 5
- Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.
- REMOTE ON/OFF CONTROL
- Power ON : Short circuit Power OFF : Open circuit
- AUXILIARY POWER
- 12V @ 0.4A tolerance ±10%, ripple=150mVp-p
- DC-OK SIGNAL
- The TTL signal out, PSU turn on = 4.4 ~ 5.5V ; PSU turn off = -0.5 ~ 0.5V. Please refer to the Function Manual.
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃(Refer to “Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGENote 8
- OVC Ⅲ I/P-O/P:6KVDC I/P-FG:4KVDC O/P-FG:4KVDC
- ISOLATION RESISTANCENote 8
- I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32) Class B Radiated BS EN/EN55032 (CISPR32) Class A Harmonic Current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN61000-6-2
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 3 EFT / Burst BS EN/EN61000-4-4 Level 3 Surge BS EN/EN61000-6-2 2KV/Line-Line 4KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 3 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 597.3K hrs min. Telcordia SR-332 (Bellcore) ; 63.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 290*140*41mm (L*W*H)
- PACKING
- 2.51kg ; 6pcs/16.06kg/0.91CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance :includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. PV/PC functions when users do not use SVR.
- 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 8. Refer to derating curve.
Technical drawings
Typical applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipment or apparatus
- Test and measurement instrument
- Laser related machine
- Charging related equipment
- DC centralized bus(Lighting)
Downloads
Certificates4
Catalogues1
Other files1
FAQ
What is the Mean Well UHP-1500-230 designed for?
The UHP-1500-230 is a 1500W enclosed AC-DC power supply built for applications that need a regulated 230V DC output. Its slim 1U low-profile design and fanless conduction-cooled construction make it suitable for space-constrained industrial or equipment-integrated environments.
What are the key output specifications of the UHP-1500-230?
This model provides a 230V DC output with a 1500W power rating and a rated current of 6.95A. It is part of Mean Well's high-voltage UHP-1500 series, which is intended for applications requiring higher DC output voltage than standard low-voltage power supplies.
How is the UHP-1500-230 cooled?
The UHP-1500-230 uses a fanless, conduction-cooled design. This can be useful in applications where lower acoustic noise, reduced dust intake, or simpler thermal management is preferred compared with fan-cooled power supplies.
What protection features are included in the UHP-1500-230?
Mean Well lists short circuit, overload, over voltage, and over temperature protections for this model. These built-in protections help support safer operation in demanding equipment environments and add resilience against common fault conditions.
Can the UHP-1500-230 be used in harsh temperature conditions?
This model is rated for operation from -30°C to 70°C. That wide temperature range makes it better suited to industrial and enclosed equipment use than power supplies intended only for narrow indoor ambient conditions.
Does the UHP-1500-230 support remote control or monitoring-related functions?
Yes. The UHP-1500-230 includes built-in remote ON-OFF control and a DC OK signal, and its listed features also include remote capability. Mean Well also specifies programmable output voltage and constant current level (PV/PC) for applications that need more control flexibility.
What warranty comes with the Mean Well UHP-1500-230?
The UHP-1500-230 comes with a 5-year warranty. For B2B buyers, that longer warranty period can be an important factor when evaluating lifecycle cost and long-term equipment support.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other UHP-1500 Models
3 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well UHP-1500-380E Power Supply 1500W 380V Economic Model 3.95A | 1501W | 380V | 3.95A | View |
| Mean Well UHP-1500-380 Power Supply 1500W 380V 4.5A | 1500W | 380V | 4.5A | View |
| Mean Well UHP-1500-115 Power Supply 1500W 115V 13.05A | 1500.75W | 115V | 13.05A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.