Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLN-40H-12A is the 12V output model of this series: rated current 3.33A, rated power 40W, typical efficiency 86.5%.
Features
- Universal AC input / Full range (up to 305VAC)
- Built-in active PFC function
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- OCP point adjustable through output cable or internal potentiometer
- Fully isolated plastic case with IP64 level
- Class 2 power unit
- Three in one dimming function (1~10Vdc or PWM signal or resistance)
- Suitable for LED lighting, Industrial Lighting and moving sign applications
- Compliance to worldwide safety regulations for lighting
- Suitable for dry / damp locations or outdoor application
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- CONSTANT CURRENT REGIONNote.4
- 7.2 ~12V
- RATED CURRENT
- 3.33A
- RATED POWER
- 40W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGENote.6
- 10.8 ~ 13.5V
- CURRENT ADJ. RANGE
- Can be adjusted by internal potentiometer A type only
- CURRENT ADJ. RANGE
- 2 ~ 3.33A
- VOLTAGE TOLERANCENote.3
- ±2.5%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±2.0%
- SETUP, RISE TIMENote.7
- 500ms, 80ms at full load 230VAC / 115VAC
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
- EFFICIENCY (Typ.)
- 86.5%
- AC CURRENT (Typ.)
- 0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 50A(twidth=210μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVER CURRENTNote.4
- 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 15 ~ 21V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +50℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 40℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750, CSA C22.2 No. 250.0-08 , BS EN/EN 61347-1, BS EN/EN 61347-2-13 independent, IP64, EAC TP TC 004 approved ; design refer to UL60950-1, BS EN/EN60335-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧60% load) ; BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), EAC TP TC 020
OTHERS
- MTBF
- 3396.4K hrs min. Telcordia SR-332(Bellcore) ; 346.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 161*61.5*35mm (L*W*H)
- PACKING
- 0.35Kg;32pcs/12.2Kg/1.10CUFT
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 6. A type only.
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 11. This product is not suitable for LED lighting applications in China.(It is recommended to use the LPF/NPF/XLG/XLC/XLN series in China)
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Technical drawings
Downloads
FAQ
Can I use the HLN-40H-12A for 12V LED signage?
Yes, for 12V LED signage loads that match this driver’s 12V output, 3.33A output current, and 40W power rating. Signage is a typical application, and the IP64 enclosure helps in locations where dust and splashing water are a concern. When driving LEDs directly in constant-current mode, check that the load operates within the 7.2-12V constant current region.
Can the HLN-40H-12A be used with 12V LED strip lighting?
Yes. The HLN-40H-12A has a constant voltage + constant current characteristic, so it can supply a 12V constant-voltage strip (output adjustable 10.8-13.5V) at up to 3.33A, or drive LEDs directly in constant-current mode within the 7.2-12V region. Check the strip specification before pairing and keep the total connected load at or below 40W.
Is the HLN-40H-12A suitable for 12V accent or architectural lighting?
Yes, if the 12V lighting load fits this driver’s 40W rating and 3.33A output current, or operates within the 7.2-12V constant current region when driven directly. Its IP64 enclosure makes it appropriate for lighting applications that need protection beyond a basic indoor-only driver. Confirm the fixture or module is designed for these electrical ratings.
How much 12V LED strip can the HLN-40H-12A run?
This driver can supply up to 40W at 12V. To estimate maximum strip length, use 40W divided by your strip’s rated power per meter to get the maximum meters. Check your strip rated power per meter and keep the total load within 40W.
Can the HLN-40H-12A be used outdoors or in damp locations?
The HLN-40H-12A is rated IP64, so it is intended for environments where protection from dust and splashing water is needed. Its operating temperature range is -40°C to +50°C, which supports use in demanding conditions within that range. It should be selected only where IP64 protection is appropriate.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.