💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well HLN-40H-24A Power Supply 40W 24V - IP64, Adjustable 1.67A

fully isolated plastic caseIP64suitable for signage applicationsClass 2 power unit
SKU HLN-40H-24A
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

HLN-40H-24A is the 24V output model of this series: rated current 1.67A, rated power 40.1W, typical efficiency 88%.

Features

  • Universal AC input / Full range (up to 305VAC)
  • Built-in active PFC function
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • OCP point adjustable through output cable or internal potentiometer
  • Fully isolated plastic case with IP64 level
  • Class 2 power unit
  • Three in one dimming function (1~10Vdc or PWM signal or resistance)
  • Suitable for LED lighting, Industrial Lighting and moving sign applications
  • Compliance to worldwide safety regulations for lighting
  • Suitable for dry / damp locations or outdoor application
  • 3 years warranty

Specifications

HLN-40H-24ASpecifications from the official datasheet (2026-02-09 edition)

OUTPUT

DC VOLTAGE
24V
CONSTANT CURRENT REGIONNote.4
14.4 ~ 24V
RATED CURRENT
1.67A
RATED POWER
40.1W
RIPPLE & NOISE (max.)Note.2
150mVp-p
VOLTAGE ADJ. RANGENote.6
22 ~ 27V
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer A type only
CURRENT ADJ. RANGE
1 ~ 1.67A
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
SETUP, RISE TIMENote.7
500ms, 80ms at full load 230VAC / 115VAC
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load

INPUT

VOLTAGE RANGENote.5
90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
EFFICIENCY (Typ.)
88%
AC CURRENT (Typ.)
0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 50A(twidth=210μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER
12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC

PROTECTION

OVER CURRENTNote.4
95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
28 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.
-40 ~ +50℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 40℃)
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
UL8750, CSA C22.2 No. 250.0-08 , BS EN/EN 61347-1, BS EN/EN 61347-2-13 independent, IP64, EAC TP TC 004 approved ; design refer to UL60950-1, BS EN/EN60335-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧60% load) ; BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), EAC TP TC 020

OTHERS

MTBF
3396.4K hrs min. Telcordia SR-332(Bellcore) ; 346.2K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
161*61.5*35mm (L*W*H)
PACKING
0.35Kg;32pcs/12.2Kg/1.10CUFT
Test conditions and notes12
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Please refer to "DRIVING METHODS OF LED MODULE".
  5. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
  6. 6. A type only.
  7. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
  8. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  9. 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
  10. 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  11. 11. This product is not suitable for LED lighting applications in China.(It is recommended to use the LPF/NPF/XLG/XLC/XLN series in China)
  12. 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf

Technical drawings

HLN-40H-24A Mechanical Specification
Mechanical Specification
HLN-40H-24A Block Diagram
Block Diagram
HLN-40H-24A Derating Curve
Derating Curve
HLN-40H-24A Power Factor Characteristic
Power Factor Characteristic
HLN-40H-24A EFFICIENCY vs LOAD (48V Model)
EFFICIENCY vs LOAD (48V Model)
HLN-40H-24A H L N - 4 0 H series
H L N - 4 0 H series
HLN-40H-24A H L N - 4 0 H series (2)
H L N - 4 0 H series (2)
HLN-40H-24A DIMMING OPERATION(for B-type only)
DIMMING OPERATION(for B-type only)
HLN-40H-24A ※ Please DO NOT connect "DIM-" to "-V".
※ Please DO NOT connect "DIM-" to "-V".
HLN-40H-24A H L N - 4 0 H series
H L N - 4 0 H series
HLN-40H-24A H L N - 4 0 H series (2)
H L N - 4 0 H series (2)

Downloads

FAQ

Can I use the HLN-40H-24A for 24V sign lighting or light box applications?

Yes, this model is sized for 24V lighting loads up to 40.1W with 1.67A output, and signage is a typical application. It is a constant voltage + constant current LED driver, so the sign or light box load should match the 24V output, or the 14.4-24V constant current region when LEDs are driven directly.

Is the HLN-40H-24A a fit for 24V architectural accent lighting?

It can fit 24V accent or decorative lighting where the total load stays within 40.1W and 1.67A. The 90-305VAC input also makes it suitable for projects that need wide AC input tolerance.

Can I use this driver for 24V display or cabinet lighting in commercial spaces?

It can be used for 24V display, cabinet, or similar lighting loads that stay within the 40.1W maximum output. Its IP64-rated enclosure is useful for enclosed commercial lighting applications.

How do I estimate the maximum 24V LED strip length this driver can support?

Use the driver's 40.1W maximum output and divide it by your strip's rated watts per meter: 40.1W / strip W per meter = maximum theoretical length. Check your strip rated power per meter first, because the usable length depends on the strip's own load and this driver is rated at 24V, 1.67A, and 40.1W.

Is the HLN-40H-24A suitable for outdoor or wet locations?

It has an IP64 rating, which means protection against dust ingress and water splashes, so it can suit outdoor or damp-area lighting where splash resistance is needed. It is not rated for submersion, and its operating temperature range is -40 C to +50 C.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Other HLN-40H Models

16 other models
{ "id":8423768490283, "variants" :[{ "context":"default", "variant_id": 45635681714475, "sku":"HLN-40H-24A", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HLN-40H-24A Power Supply 40W 24V - IP64, Adjustable 1.67A
Mean Well

Mean Well HLN-40H-24A Power Supply 40W 24V - IP64, Adjustable 1.67A

HLN-40H-24A is the 24V output model of this series: rated current 1.67A, rated power 40.1W, typical efficiency 88%.

Features

  • Universal AC input / Full range (up to 305VAC)
  • Built-in active PFC function
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • OCP point adjustable through output cable or internal potentiometer
  • Fully isolated plastic case with IP64 level
  • Class 2 power unit
  • Three in one dimming function (1~10Vdc or PWM signal or resistance)
  • Suitable for LED lighting, Industrial Lighting and moving sign applications
  • Compliance to worldwide safety regulations for lighting
  • Suitable for dry / damp locations or outdoor application
  • 3 years warranty
View product