Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLN-40H-42B is the 42V output model of this series: rated current 0.96A, rated power 40.3W, typical efficiency 88.5%.
Features
- Universal AC input / Full range (up to 305VAC)
- Built-in active PFC function
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- OCP point adjustable through output cable or internal potentiometer
- Fully isolated plastic case with IP64 level
- Class 2 power unit
- Three in one dimming function (1~10Vdc or PWM signal or resistance)
- Suitable for LED lighting, Industrial Lighting and moving sign applications
- Compliance to worldwide safety regulations for lighting
- Suitable for dry / damp locations or outdoor application
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 42V
- CONSTANT CURRENT REGIONNote.4
- 25.2 ~ 42V
- RATED CURRENT
- 0.96A
- RATED POWER
- 40.3W
- RIPPLE & NOISE (max.)Note.2
- 300mVp-p
- VOLTAGE ADJ. RANGENote.6
- 40 ~ 46V
- CURRENT ADJ. RANGE
- Can be adjusted by internal potentiometer A type only
- CURRENT ADJ. RANGE
- 0.58 ~ 0.96A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.7
- 500ms, 80ms at full load 230VAC / 115VAC
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
- EFFICIENCY (Typ.)
- 88.5%
- AC CURRENT (Typ.)
- 0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 50A(twidth=210μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVER CURRENTNote.4
- 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 48 ~ 58V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +50℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 40℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750, CSA C22.2 No. 250.0-08 , BS EN/EN 61347-1, BS EN/EN 61347-2-13 independent, IP64, EAC TP TC 004 approved ; design refer to UL60950-1, BS EN/EN60335-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧60% load) ; BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), EAC TP TC 020
OTHERS
- MTBF
- 3396.4K hrs min. Telcordia SR-332(Bellcore) ; 346.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 161*61.5*35mm (L*W*H)
- PACKING
- 0.35Kg;32pcs/12.2Kg/1.10CUFT
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 6. A type only.
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 11. This product is not suitable for LED lighting applications in China.(It is recommended to use the LPF/NPF/XLG/XLC/XLN series in China)
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Technical drawings
Downloads
FAQ
Can the HLN-40H-42B be used for 42V illuminated sign projects?
Yes, it is suitable for 42V sign lighting, including constant-current loads within the 25.2-42V CC region. It delivers up to 0.96A and 40.3W, and signage is a typical application.
Is this driver appropriate for 42V display or cabinet lighting?
It can be used for 42V display or cabinet lighting loads that need up to 0.96A. The fixture must stay below the 40.3W maximum output, and within the 25.2-42V constant-current region when the LEDs are driven directly.
Can I pair the HLN-40H-42B with a 42V constant-current LED strip?
Yes, if the strip operates within the 25.2-42V constant-current region and needs no more than 0.96A. The driver also has a constant-voltage mode at 42V, so both the strip voltage range and current requirement need to line up with those specs.
Is the HLN-40H-42B suitable for wet or outdoor environments?
It is rated IP64, which means protection against dust and splashing water rather than full submersion. That makes it appropriate for many damp or sheltered outdoor lighting environments, and it is rated to operate from -40°C to +50°C.
How much 42V LED strip load can this driver support?
The total available output is 40.3W. To estimate supported strip length, divide 40.3W by your strip's rated watts per meter, and verify the strip is a 42V product whose total current stays within 0.96A (or, for constant-current operation, within the 25.2-42V region).
How does the HLN-40H-42B compare with nearby HLN-40H voltage options?
In the HLN-40H range, the adjacent higher-voltage models are 36V at 1.12A, 42V at 0.96A, 48V at 0.84A, and 54V at 0.75A, all around 40W. The HLN-40H-42B is the 42V dimmable option at 40.3W and 0.96A.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HLN-40H Models
16 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.