💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well HLN-40H-54A Power Supply 40W 54V - IP64, Adjustable 750mA

fully isolated plastic caseIP64suitable for signage applicationsClass 2 power unit
SKU HLN-40H-54A
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

HLN-40H-54A is the 54V output model of this series: rated current 0.75A, rated power 40.5W, typical efficiency 89%.

Features

  • Universal AC input / Full range (up to 305VAC)
  • Built-in active PFC function
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • OCP point adjustable through output cable or internal potentiometer
  • Fully isolated plastic case with IP64 level
  • Class 2 power unit
  • Three in one dimming function (1~10Vdc or PWM signal or resistance)
  • Suitable for LED lighting, Industrial Lighting and moving sign applications
  • Compliance to worldwide safety regulations for lighting
  • Suitable for dry / damp locations or outdoor application
  • 3 years warranty

Specifications

HLN-40H-54ASpecifications from the official datasheet (2026-02-09 edition)

OUTPUT

DC VOLTAGE
54V
CONSTANT CURRENT REGIONNote.4
32.4 ~ 54V
RATED CURRENT
0.75A
RATED POWER
40.5W
RIPPLE & NOISE (max.)Note.2
300mVp-p
VOLTAGE ADJ. RANGENote.6
49 ~ 58V
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer A type only
CURRENT ADJ. RANGE
0.45 ~ 0.75A
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
SETUP, RISE TIMENote.7
500ms, 80ms at full load 230VAC / 115VAC
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load

INPUT

VOLTAGE RANGENote.5
90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
EFFICIENCY (Typ.)
89%
AC CURRENT (Typ.)
0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 50A(twidth=210μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER
12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC

PROTECTION

OVER CURRENTNote.4
95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
59 ~ 68V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.
-40 ~ +50℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 40℃)
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
UL8750, CSA C22.2 No. 250.0-08 , BS EN/EN 61347-1, BS EN/EN 61347-2-13 independent, IP64, EAC TP TC 004 approved ; design refer to UL60950-1, BS EN/EN60335-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧60% load) ; BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), EAC TP TC 020

OTHERS

MTBF
3396.4K hrs min. Telcordia SR-332(Bellcore) ; 346.2K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
161*61.5*35mm (L*W*H)
PACKING
0.35Kg;32pcs/12.2Kg/1.10CUFT
Test conditions and notes12
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Please refer to "DRIVING METHODS OF LED MODULE".
  5. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
  6. 6. A type only.
  7. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
  8. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  9. 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
  10. 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  11. 11. This product is not suitable for LED lighting applications in China.(It is recommended to use the LPF/NPF/XLG/XLC/XLN series in China)
  12. 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf

Technical drawings

HLN-40H-54A Mechanical Specification
Mechanical Specification
HLN-40H-54A Block Diagram
Block Diagram
HLN-40H-54A Derating Curve
Derating Curve
HLN-40H-54A Power Factor Characteristic
Power Factor Characteristic
HLN-40H-54A EFFICIENCY vs LOAD (48V Model)
EFFICIENCY vs LOAD (48V Model)
HLN-40H-54A H L N - 4 0 H series
H L N - 4 0 H series
HLN-40H-54A H L N - 4 0 H series (2)
H L N - 4 0 H series (2)
HLN-40H-54A DIMMING OPERATION(for B-type only)
DIMMING OPERATION(for B-type only)
HLN-40H-54A ※ Please DO NOT connect "DIM-" to "-V".
※ Please DO NOT connect "DIM-" to "-V".
HLN-40H-54A H L N - 4 0 H series
H L N - 4 0 H series
HLN-40H-54A H L N - 4 0 H series (2)
H L N - 4 0 H series (2)

Downloads

FAQ

Can I use the HLN-40H-54A for LED signage modules that need constant current?

Yes, if the LED load operates within the 32.4-54V constant-current region and up to 0.75A. This model is rated 40.5W at 54V, and signage is a typical application. It has a constant voltage + constant current characteristic, so it can also supply 54V constant-voltage loads.

Is the HLN-40H-54A suitable for a 54V linear lighting fixture?

It can be suitable for a 54V linear fixture, either driven directly in constant-current mode within the 32.4-54V region or supplied at 54V in constant-voltage mode, at up to 0.75A. The driver delivers up to 40.5W, so the fixture load needs to stay within that rating. Check the fixture's electrical rating before matching it to this driver.

Can this driver power a high-voltage LED strip run?

Yes, a 54V strip can be run: the driver works in constant-voltage mode at 54V (adjustable 49-58V) or in constant-current mode within 32.4-54V, at up to 0.75A. For length, use the power limit: 40.5W divided by your strip's rated watts per meter equals the maximum estimated run length. Check your strip rated power per meter before sizing.

Is the HLN-40H-54A a good fit for outdoor sign lighting?

It is suited to locations where IP64 protection is appropriate, because the case is rated IP64 and the operating temperature range is -40°C to +50°C. That means it is intended for dusty or splash-prone environments rather than full water immersion. Match the enclosure and site conditions to an IP64 product.

Can I use this for architectural accent lighting in a damp area?

Yes, if the lighting load needs up to 0.75A at 54V, or operates within the 32.4-54V constant-current region, and the environment fits an IP64 rating. The IP64-rated enclosure is useful where a compact protected driver is needed. It should only be paired with loads that match its 40.5W, 54V output.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Other HLN-40H Models

16 other models
{ "id":8423775240491, "variants" :[{ "context":"default", "variant_id": 45635690168619, "sku":"HLN-40H-54A", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HLN-40H-54A Power Supply 40W 54V - IP64, Adjustable 750mA
Mean Well

Mean Well HLN-40H-54A Power Supply 40W 54V - IP64, Adjustable 750mA

HLN-40H-54A is the 54V output model of this series: rated current 0.75A, rated power 40.5W, typical efficiency 89%.

Features

  • Universal AC input / Full range (up to 305VAC)
  • Built-in active PFC function
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • OCP point adjustable through output cable or internal potentiometer
  • Fully isolated plastic case with IP64 level
  • Class 2 power unit
  • Three in one dimming function (1~10Vdc or PWM signal or resistance)
  • Suitable for LED lighting, Industrial Lighting and moving sign applications
  • Compliance to worldwide safety regulations for lighting
  • Suitable for dry / damp locations or outdoor application
  • 3 years warranty
View product