Overview
HRP-300-48 is the 48V output model of this series: rated current 7A, rated power 336W, typical efficiency 89%.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Built-in constant current limiting circuit
- 1U low profile 41mm
- Built-in cooling fan ON-OFF control
- Built-in DC OK signal
- Built-in remote sense function
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 7A
- CURRENT RANGE
- 0 ~ 7A
- RATED POWER
- 336W
- RIPPLE & NOISE (max.)Note.2
- 250mVp-p
- VOLTAGE ADJ. RANGE
- 40.8 ~ 55.2V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.2%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 89%
- AC CURRENT (Typ.)
- 3.5A/115VAC 1.8A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 70A/230VAC
- LEAKAGE CURRENT
- <1.2mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- DC OK SIGNAL
- PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V
- FAN CONTROL (Typ.)
- Load 35±15% or RTH2≧50℃ Fan on
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/ EN61000-4-2,3,4,5,6,8,11, BS EN/ EN55035, BS EN/ EN61000-6-2, heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 1487.1K hrs min. Telcordia SR-332 (Bellcore) ; 200.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 199*105*41mm (L*W*H)
- PACKING
- 0.95Kg;15pcs/15.3Kg/0.83CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the HRP-300-48 for a 48V industrial or automation system?
Yes, this model provides constant voltage 48V output at up to 7A and 336W. It is intended for equipment that specifically requires a 48V DC bus, not lower-voltage 12V, 15V, 24V, or 36V loads.
Is the HRP-300-48 a fit for 48V communications or embedded equipment?
It can be a fit where the equipment needs regulated 48V DC and the total load remains within 7A and 336W. The 85-264VAC input range also supports use across different AC supply conditions.
Would the HRP-300-48 work for a centralized 48V DC subsystem in a cabinet or enclosure?
Yes, as long as the combined 48V load stays within 336W and 7A. Its 199.0 × 105.0 × 41.0 mm size and 0.95 kg weight can be useful where enclosure space is constrained.
Is the HRP-300-48 suitable for outdoor use or wide temperature conditions?
The specified operating range is -40°C to +70°C, with output derating at higher ambient temperatures per the derating curve. No IP rating is listed in the provided data, so it should be used in indoor or protected enclosures rather than exposed outdoor locations.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HRP-300 Models
3 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HRP-300-7.5 Power Supply 300W 7.5V 40A | 300W | 7.5V | 40A | View |
| Mean Well HRP-300-5 Power Supply 300W 5V 60A | 300W | 5V | 60A | View |
| Mean Well HRP-300-36 Power Supply 324W 36V 9A | 324W | 36V | 9A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.